Siemens APT Relays – Maintenance of high-voltage relays

Create Date: 2024-8-30 12:03:23|Source: APT/Siemens Shanghai Ergong

1. Regular cleaning: The relay needs to be cleaned regularly with dust and dirt to keep its surface clean and smooth. It can be cleaned with a clean cloth or brush, and detergents containing acids and bases should be avoided.

2. Check the wiring: The wiring of the relay needs to be fastened firmly and in good contact. You can regularly check whether the wiring is loose or rusty, and deal with it in time.

3. Check the contacts: The contacts of the relay are the core part of the relay, and it is necessary to regularly check whether the contacts are sintered, oxidized or corroded. The contact surface can be gently wiped with fine sandpaper or a wire brush to remove dirt and oxides from the surface.

4. Regular maintenance: During the use of the relay, there will be problems such as poor contact and burnt contact, which need to be regularly overhauled and replaced. It can be regularly overhauled and replaced according to the service life of the relay, the environment in which it is used, etc.

5. Avoid overload: When using the relay, it is necessary to avoid exceeding its rated current and voltage range, so as not to cause overload and damage.
Siemens APT Relays – Maintenance of high-voltage relays

More on that
Siemens APT Relays - What are the relays that burn out? Siemens APT Relays - What are the relays that burn out?

1. The position of the auxiliary contact is not suitable. After the switch has been tripped, the mechanical part has moved, worn phenomenon, resulting in the auxiliary contact position offset to the correct position, in the protection action tripping, when the auxiliary contact is not disconnected, the outlet electrical appliances, electrical appliances, relays have returned, and it is ...

APT won the 2014 Top Ten Cutting-edge Enterprises in China's Automation Field APT won the 2014 Top Ten Cutting-edge Enterprises in China's Automation Field

On April 22, 2015, the "2015 China Automation Industry Annual Conference and the 10th China Automation Industry Century Event" sponsored by the Chinese Association of Automation was held in Beijing. At the conference, APT won the "2014 Top Ten New Enterprises in China's Automation Field" award, which was awarded by APT last year.

Siemens APT Relays - Precautions for the use of solid state relays Siemens APT Relays - Precautions for the use of solid state relays

1. When choosing the solid state used in the printed circuit board with small current specifications, because the lead terminal is made of high thermal conductivity material, the welding should be carried out under the condition that the temperature is less than 250 °C and the time is less than 10S.

Siemens APT - ALS series limit switch FAQ Siemens APT - ALS series limit switch FAQ

1. What are the installation methods of ALS limit switches? Usually the limit switch is divided into front of the board installation or board back installation, all of which are installed by screws. 2. What are the different modes of limit switch action? According to the action mode of the limit switch head, it is divided into ...

Siemens APT current transformer – the difference between the ratio on a current transformer and the ratio on a watt-hour meter Siemens APT current transformer – the difference between the ratio on a current transformer and the ratio on a watt-hour meter

1. Differences in use The conversion ratio of the current transformer is inconsistent with the transformation ratio of the ammeter, which will lead to the inability to use the displayed value of the ammeter directly, and the proportional conversion must be carried out; If the transformer of ratio 5 is used on the meter of ratio 1, the secondary current of CT will generally exceed 1A, so that the transformer of 5 is used on a meter of 1 ratio. Than 1 ...

Siemens APT relay - the cause and solution of the fault of the high-voltage relay Siemens APT relay - the cause and solution of the fault of the high-voltage relay

1. Some common faults of high-voltage relay coils 1. The common fault cause of the coil is often disconnected: whether the ultrasonic wave is used to clean the high-voltage relay, or whether the overvoltage is added to the coil will also promote the probability of the coil being disconnected. 2 ...

Siemens APT – X-Series Control Box FAQ Siemens APT – X-Series Control Box FAQ

1. The control box is made of ABS and PC, which material has better flame retardant performance? ABS has good flame retardant performance. 2. What are the certifications for the control box? 3C & CE (for unperforated control box only) 3. What is the color of the grey cabinet of the control box? Work...

Siemens APT Relays – The difference between solid state relays and intermediate relays Siemens APT Relays – The difference between solid state relays and intermediate relays

First, the solid-state relay has no contacts and coils in the structure, which can be opened and closed at a high frequency and will not produce sparks, and has a long service life; Second, the intermediate relay is generally only used for the control loop, and cannot work with load, and will make a "pop" sound when it is sucked in; ...

Siemens APT Relays - the main product technical parameters of relays Siemens APT Relays - the main product technical parameters of relays

(1) Rated working voltage: refers to the voltage required by the coil when the relay is working normally. Depending on the type of relay, it can be either AC voltage or DC voltage. (2) DC resistance: refers to the DC resistance of the coil in the relay, which can be measured by a multimeter. ...

Siemens APT Relays - What are the classifications of high and low voltage relays? Siemens APT Relays - What are the classifications of high and low voltage relays?

1) Electromagnetic relay: an electrical relay that works by using the suction force generated by the circuit in the input circuit between the electromagnet core and the armature. 2) Solid relay: refers to a kind of relay in which electronic components perform their functions without mechanical motion components, and the input and output are isolated. ...

Siemens APT current transformer - how to see the multiple of the current transformer Siemens APT current transformer - how to see the multiple of the current transformer

1. Most of the multiple values can be seen from the nameplate attached to the instrument, which will show the style of the value/value, which can be known by dividing the previous value by dividing the back value when calculating the standard core-piercing turns. If the actual number of turns of the grommet does not conform to the standard, then the multiple should be ...

Siemens APT – PB1 Series FAQs Siemens APT – PB1 Series FAQs

1. What are the installation methods of PB1 button? PB1S and PB1L are fastened with metal screws, and PB1J and PL1 are fastened with plastic nuts. 2. PB1 series pushbuttons can be assembled with up to several sets of contact modules as standard 2*3=6 3. PB1S shell ...

Siemens APT Relays – Functions of High Voltage Relays Siemens APT Relays – Functions of High Voltage Relays

1. Control switch: The high-voltage relay can open or close the high-voltage circuit to achieve the purpose of controlling the work of the equipment. 2. Protection circuit: The high-voltage relay can monitor the current, voltage, temperature and other parameters inside the high-voltage circuit, and automatically cut off the circuit when the circuit is abnormal.

Siemens APT current transformer – wiring method of current transformer Siemens APT current transformer – wiring method of current transformer

1. The single wiring mode can only feedback the status of single-phase current. 2. Three-phase complete star wiring, usually used in transformer differential protection wiring. 3. The two-phase incomplete star wiring method is used frequently in daily work. 4. The two phases ...

Siemens APT Relays – The action of high and low voltage relays and how to adjust the low voltage side Siemens APT Relays – The action of high and low voltage relays and how to adjust the low voltage side

1. Disconnect the control power supply: Before making the low-voltage terminal contact adjustment, the control power supply should be disconnected first to avoid the current directly or indirectly passing through the relay contact, and avoid electric shock or damage to the relay. 2. Open the relay cover: Open the relay cover, you can see the inside of the relay.

Siemens APT current transformers – measures to reduce errors Siemens APT current transformers – measures to reduce errors

The excitation current is the main cause of the error of the current transformer, so reducing the excitation current can reduce the error (1) The core is made of materials with high permeability, because the magnetic properties of the core not only affect the ratio difference and angular difference, but also affect the saturation multiple. (2) Increase the cross-section of the iron core and shorten the magnetic circuit.

Siemens APT Relays – Principles and characteristics of photorelays Siemens APT Relays – Principles and characteristics of photorelays

When the input quantity (such as voltage, current, temperature, etc.) reaches the specified value, the controlled output circuit is turned on or off an electrical appliance. It can be divided into two categories: electrical (such as current, voltage, frequency, power, etc.) relays and non-electrical (such as temperature, pressure, speed, etc.) relays. With action ...

Siemens APT Relays – How to Choose Relays? Siemens APT Relays – How to Choose Relays?

1. The type and series of relay selection First of all, the type of relay is selected according to the work requirements of the object to be controlled or protected, and then the appropriate series is selected according to the sensitivity or accuracy requirements. When choosing a series, you should also pay attention to the compatibility of the relay with the system. (1) ...

Siemens APT relay - the main structural features of high and low voltage relays Siemens APT relay - the main structural features of high and low voltage relays

1. Electromagnet: The electromagnet of high and low voltage relay is usually composed of two parts: coil and core. When the high and low voltage relay inputs the electrical signal, the electromagnet coil will generate electromagnetic force, drive the iron core, and realize the on/off control of the relay. 2. Contact group: The contact group is a high and low voltage relay control ...

TL series police lights frequently asked questions TL series police lights frequently asked questions

1. How many light sources are there for the TL-70 police light? There are 3 types, namely LED, incandescent and xenon. 2. What are the colors of the TL-70 police light? There are 5 types, which are red, yellow, green, blue, and white. 3. What are the types of TL-70 police lights? 3 ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top