Siemens APT - AD16 series indicator frequently asked questions

Create Date: 2024-8-30 12:03:23|Source: APT/Siemens Shanghai Ergong

1. Why does the indicator light still glow after the control power supply has been disconnected?

This situation is caused by the presence of interference voltage, and this problem can be solved by ordering our anti-interference indicator light

2. What are the operating hours of the AD16 series indicators?

>30,000 hours

3. Can the AD16-22 series indicators be produced in ultra-short versions?

Due to heat dissipation, ultra-short types cannot be produced with DC220V and above voltages

4. Is there an indicator with IP67 protection?

The AD16-35KTKA and AD16-60KTKA indicators are IP67 rated

5. What is the sound frequency of the AD16 series buzzer?

  AD16-16M:2300Hz±300 / AD16-22M:4000Hz±300 / AD16-30M:3300Hz±300

6. Does the AD16-16 series have a flash buzzer?

Yes, there are two types: plug-in type and screw wiring type

7. How to wire the AD16-22D bi-color lamp?

"X0 is the public end, regular red and green, X0X1 controls the red light, and X0X2 controls the green light. When using AC specifications, pay attention to the directionality of the wiring to avoid burning. "

8. Can the AD16-22SM flash buzzer be controlled separately from sound and light?

Yes, the regular model has a rear endnote-V, X0 is the common end, X0X1 controls the flash, and X0X2 controls the sound

9. Can the AD16 monomer indicator achieve three light emitting colors?

"AD16-22D/rg two-color lamp can be realized, if the red light and green light of the two-color lamp are energized at the same time, the red-green-yellow or red-green-orange color can appear after color mixing"

10. Can the AD16-22M buzzer be waterproof?

No, because the sound needs to be transmitted through the sound hole in the end cap of the buzzer

11. What does FD stand for?

FD stands for discharge lamp that can be installed in a capacitor bank, and AC/DC products are selected for use in capacitor discharge circuits. It has now been cancelled and can be replaced directly with a DC specification indicator

12. Can the DC voltage of the AD16 series indicator be used for AC?

DC stands for Direct Current, which can be used for AC

13. Can the AD16 series indicator be customized to IP67?

No.

14. Can the AD16-22 series indicator be used for Φ25 perforated panels?

Yes, no accessories are required. If the customer wants to fit the hole more perfectly, you can also add a Φ25 reducer ring.

15. Which products in the AD16 series indicators are UL listed?

Currently, only the AD16-25 (R25T) lamp has UL certification

16. What is the reason why the indicator voltage is disconnected, but the light is shining?

The LED chip has low energy consumption, low glow voltage, and the indicator light will be on when there is an induced voltage in the field. To avoid this, anti-interference products can be used.

17. Can the AD16 series indicator beads be replaced?

No.

18. What are the types of AD16 series indicators?

According to the opening size, there are three types: 22.5mm AD16-22 series, 16mm AD16-16 series, 12mm AD16-12A series

19. Can the AD16 AC indicator be used for DC? What will be the impact?

The AC indicator cannot be used for DC and will burn out the indicator. Under normal circumstances, the moment the DC power is turned on, it will be very bright, and it will be dimmed instantly, because the internal capacitance is broken down, but it may be that the LED has not been burned out, so it can maintain a little residual brightness.

20. What is the maximum and minimum voltage of the AD16-22 series indicators?

The minimum AC/DC5V, the maximum AC/DC500V
Siemens APT - AD16 series indicator frequently asked questions

More on that
Siemens APT Relays – Testing of Relays Siemens APT Relays – Testing of Relays

(1) Measure the resistance of the contact: use the resistance of the multimeter to measure the resistance of the normally closed contact and the moving point, and the resistance value should be 0; The resistance between the normally open contact and the moving point is infinite. From this, it is possible to distinguish which is a normally closed contact and which is normally open. (2) Coil resistance: multimeter R...

Introduction to the characteristics of Siemens APT relays - solid state relays Introduction to the characteristics of Siemens APT relays - solid state relays

Solid state relay is a non-contact electronic switch with isolation function, no mechanical contact parts in the switching process, so in addition to having the same function as electromagnetic relay, solid state relay also has logic circuit compatibility, vibration resistance and mechanical impact resistance, unlimited installation position, and good anti-...

Siemens APT current transformer - classification of current transformer and its function Siemens APT current transformer - classification of current transformer and its function

1. Current transformers are classified according to the installation method According to the installation method, the current transformer can be divided into through-type current transformer, pillar type current transformer, bushing type current transformer, and busbar type current transformer. Through-type current transformer: used to pass through the screen or wall...

Siemens APT limit switches – the difference between proximity switches and travel switches Siemens APT limit switches – the difference between proximity switches and travel switches

01 The role is different Proximity switches are contactless switches with a long life and are suitable for "pass-through signals". The travel switch is also known as the limit switch, the travel switch and the limit switch are both position switches, but the travel switch can detect the stroke, and can be used as an input signal to control the circuit at a certain distance ...

Siemens APT Relays – Common Causes of Failure of Solid State Relays Siemens APT Relays – Common Causes of Failure of Solid State Relays

1. The reason for the frequent disconnection of the coil: whether the solid state relay is cleaned with ultrasonic, whether the coil is overvoltaged, etc., will cause the coil to be disconnected. 2. The reason for the insufficient power supply of the coil: First, it is necessary to confirm the voltage of the solid state relay coil. If the voltage supplied to the coil is lower than ...

Siemens APT current transformer – current transformer operating error Siemens APT current transformer – current transformer operating error

When the current transformer is finalized and its internal parameters are determined, the magnitude of the error will be affected by the secondary current (or primary current), secondary load, power factor, and frequency. These factors are called external factors, and the error of the current transformer in operation is mainly affected by these four factors. ...

Siemens APT Relays – the solution to common faults in solid state relays Siemens APT Relays – the solution to common faults in solid state relays

1. The simplest and most effective way is to use a new solid state relay. 2. The other is to determine the voltage of the coil to avoid the voltage provided by the coil being less than the operating voltage. 3. Check whether the polarity is reversed. 4. Reasonable power-on time for the solid state relay coil, if ...

Siemens APT Relays – What are the forms of protection relays? Siemens APT Relays – What are the forms of protection relays?

Rail protection relays A protective relay that works mainly as a result of accidents that occur in transmission lines. When this method works, the circuit breakers at both ends of the faulty line will be disconnected. Busbar protection relays A protective relay, mainly due to the power plant or transformer...

Siemens APT Relays - Installation Precautions for High and Low Voltage Relays Siemens APT Relays - Installation Precautions for High and Low Voltage Relays

1. Choose the right relay: When choosing a high and low voltage relay, you should choose the right product according to your needs, such as selecting according to the rated voltage, current and other information 2. Installation location: high and low voltage relays should be installed in dry, ventilated, non-corrosive gas, less dusty areas, ...

Siemens APT - ALH-0.66 series transformer FAQ Siemens APT - ALH-0.66 series transformer FAQ

1. What is the maximum voltage that can be used for an ALH transformer? AC low voltage up to 720V 2. Is there a protective grade product for ALH transformers? II-P AND III-P are available in both protective grades 3. What is the maximum primary current of ALH transformer? The maximum primary side current is 8 ...

Siemens APT Relays – Reliability of Relays Siemens APT Relays – Reliability of Relays

1. The influence of the environment on the reliability of the relay: the average time between failures of the relay is the highest under GB and SF, reaching 820,000h, while in the NU environment, it is only 60,000h. 2. The influence of quality grade on the reliability of relays: when the relay of A1 quality grade is selected, the flat ...

Siemens APT current transformer - inspection content of current transformer Siemens APT current transformer - inspection content of current transformer

1. Regularly check whether the current transformer is overheated, check whether there is discoloration in the terminal, and check whether there are sundries in the terminal box. 2. Check whether there is oil leakage in the oil level gauge in time to ensure that the oil level meets the use standard and there is no oil leakage.

Siemens APT Relays - Maintenance Methods for Solid State Relays Siemens APT Relays - Maintenance Methods for Solid State Relays

1. The influence of the ambient temperature The load capacity of the solid state relay is greatly affected by the ambient temperature and its own temperature rise, during the use of the device, it should be ensured that it has good heat dissipation conditions, the rated working current of more than 10A products should be equipped with radiators, and the products above 100A should be dissipated.

Siemens APT Relays - Maintenance Methods for Solid State Relays Siemens APT Relays - Maintenance Methods for Solid State Relays

1. The influence of the ambient temperature The load capacity of the solid state relay is greatly affected by the ambient temperature and its own temperature rise, during the use of the device, it should be ensured that it has good heat dissipation conditions, the rated working current of more than 10A products should be equipped with radiators, and the products above 100A should be dissipated.

Siemens APT Relays - Selection Method for Solid State Relays Siemens APT Relays - Selection Method for Solid State Relays

1. When selecting the solid-state relay used in the printed circuit board with small current specifications, because the lead terminal is made of high thermal conductivity material, the soldering should be carried out under the condition that the temperature is less than 250 °C and the time is less than 10S.

Siemens APT new x. The new product of R series relay was released Siemens APT new x. The new product of R series relay was released

On May 8, 2019, APT held a grand online conference in Shanghai, Beijing, Guangzhou, Nanjing, Changsha and Tiantai...... and more than 20 cities across the country witnessed the new Siemens APT x. The new product of R series relay was released. ...

Siemens APT Relays – The difference between AC relays and DC relays Siemens APT Relays – The difference between AC relays and DC relays

1. Structural characteristics of AC relays The coil of the AC relay is shorter, and the wire diameter is thicker, mainly because the coil is passed through the alternating current, the reactance is larger, and the thick wire diameter can reduce the internal resistance and reduce the heat generation.

Siemens APT Relays - Precautions for the use of solid state relays Siemens APT Relays - Precautions for the use of solid state relays

1. When choosing the solid state used in the printed circuit board with small current specifications, because the lead terminal is made of high thermal conductivity material, the welding should be carried out under the condition that the temperature is less than 250 °C and the time is less than 10S.

Siemens APT Relays – What are the types of protection relays? Siemens APT Relays – What are the types of protection relays?

Overcurrent Relay (OCR) It operates when a certain value or greater of current flows through. There are two elements: overcurrent detection (known as a timing element) and short-circuit current detection (as an instantaneous element). Earth Fault Overcurrent Relays (OCGR, GR) While...

Siemens APT relay - the main structural features of high and low voltage relays Siemens APT relay - the main structural features of high and low voltage relays

1. Electromagnet: The electromagnet of high and low voltage relay is usually composed of two parts: coil and core. When the high and low voltage relay inputs the electrical signal, the electromagnet coil will generate electromagnetic force, drive the iron core, and realize the on/off control of the relay. 2. Contact group: The contact group is a high and low voltage relay control ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top