RKC thermostat REX-C400 model settings and parameter instructions

Create Date: 2024-8-30 12:03:23|Source: RKC

Japan RIKA RKC REX-C400 temperature controller product introduction

REX-C400 Digital Thermostat RKC PID Temperature Controller Thermostat (SSR Output) + Type K Thermocouple + *Large 40A SSR Relay

1. Dual display set temperature and process temperature

2. Universal digital programmable temperature controller, support a variety of thermocouple sensors. It can be powered by 85-265V AC, Comsumption 5VA. DIN 1/16。

3. Display the temperature in degrees Celsius

4.Four digital LED display can reach "9999"

5.P Powered by DC or AC power supply

6. Used for temperature control of kiln, hearth, oven, incubator

7. Used for heating control and cooling control

8. Used in various industries to control and monitor process temperature

Japan RIKA rkc REX-C400 thermostat technical data sheet:

REX-C400 (SSR) temperature controller

Display: Celsius Dual Display (C)

Range: -0-400C (for factory type K thermocouples only)

Output: SSR

PID cooling/heating control

1 RELAY Alarm: Normally open, capacity 250V/3A AC or 30V/3A DC

7 different dual output combinations with: High/Low/High Deviation/Low Deviation/Interval/Out of Interval/Breakage Alarm

Accuracy: 0.5%

Input: RTD: PT100, Cu50

Thermocouples: J, S, K, E, Wre3 – Wre25

Size: DIN: 1/8 (48mm x 96mm x 110mm)

Weight: about 300 grams

Type K thermocouple probe cable

  1.Length:1M

2. Sensor diameter: 5mm

3. Temperature range: 0-400

4. Internal insulation: fiberglass

5. External shielding: insulation shielding

* Large 40A SSR

1. Output current: 40A

2. Input voltage: DC 3-32V

3. Output voltage: 24-380V AC

4. Output voltage range: standard type

Package includes:

SET 1: REX C400 SSR SETTINGS

1 x PID temperature controller

1 x XK probe sensor

  1 X Max.40A SSR

  SET 1: REX C400 SSR单

1 x PID temperature controller
RKC thermostat REX-C400 model settings and parameter instructions

More on that
RLC Thermostat – How to use a smart temperature controller RLC Thermostat – How to use a smart temperature controller

1. Set temperature: press and hold the SET key, at this time the tube character begins to flash, proving that the instrument has entered the set state, increase the up button, decrease the down button, and press and hold the up and down buttons to quickly change, when the desired temperature is reached, then press the SET button The instrument is set. 2. Return control: press SET ...

RKC Level Gauge – Buoy Level Gauge Use and Precautions RKC Level Gauge – Buoy Level Gauge Use and Precautions

1. Support welding under the guidewire: According to the direction of the movement of the buoy of the level gauge, determine the position at the bottom of the container, and fix the guide bracket (piece 1) under the welded or riveted steel wire 2. Install the guide rail joint. (1) Straighten the wire forcefully and fix it at the lower support, taking care not to ...

RKC Level Gauge – How to properly use a plug-in float level gauge for level measurement RKC Level Gauge – How to properly use a plug-in float level gauge for level measurement

1. Select the appropriate level gauge First of all, it is necessary to choose the appropriate level gauge. The following factors should be taken into account in the selection of a level gauge: Measure the properties of the medium: e.g., temperature, pressure, viscosity, corrosiveness, etc. Measuring range: i.e. the height range of the liquid ...

RKC level gauge - the fault and treatment method of float level gauge RKC level gauge - the fault and treatment method of float level gauge

Fault 1, the indication is abnormal The float level gauge is not indicated properly and is a very common fault of the float level gauge. Usually there are the following manifestations: Phenomenon 1: The float level gauge in the atmospheric pressure workshop has the largest indication. Troubleshooting: The float was found to be ...

A few things to note about the installation of the RKC thermostat A few things to note about the installation of the RKC thermostat

1) For RTD input, 3 wires with low resistance and no difference should be used. 2) The input signal line should be far away from the power line of the instrument, the power supply line and the load line to avoid noise and annoyance. 3) The power cord of the instrument is generally annoyed by the power supply. 4) Instrument complement ...

RLC Thermostat - Introduction to the function of mechanical temperature control RLC Thermostat - Introduction to the function of mechanical temperature control

1. The temperature setting is set by the knob, which is convenient and intuitive 2. It can be directly installed on the standard junction box on the wall. 3. Beautiful appearance and reliable performance. 4. The switch adopts toggle type, which feels comfortable and has a long life. 5. It can control two-wire or three-wire electric (ball...

Overview of the RLC thermostat Overview of the RLC thermostat

CH and CD series intelligent temperature controller is a multi-functional adjustment instrument with special microprocessing, which adopts switching power supply and surface mount technology (SMT), so the instrument is delicate and compact, and the performance is reliable. The unique self-diagnosis function, self-tuning function and intelligent control function make it possible for the operator to pass the ...

RLC Thermostat - Fault and Troubleshooting of Vapor Pressure Temperature Controller RLC Thermostat - Fault and Troubleshooting of Vapor Pressure Temperature Controller

Faulting and troubleshooting of vapor pressure temperature controllers (1) Common faults and common faults of the vapor pressure type temperature controller include contact burning or adhesion, failure of the mechanical transmission mechanism and leakage of temperature sensor in the temperature sensing tube. Its detection method is: put the thermostat knob in a parking position, and use ...

RKC thermostat - introduction of three wiring methods of thermal resistance RKC thermostat - introduction of three wiring methods of thermal resistance

1. The three wiring methods of Pt100 RTD are different in principle: The two-wire system and the three-wire system are measured by the bridge method, and the relationship between the temperature value and the analog output value is given after ***. There is no bridge on the four wires, it is completely just sent with a constant current source, measured by a voltmeter, and the test is given after *** ...

Analysis of common fault causes of RKC temperature controller Analysis of common fault causes of RKC temperature controller

1. The power indication is normal, but the temperature controller has no screen display. Most of this fault is caused by the heating of the voltage regulator element (7805 or 7812) on the thermostat during long-term use, which causes the solder joint to show a breakpoint, and sometimes it is caused by the phenomenon of virtual soldering at the factory. 2. Temperature controller ...

RKC Thermostat – Teach you how to choose a thermostat RKC Thermostat – Teach you how to choose a thermostat

(1) Size selection When replacing the thermostat, choose according to the original size; The newly added thermostat should take into account the overall coordination of the cabinet installed, too large to fit, too small to see the display, the same function of the thermostat, the price of large volume will be more expensive, small size may function expansion...

RKC Level Gauge – Four mounting methods for buoy level gauges RKC Level Gauge – Four mounting methods for buoy level gauges

1. The buoy level gauge is welded and installed under the guide wire At the bottom of the container, determine the position according to the requirements of the movement direction of the level gauge buoy, and weld or rivet the support under the fixed guide wire. 2. Buoy level gauge ruler installation 1. The connecting part of the ruler should be flat.

Technical characteristics of the RKC thermostat Technical characteristics of the RKC thermostat

The core control algorithm of the thermostat is PID control, P (Proportional) + I (Integral) integral + D (Differential) differential control. In addition to the traditional PID control algorithm, RKC also has ON-OFF control, self-tuning parameter control, adaptive parameter control and other algorithms, temperature control ...

RKC thermostat - how to keep the line when installing the thermostat? RKC thermostat - how to keep the line when installing the thermostat?

First, the selection of the orientation of the thermostat device 1. Easy to operate locally; 2. It can include the average temperature of the local area; 3. Localities with more human activities; 4. It can avoid cold and heat sources; That is to say, the orientation of the device should be far away from radiators, away from doors and windows...

RK thermostat - classification and precautions for use of central air conditioning thermostat RK thermostat - classification and precautions for use of central air conditioning thermostat

1. The principle of central air conditioning thermostat Mechanical thermostats can be divided into vapor pressure thermostats, liquid expansion thermostats, gas adsorption thermostats and metal expansion thermostats. Among them, the vapor pressure thermostat is divided into inflatable type, liquid-gas mixed type and liquid-filled type. Domestic...

RRKC Thermostat – The solution to the failure of the jump thermostat switch RRKC Thermostat – The solution to the failure of the jump thermostat switch

1. The cleanliness and finish of the contact surface have a great impact on the working state of the contact. When the appearance of the contact is rough or there is residue on the contact, it is easy to cause arcing and reduce the life of the contact. Therefore, the parts cleaning process should be improved to eliminate the residues; Add the process of residue selection, ...

RKC converter - an introduction to the classification of converters RKC converter - an introduction to the classification of converters

  Analog-to-digital converters The analog-to-digital converter comprises a first transmission circuit, which receives an input voltage and an output clock signal, which is phase-shifted, depending on the input voltage, and a second transmission circuit receives a reference voltage and an input clock signal, and outputs a reference clock signal, which ...

RRKC thermostat - how to set the parameters of the temperature control meter RRKC thermostat - how to set the parameters of the temperature control meter

1. Sensor type (this is based on the actual sensor used) 2. Upper and lower limit range (usually marked on the sensor) 3. Output range setting (current or voltage signal output) 4. Alarm value setting 5. Communication parameter setting (if no point 3 is set, ...)

RKC Level Gauge – How the level gauge works RKC Level Gauge – How the level gauge works

Measuring principle with hydrostatic pressure: When the level transmitter is placed at a certain depth in the liquid to be measured, the pressure on the welcome surface of the sensor is formulated as: Ρ = ρ .g.H + Po where: P: The pressure on the fluid surface of the transmitter ρ: the density of the liquid to be measured g ...

RKC converters – what are the functions of converters? RKC converters – what are the functions of converters?

1. Power conversion: convert the voltage (rated 100V) and current (rated 5A or 1A) of the transformer into voltage (several volts) to meet the requirements of weak current components. 2. Isolation: current, secondary side security, and work grounding are used to ensure the safety of people and equipment, while weak current ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top