RRC thermostat - the principle of sudden jump thermostat, how to judge the good or bad?

Create Date: 2024-8-30 12:03:23|Source: RKC

1. What is the principle of the sudden jump thermostat?

The sudden jump thermostat is a kind of thermostat, which is a series of automatic control elements that are physically deformed inside the switch according to the temperature change of the working environment, resulting in some special effects and on-off action. The sudden jump thermostat is a kind of bimetal disc after constant temperature as a heat-sensitive reaction component, when the temperature of the main part of the product increases or decreases, the heat generated is transferred to the bimetal disc, and when the action temperature is set, it acts quickly, and the contact is disconnected or closed through the action of the mechanism, so as to achieve the purpose of turning on or disconnecting the circuit, so as to control the circuit.

2. How to judge the quality of the sudden jump thermostat

1. Temperature sensing speed. The temperature sensing speed of the sudden jump thermostat needs to match the power of the heating product, the greater the power and the faster the heating, then it is necessary to think about the temperature sensing time of the thermostat and accurately select the temperature section, and the thermostat needs to have the characteristics of fast temperature sensing, fast action, and no arcing.

2. The heating of the thermostat itself, the copper data inside the current thermostat, the heating of different copper materials is not the same, if the heat of the data used is large, it will affect the temperature sensitivity of the bimetal sheet. In this way, it is necessary to choose a thermostat with no current thermal effect planning, accurate temperature and long life.

3. The device of the thermostat. The temperature sensing of the temperature control switch is based on the aluminum cover sealed on the surface and then added to the internal air of the thermostat, or the heat is radiated to the temperature sensing body through the aluminum cover, so the device should make the product close to the device surface of the controlled appliance. Then it is also necessary to think about the device, not to vigorously collapse or deform the shell, so as not to affect its function.

3. Precautions for the installation of sudden jump thermostats

1. When the contact temperature sensing installation is adopted, the metal upper cover plane of the temperature switch should be completely close to the installation surface of the controlled tool. In order to ensure the temperature sensing effect, apply thermal paste to the temperature sensing surface of the appliance.

2. Do not crush, loosen or deform the top of the metal surface of the temperature switch during installation, so as not to affect the function and precision. Do not allow liquids to penetrate the inside of the temperature switch or cause cracks in the housing due to excessive force.

3. Do not change the shape of the external terminal at will, so as not to affect the electrical reliability, and there are insulation protection measures to prevent leakage and ensure the safety of use.
RRC thermostat - the principle of sudden jump thermostat, how to judge the good or bad?

More on that
RKG thermostat – how the temperature controller sets the parameters RKG thermostat – how the temperature controller sets the parameters

1. Lower limit deviation alarm setting: press the SET key to select and display "SLP", the green display screen displays the value of the parameter, and select the shift, increment, and decrement keys to set or modify the parameter. This parameter indicates the difference between the alarm point and the master setpoint. 2. The upper limit deviation alarm is set ...

RHK thermostat – a rapid detection method for common air conditioner thermostats RHK thermostat – a rapid detection method for common air conditioner thermostats

1. Bellows or diaphragm air conditioner thermostat 1. Fault phenomenon: poor contact or burning, resulting in the circuit can not be connected; The frequent action of the contact arc and sticking causes the circuit to be unbreakable; The thermostat in the temperature sensing chamber leaks, causing the contact to fail to operate and lose control. ...

Parameter setting operation of RLC temperature control table CH402 Parameter setting operation of RLC temperature control table CH402

Model: CH402FS01-8*HN (for PECVD temperature control) 1) Single press SET: SV can be set (set temperature manually) 2) Press and hold the SET button for 2 seconds, ALI=1000 (absolute alarm temperature setting) and then press the SET button, ATU=1 (self-defining, self-interpreting a set of PID parameters) to exit ...

RKC Level Gauge – Some installation requirements for pontoon level gauges RKC Level Gauge – Some installation requirements for pontoon level gauges

1. The installation of the level gauge must be vertical to ensure that the inner pontoon can move up and down freely in the pipe body. 2. Install a shut-off valve between the container and the liquid level gauge to clean and overhaul the liquid level timing to cut off the material. 3. No magnets are allowed to approach around the main body of the pontoon level gauge, otherwise ...

RLC thermostat – the working principle of an electronic temperature controller RLC thermostat – the working principle of an electronic temperature controller

Electronic temperature controller, as the name suggests, is a kind of controller that controls the temperature through electronic circuits, it is mainly used for temperature control of electric heating and plumbing, it is easy to learn in the operation method, and the accuracy of control is also very accurate.

RKC converters – what are the functions of converters? RKC converters – what are the functions of converters?

1. Power conversion: convert the voltage (rated 100V) and current (rated 5A or 1A) of the transformer into voltage (several volts) to meet the requirements of weak current components. 2. Isolation: current, secondary side security, and work grounding are used to ensure the safety of people and equipment, while weak current ...

Introduction and wiring method of Japan physical and chemical RKC thermostat Introduction and wiring method of Japan physical and chemical RKC thermostat

  The core control algorithm of the temperature regulator is PID control, P (Proportional) ratio + I (Integral) point + D (Differential) differential control. In addition to the traditional PID control algorithm, RKC also has ON-OFF control, custom parameter control, adaptive parameter control and other algorithms, ...

RRKC Thermostat – Questions and Precautions About Thermostat Expansion Modules RRKC Thermostat – Questions and Precautions About Thermostat Expansion Modules

1. Under what circumstances should I use a thermostat to expand the module? The gradual development of the heating field is now very well recognized, and more and more users have begun to install electric heating, of course, when installing electric heating for users, they have also encountered some headaches. For example, a large area ...

RKG thermostat - an introduction to the relevant knowledge of temperature controllers RKG thermostat - an introduction to the relevant knowledge of temperature controllers

The temperature controller is an electrical switchgear that controls the temperature of an air-conditioned room. The temperature range in the air-conditioned room controlled by the temperature controller is generally 18°C--28°C. The temperature controller commonly used in window air conditioners uses the principle of pressure to push the contacts on and off. Its structure consists of bellows ...

RKC Level Gauge – The correct maintenance method for float level gauges RKC Level Gauge – The correct maintenance method for float level gauges

(1) After 6 months to 1 year of operation, the sensor should be visually inspected and routinely calibrated. (2) Regularly check whether the sensor is bent and deformed by external force to avoid ball jamming. (3) Regularly check whether the magnetic induction switch element of the sensor is aging and failing, ...

How to set the parameters of RKC thermostat RH900 How to set the parameters of RKC thermostat RH900

1. Lower limit deviation alarm setting: press the SET key to select and display "SLP", the green display screen displays the value of the parameter, and select the shift, increment, and decrement keys to set or modify the parameter. This parameter indicates the difference between the alarm point and the master setpoint. 2. The upper limit deviation alarm is set ...

A few things to note about the installation of the RKC thermostat A few things to note about the installation of the RKC thermostat

1) For RTD input, 3 wires with low resistance and no difference should be used. 2) The input signal line should be far away from the power line of the instrument, the power supply line and the load line to avoid noise and annoyance. 3) The power cord of the instrument is generally annoyed by the power supply. 4) Instrument complement ...

What should I pay attention to when wiring the RKG thermostat? What should I pay attention to when wiring the RKG thermostat?

1. For thermocouple input, the corresponding compensation wire should be used. 2. For RTD input, 3 wires with low resistance and no difference should be used 3. The input signal line should be far away from the power line of the instrument. Power supply and load lines to avoid noise interference 4. The instrument power cord is usually ...

RRKC Thermostat – The working principle and main features of the pop-up thermostat RRKC Thermostat – The working principle and main features of the pop-up thermostat

How it works The sudden jump thermostat is a kind of bimetal disc after constant temperature as a heat-sensitive reaction component, when the temperature of the main part of the product increases or decreases, the heat generated is transferred to the bimetal disc, and when the operating temperature is set, it acts quickly, and the contact is broken through the action of the mechanism.

Specifications and models of RLC thermostats Specifications and models of RLC thermostats

CH102 (48×48×100mm) CH402 (48×96×100mm) CH902 (96×96×100mm) 1. RH400 size: 48*96, depth 60, about 250g 1. Thermocouples: K, J, R, S, B, E, N, T, W5RE/W6RE, PL‖, U, L ...

RLC thermostat – the wiring method of the thermostat RLC thermostat – the wiring method of the thermostat

Many household appliances and large-scale equipment products will be installed in the use of thermostats, thermostats will be combined with the change of ambient temperature in the switch when working physical deformation, which will produce some special effects, resulting in conduction or disconnection action, in order to achieve automatic ...

RLC Thermostat – How to use a smart temperature controller RLC Thermostat – How to use a smart temperature controller

1. Set temperature: press and hold the SET key, at this time the tube character begins to flash, proving that the instrument has entered the set state, increase the up button, decrease the down button, and press and hold the up and down buttons to quickly change, when the desired temperature is reached, then press the SET button The instrument is set. 2. Return control: press SET ...

RRKC thermostat - common faults and solutions of stand-alone thermostats RRKC thermostat - common faults and solutions of stand-alone thermostats

Fault 1: The thermostat does not turn on (does not light up) Analyze the causes 1. Wrong wiring 2. The voltage of the input terminal is not enough or the input terminal is damaged by empty opening and leakage 3. Whether the cable between the panel and the power board is broken or plugged incorrectly 4. Load short circuit or open circuit, probe ...

How to set the parameters of the RKC rs400 thermostat? How to set the parameters of the RKC rs400 thermostat?

1. Set temperature: Press the SET button to set or check the temperature set point. Press the SET key digital tube character start flashing, indicating that the appearance has entered the setting state, press the △ key to increase the set value, press the ▽ key to decrease the set value, press and hold the △ key or ▽ key data will change rapidly, press the SET key again ...

What problems are easy to encounter in the use of RKCPT100 temperature sensor probes? What problems are easy to encounter in the use of RKCPT100 temperature sensor probes?

What problems are easy to encounter in the use of PT100 temperature sensor probes? 1. Is the output signal unstable? A: Maybe it's the temperature instability of the temperature source itself, or the problem of on-site disturbance. 2. Is there a big error in the output of the transmitter? Answer: This ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top