1. The use environment of the sudden jump thermostat should avoid stains and moisture, otherwise it will affect the electrical performance of the product, and the thermostat must be used in a working environment with a relative humidity of ≤ 90% and no contact with corrosive and flammable mediums. For use in wet environments or submerged liquids, a special impermeable seal is required for the thermostat.

2. When the sudden jump thermostat is installed, it is absolutely not allowed to deform the temperature sensing surface (cover), and the top of the cover should not be collapsed or deformed, so as not to affect the temperature and electrical performance of the thermostat;

3. When the sudden jump thermostat is installed, the temperature sensing surface of the thermostat cover should be evenly touched with the temperature control part; When the thermostat adopts contact temperature sensing, it is best to coat a layer of thermal conductive grease on the temperature-sensing surface of the cover, so that there is no gap between the temperature-sensing surface and the temperature-controlled surface, so as to improve the thermal conductivity effect.

4. When the sudden jump thermostat is installed, the terminal of the thermostat should not be bent, and the wiring of the terminal should be in good contact, otherwise the reliability of the electrical contact will be affected. If solder wiring is used, a soldering iron of no more than 60W should be selected, and the soldering time should be controlled within 5 seconds.

5. When selecting the sudden jump thermostat, the temperature selection should be accurate. Due to the influence of various factors such as thermal inertia, conduction, etc., so as to avoid changes in temperature.
What should be paid attention to when installing RRKC thermostats - pop-up thermostats

More on that
RKC Level Gauge – Buoy Level Gauge Use and Precautions RKC Level Gauge – Buoy Level Gauge Use and Precautions

1. Support welding under the guidewire: According to the direction of the movement of the buoy of the level gauge, determine the position at the bottom of the container, and fix the guide bracket (piece 1) under the welded or riveted steel wire 2. Install the guide rail joint. (1) Straighten the wire forcefully and fix it at the lower support, taking care not to ...

How to set the parameters of RKC thermostat CD901? How to set the parameters of RKC thermostat CD901?

1. Lower limit deviation alarm setting: press the SET key to select and display "SLP", the green display screen displays the value of the parameter, and select the shift, increment, and decrement keys to set or modify the parameter. This parameter indicates the difference between the alarm point and the master setpoint. 2. The upper limit deviation alarm is set ...

For some considerations in the RKG thermostat setup For some considerations in the RKG thermostat setup

RKC Thermostat Operation Note: 1. Clean the instrument only after the power is off; 2. To remove the stains on the monitor, please use a soft cloth or cotton paper; 3. The display is easy to be scratched, and it is forbidden to use hard objects to operate the panel buttons, otherwise the buttons will be damaged or scratched. RLC thermostat ...

RKC Level Gauge – the correct way to use the float level gauge RKC Level Gauge – the correct way to use the float level gauge

(1) Before use, first check whether the level gauge is within the verification cycle, otherwise, it should be calibrated, and replaced in time if it is unqualified. (2) The sensor should be installed horizontally, and the length of the lower entry should meet the technical requirements. (3) The connection between the sensor and the explosion-proof junction box should be tightened and tightened.

RKC converters – what are the functions of converters? RKC converters – what are the functions of converters?

1. Power conversion: convert the voltage (rated 100V) and current (rated 5A or 1A) of the transformer into voltage (several volts) to meet the requirements of weak current components. 2. Isolation: current, secondary side security, and work grounding are used to ensure the safety of people and equipment, while weak current ...

RRKC thermostat – the main function of the thermostat RRKC thermostat – the main function of the thermostat

In most cases, in Europe, the thermostat is a necessary accessory for the wall-hung boiler, and the two are delivered to the user at the same time, and most of the thermostats equipped are intelligent thermostats. In China, nearly 95% of the wall-hung boilers that have been installed in operation and are being installed and debugged and ready to be put into use are not equipped in advance.

Overview of the RLC thermostat Overview of the RLC thermostat

CH and CD series intelligent temperature controller is a multi-functional adjustment instrument with special microprocessing, which adopts switching power supply and surface mount technology (SMT), so the instrument is delicate and compact, and the performance is reliable. The unique self-diagnosis function, self-tuning function and intelligent control function make it possible for the operator to pass the ...

RKC Level Gauge – The structure of a float level gauge RKC Level Gauge – The structure of a float level gauge

(1) For the indicator, also known as the display panel, the indicator plays the role of local display, convenient for long-distance observation of the actual situation of the liquid level, the indicator is generally bundled with the pontoon, easy to install. (2) It is a magnetic float, which is located in the pontoon and is in direct contact with the liquid to be measured, ...

RKG thermostat – how the temperature controller sets the parameters RKG thermostat – how the temperature controller sets the parameters

1. Lower limit deviation alarm setting: press the SET key to select and display "SLP", the green display screen displays the value of the parameter, and select the shift, increment, and decrement keys to set or modify the parameter. This parameter indicates the difference between the alarm point and the master setpoint. 2. The upper limit deviation alarm is set ...

RKC Thermostats – How to Choose a Thermocouple? RKC Thermostats – How to Choose a Thermocouple?

The selection of thermocouples should be based on comprehensive considerations such as the operating temperature range, the required accuracy, the operating atmosphere, the performance of the measured object, the response time and the economic benefits. 1. Selection of measurement accuracy and temperature measurement range 1) The operating temperature is 1300-1800°C, and the accuracy is required to be more accurate than ...

Wiring method of the RKG thermostat Wiring method of the RKG thermostat

Take CD901 as an example, L(1) pin to 220 volt live wire, N(2) pin 220 volt neutral wire, 3,4 pins for *** output, 5,6 pins for the second output, 7, 8, 9 pins are alarm output, The rear three pins are connected to thermocouples or PT100 and so on.

RKC converter – the design essentials of the power converter RKC converter – the design essentials of the power converter

In the design of power converter, firstly, the circuit topology is determined according to the load requirements, and the composition and backup mode of the power converter are determined, and the main parameters of the power converter are input voltage range, output voltage accuracy, load stability, voltage stability, output ripple, efficiency and dynamic.

RKC Temperature Control Meter - How to set the temperature control meter RKC Temperature Control Meter - How to set the temperature control meter

1. Turn on the power supply of the smart thermostat, and the temperature displayed on the screen is the temperature at that time. Because the sensor is not in contact with other devices, but is directly exposed to the air clock, this is the current temperature: 31 degrees Celsius, which is not too hot. 2. At the bottom right of the display screen is the "starting temperature" setting ...

Introduction to the functions of the RKC temperature control meter Introduction to the functions of the RKC temperature control meter

(1) RH400 size: 48*96, depth 60, about 250g Details: ●A variety of input types are available: 1) Thermocouples: K, J, R, S, B, E, N, T, W5RE/W6RE, PL‖, U, L 2) Temperature measurement RTD input: PT100, JPT100...

Introduction to the types of alarms for RRKC thermostats Introduction to the types of alarms for RRKC thermostats

* Alarm table {ALM1} (standard built-in) A: Upper limit deviation alarm G: Standby upper and lower limit deviation alarm attached B: Lower limit deviation alarm H: Upper limit input value alarm C: Upper and lower limit deviation alarm J: Lower limit input value alarm D: Alarm in the range K: Attached standby ...

RRKC Thermostat – The solution to the failure of the jump thermostat switch RRKC Thermostat – The solution to the failure of the jump thermostat switch

1. The cleanliness and finish of the contact surface have a great impact on the working state of the contact. When the appearance of the contact is rough or there is residue on the contact, it is easy to cause arcing and reduce the life of the contact. Therefore, the parts cleaning process should be improved to eliminate the residues; Add the process of residue selection, ...

RRC Thermostat – Instructions for use of smart thermostats RRC Thermostat – Instructions for use of smart thermostats

1. Turn on the power of the smart thermostat, and the current temperature is displayed on the display. Because the sensor is not in contact with other devices, but is exposed directly to the air, this is the current temperature: 31 degrees Celsius, which is not too hot. 2. At the bottom right of the display is the "Startup Temperature" setting.

RLC thermostat – the working principle of an electronic temperature controller RLC thermostat – the working principle of an electronic temperature controller

Electronic temperature controller, as the name suggests, is a kind of controller that controls the temperature through electronic circuits, it is mainly used for temperature control of electric heating and plumbing, it is easy to learn in the operation method, and the accuracy of control is also very accurate.

RK Thermostat - The working principle and device precautions of liquid expansion thermostat RK Thermostat - The working principle and device precautions of liquid expansion thermostat

How liquid expansion thermostats work Liquid expansion thermostat is a physical phenomenon (volume change) that causes the material (generally liquid) in the temperature sensing part of the thermostat to undergo corresponding thermal expansion and cold contraction when the temperature of the controlled object changes, and the diaphragm box connected with the temperature sensing part expands or ...

RKC thermostat - what are the anti-interference measures of the instrument? RKC thermostat - what are the anti-interference measures of the instrument?

1. Electromagnetic induction (refers to the coupling of magnetism). There is a strong alternating magnetic field in the surrounding space of high-power transformers, AC motors, high-current power grids, etc., and the closed loop formed by the lines of the control system (detection, transmission, conversion, regulation, calculation, execution, auxiliary, display, etc.) is located in the ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top