CH102 (48×48×100mm)
CH402 (48×96×100mm)
CH902 (96×96×100mm)
1. RH400 size: 48*96, depth 60, about 250g
1. Thermocouples: K, J, R, S, B, E, N, T, W5RE/W6RE, PL‖, U, L
2. Temperature measurement heat resistance input: PT100, JPT100
3. Tributary voltage: DC0 - DC5V, DC1 - DC5V
Sampling period: 0.5s
Measurement accuracy: Thermocouple: ± (0.3% of displayed value + 1 digit) or ± 2 degrees Temperature measurement resistance: ± (0.3 + 1 digit of displayed value)
(DC0/12V) allowable load resistance above 600 ohms, can be heated and cooled dual output control (output 1: heating side; Output 2: Cooling side)
Optional heater disconnection alarm and control loop disconnection alarm
2. CH402 size: 48*96, depth 100, about 250g
1. Temperature measurement resistance input: PT100, JPT100
2. Tributary voltage: DC0 - DC5V, DC1 - DC5V
3. Tributary current: DC0-20MA, DC4-20MA (250 ohm external resistance required)
Sampling period: 0.5s
Optional heater disconnection alarm and control loop disconnection alarm
Optional 2-wire RS-485 communication
3. CD901 size: 96*96 depth 100, about 340g
1. Temperature measurement resistance input: PT100, JPT100
2. Tributary voltage: DC0 - DC5V, DC1 - DC5V
3. Tributary current: DC0-20MA, DC4-20MA (250 ohm external resistance required)
Multiple alarm types: upper limit input value, lower limit input value, upper limit deviation, lower limit deviation, upper and lower limit deviation, upper and lower range setpoint, lower limit setpoint (standby operation can be attached)
Sampling period: 0.5s
Measurement accuracy: Thermocouple: ± (0.3% of displayed value + 1 digit) or ± 2 degree temperature measurement resistance: ± (0.3% of displayed value + 1 digit) or ± 0.8 degrees tributary voltage/current input: ± (0.3% of displayed value + 1 digit)
(DC0/12V) Allowable load resistance 600, used to drive TRIAC (three-terminal bipolar thyristor) trigger output: Trigger mode - zero cross method, on-current: 50 mA (50 degrees), 70 mA (25 degrees) for zero cross type medium capacity TRIAC (used to drive loads below 100 a) * Heating/cooling type is not possible TRIAC (three-terminal bidirectional thyristor) Output: Rated value 0.5 A (ambient temperature 40 degrees or less)
Optional heater disconnection alarm and control loop disconnection alarm
Optional 2-wire RS-485 communication
4. FB900 size: 96*96*60
Abundant inputs and outputs
Automatic/manual, local/remote direct switching
Multi-area function: Up to 8 different settings can be registered for the master setting, etc., and cumbersome settings can be changed in a lump package. Zones can also be switched via an optional external contact input.
By combining the multi-storage function to connect the number of the other area, the duration of the area, and the setting of the limit of the rate of change, it is possible to run the program up to 16 segments (8 steps).
Frequently used data (up to 16 items) can be freely listed in consecutive addresses, which greatly reduces data transmission and enables high-speed communication.
Joint operation can be carried out using communication
PID control: The sampling cycle can be switched to 0.05s, which corresponds to the high-speed heating process. A new type of heat-and-cool PID that inhibits undershoot on the cooling side. You can switch between the controls of "heating, cooling, heating and cooling, and position ratio".
5. CH102 size: 48*48, depth 100mm about 170g
1. Temperature measurement resistance input: PT100, JPT100
2. Tributary voltage: DC0 - DC5V, DC1 - DC5V
3. Tributary current: DC0-20MA, DC4-20MA (250 ohm external resistance required)
Sampling period: 0.5s
Measurement accuracy: Thermocouple: ± (0.3% of displayed value + 1 digit) or ± 2 degree temperature measurement resistance: ± (0.3% of displayed value + 1 digit) or ± 0.8 tributary voltage/current input: ± (0.3% of displayed value + 1 digit)
Control output: relay contact output: 1c contact (AC250 3A) resistance load voltage pulse output: (DC0/12V) allowable load resistance above 600 ohms current output: (DC4 - 20MA) allowable load resistance above 600 ohms can be heated and cooled dual output control (output 1: heating side; Output 2: Cooling side)
Optional heater disconnection alarm and control loop disconnection alarm
Optional 2-wire RS-485 communication
|
More on that
|
RLC thermostat – what you should pay attention to when maintaining your temperature controller
1. Do not wipe with acidic, alkaline and other corrosive liquids and water-containing rags when cleaning, so as not to damage the temperature controller and affect its normal use.
2. Do not decorate and cover the temperature controller. The thermostat has a built-in temperature sensor to sense the outside temperature. Therefore, Wen ...
|
|
RKC Thermostat – How to Maintain the Instrument?
The normal operation of the instrument is inseparable from the on-site maintenance relationship, especially some important process links, once there is a leak, it will greatly affect the quality of the product, resulting in heavy losses.
First of all, it is common to install both remote and field-indicated level gauges on important tanks.
|
|
RKC Level Gauges - Advantages and Disadvantages of Several Common Level Gauges Introduction
1. Float level gauge is an instrument that relies on the principle of buoyancy to measure the liquid level. Usually by means of a float in conjunction with a scale, the observer can visually read the height of the liquid level.
Advantages: fast and intuitive reading; Low price; Easy to install.
Shortcoming:...
|
|
RHK thermostat – a rapid detection method for common air conditioner thermostats
1
Bellows or diaphragm air conditioner thermostat
Fault Symptom:
Poor contact or burning, resulting in the circuit cannot be connected; The frequent action of the contact arc and sticking causes the circuit to be unbreakable; Leakage of thermostat in the temperature sensing chamber, causing the contacts to fail to operate and lose control ...
|
|
What should I pay attention to when setting up my RKC thermostat?
Wiring Warning:
If the instrument fails or an error occurs, which can cause a system failure, an external protection circuit is installed to prevent such accidents:
In order to prevent damage or failure of the instrument, choose an appropriate fuse to protect the power cord and input and output lines from strong power shocks.
Power supply ...
|
|
RKC Thermostat The structure, action principle and use of some commonly used relays
A relay is an electrical appliance that works automatically. When the amount of electricity such as voltage, current, and frequency or non-electricity such as temperature, pressure, and rotational speed is input to the relay, and when the specified value is reached, the contacts of the relay connect or cut off the circuit that controls or protects it. Relays are widely used in motor control and power ...
|
|
RLC Thermostat – Instructions for installation and use of pop-up thermostats
1. Grounding method: It is connected to the grounding metal parts of the equipment through the metal cover of the thermostat.
2. The thermostat should work in the general indoor environment where the relative humidity of the air is not more than 90%, and there are no corrosive gases, flammable gases and conductive dust.
3. The thermostat adopts contact ...
|
|
Specifications and models of RLC thermostats
CH102 (48×48×100mm)
CH402 (48×96×100mm)
CH902 (96×96×100mm)
1. RH400 size: 48*96, depth 60, about 250g
1. Thermocouples: K, J, R, S, B, E, N, T, W5RE/W6RE, PL‖, U, L
...
|
|
RK thermostat - the selection and installation method and precautions of the central air conditioning thermostat
1. Thermostat output control power: The thermostat output control power is the first issue to consider when choosing a thermostat, which is related to the safety and stability of use, and may cause serious consequences if not selected properly, such as: fire. Thermostat products are marked with output control voltage and current, and the ...
|
|
RKC Level Gauge – How to properly use a plug-in float level gauge for level measurement
1. Select the appropriate level gauge
First of all, it is necessary to choose the appropriate level gauge. The following factors should be taken into account in the selection of a level gauge:
Measure the properties of the medium: e.g., temperature, pressure, viscosity, corrosiveness, etc.
Measuring range: i.e. the height range of the liquid ...
|
|
RKC thermostat operation attention and its main features
RKC thermostat operation attention
· Clean the instrument only after the power is off;
· Please use a soft cloth or cotton paper to remove stains on the monitor;
· The display is easy to be scratched, it is forbidden to use hard object to operate the panel buttons, otherwise the keys will be damaged or scratched.
Key features:
...
|
|
RHK thermostat – a rapid detection method for common air conditioner thermostats
1. Bellows or diaphragm air conditioner thermostat
Fault Symptom:
Poor contact or burning, resulting in the circuit cannot be connected; The frequent action of the contact arc and sticking causes the circuit to be unbreakable; The leakage of the thermostat in the temperature sensing chamber causes the contact to fail to operate and lose control ...
|
|
RKC Thermostats – How to Choose a Thermocouple?
The selection of thermocouples should be based on comprehensive considerations such as the operating temperature range, the required accuracy, the operating atmosphere, the performance of the measured object, the response time and the economic benefits.
1. Selection of measurement accuracy and temperature measurement range
1) The operating temperature is 1300-1800°C, and the accuracy is required to be more accurate than ...
|
|
RK thermostat - classification and precautions for use of central air conditioning thermostat
1. The principle of central air conditioning thermostat
Mechanical thermostats can be divided into vapor pressure thermostats, liquid expansion thermostats, gas adsorption thermostats and metal expansion thermostats. Among them, the vapor pressure thermostat is divided into inflatable type, liquid-gas mixed type and liquid-filled type. Domestic...
|
|
RKC thermostat - what should be paid attention to when maintaining the thermostat?
1. Do not wipe with acidic, alkaline and other corrosive liquids and water-containing rags when cleaning, so as not to damage the temperature controller and affect its normal use.
2. Do not decorate and cover the temperature controller. The thermostat has a built-in temperature sensor to sense the outside temperature. Therefore, Wen ...
|
|
How to set the parameters of RKC thermostat CD901?
1. Lower limit deviation alarm setting: press the SET key to select and display "SLP", the green display screen displays the value of the parameter, and select the shift, increment, and decrement keys to set or modify the parameter. This parameter indicates the difference between the alarm point and the master setpoint.
2. The upper limit deviation alarm is set ...
|
|
What are the rich functions of RRKC thermostats – wall mounted thermostats?
The wall-mounted thermostat is an ultra-thin intelligent thermostat that integrates measurement, display, control, alarm, recording and other functions, which can realize accurate measurement and control of temperature, pressure, flow and other parameters. Available in three sizes of 5 inches, 7 inches and 9 inches, a total of 12 models are available ...
|
|
RRKC thermostat – the correct way to set up the thermostat
Press the SET button to set or view the temperature set point, press the SET key digital tube characters to start flashing, indicating that the instrument has entered the setting state, press the △ key to increase the set value, press the ▽ key to decrease the set value, press and hold the △ key or ▽ key The data will change rapidly, press the SET key again The instrument returns to normal working condition ...
|
|
RKC Level Gauges – An introduction to common types of level gauges
Explosion-proof float level switch
Explosion-proof float level switch, also known as explosion-proof float level controller. It is a liquid level control instrument specially designed and manufactured for use in explosive atmospheres, this product is designed based on the principle of buoyancy and the principle of lever, when the liquid level in the container changes, ...
|
|
RKC Thermostat Common faults of thermostats
The power indicator is normal, but the temperature control meter has no on-screen display. This kind of fault is mostly caused by the heating of the voltage regulator element (7805 or 7812) of the temperature controller during long-term use, resulting in a break point in the solder joint, and sometimes a virtual soldering occurs at the factory, resulting in re-soldering.
...
|
|