|
Overview of the RLC thermostat
CH and CD series intelligent temperature controller is a multi-functional adjustment instrument with special microprocessing, which adopts switching power supply and surface mount technology (SMT), so the instrument is delicate and compact, and the performance is reliable. The unique self-diagnosis function, self-tuning function and intelligent control function make it possible for the operator to pass the ...
|
|
RKC Level Gauges - Advantages and Disadvantages of Several Common Level Gauges Introduction
1. Float level gauge is an instrument that relies on the principle of buoyancy to measure the liquid level. Usually by means of a float in conjunction with a scale, the observer can visually read the height of the liquid level.
Advantages: fast and intuitive reading; Low price; Easy to install.
Shortcoming:...
|
|
RK Thermostat - 5 Common Faults of Thermostat and Solutions
1. After heating for a period of time, it is found that the temperature has not changed, and the temperature has been displayed at the time of the ambient temperature.
In this case, you need to check that the SV value setting value is set, whether the OUT value indicator of the meter is not lit, and whether the No. 3 and 4 segments of the universal meter are 12VD ...
|
|
What are the precautions for the installation of the RKG thermostat?
1) For RTD input, 3 wires with low resistance and no difference should be used.
2) The input signal line should be far away from the power line of the instrument. Power supply and load lines to prevent noise disturbances.
3) The power cord of the instrument is generally disturbed by the power supply.
4) Instrument complement ...
|
|
RKC thermostat - what should be paid attention to when maintaining the thermostat?
1. Do not wipe with acidic, alkaline and other corrosive liquids and water-containing rags when cleaning, so as not to damage the temperature controller and affect its normal use.
2. Do not decorate and cover the temperature controller. The thermostat has a built-in temperature sensor to sense the outside temperature. Therefore, Wen ...
|
|
RKC Level Gauges – Precautions for Level Gauges
The correct selection of the level gauge can ensure the better use of the level gauge. What kind of level gauge should be selected according to the physical and chemical properties of the fluid medium to be measured? What is the diameter of the level gauge, the flow range, the lining material, the electrode material, and the output current? can adapt to the ...
|
|
RRKC thermostat wiring installation and some precautions
The rkc controller was developed by Japan and is mainly used in plastics and stoves. Of course, it is also widely used in China's industry, there are many people who do not know much about the rkc controller, and some even feel unfamiliar.
|
|
The main technical indicators of RKC thermostat
The main technical indicators of RKC thermostat
· Input: various thermocouple (TC), RTD standard current and voltage signals (see input type table);
· basic error: 0.5% of the input full-scale ±±1 word;
· Resolution: 1°C, 0.1°C;
...
|
|
RLC Thermostat – Precautions for Thermostat Operation
1) Measure the function
Its temperature measurement scale is mainly between -20 °C and 80 °C, and the humidity measurement scale is mainly between 20% RH and 99% RH. In addition, it has a temperature resolution of 1°C and a humidity of 1%RH.
2) Parameters and data display functions
Temperature and humidity control ...
|
|
RHK thermostat – a rapid detection method for common air conditioner thermostats
1. Bellows or diaphragm air conditioner thermostat
Fault Symptom:
Poor contact or burning, resulting in the circuit cannot be connected; The frequent action of the contact arc and sticking causes the circuit to be unbreakable; The leakage of the thermostat in the temperature sensing chamber causes the contact to fail to operate and lose control ...
|
|
RLC Thermostat – Instructions for installation and use of pop-up thermostats
1. Grounding method: It is connected to the grounding metal parts of the equipment through the metal cover of the thermostat.
2. The thermostat should work in the general indoor environment where the relative humidity of the air is not more than 90%, and there are no corrosive gases, flammable gases and conductive dust.
3. The thermostat adopts contact ...
|
|
RKC thermostat - what are the anti-interference measures of the instrument?
1. Electromagnetic induction (refers to the coupling of magnetism). There is a strong alternating magnetic field in the surrounding space of high-power transformers, AC motors, high-current power grids, etc., and the closed loop formed by the lines of the control system (detection, transmission, conversion, regulation, calculation, execution, auxiliary, display, etc.) is located in the ...
|
|
RRKC thermostats – how are temperature controllers wired and commissioned?
1. Take out the room temperature controller, and then connect the power supply terminal of the temperature controller to the power supply according to the terminal diagram of the temperature control chart
2. Then take out the temperature sensor that comes with the temperature controller and detect it
3. According to the temperature controller terminal, the temperature sensor is connected to the controller's transmission.
|
|
For some considerations in the RKG thermostat setup
RKC Thermostat Operation Note:
1. Clean the instrument only after the power is off;
2. To remove the stains on the monitor, please use a soft cloth or cotton paper;
3. The display is easy to be scratched, and it is forbidden to use hard objects to operate the panel buttons, otherwise the buttons will be damaged or scratched.
RLC thermostat ...
|
|
RLC thermostats – the classification of thermostats and their detailed introduction
1. Sudden jump thermostat
The type of various sudden thermostats is collectively called KSD, such as KSD301, KSD302, etc., the thermostat is a new type of bimetal thermostat, mainly as a variety of electric heating products with overheat protection, generally connected with the thermal fuse in series, sudden temperature ...
|
|
RLC thermostat – the working principle of an electronic temperature controller
Electronic temperature controller, as the name suggests, is a kind of controller that controls the temperature through electronic circuits, it is mainly used for temperature control of electric heating and plumbing, it is easy to learn in the operation method, and the accuracy of control is also very accurate.
|
|
RKC Level Gauge – Four mounting methods for buoy level gauges
1. The buoy level gauge is welded and installed under the guide wire
At the bottom of the container, determine the position according to the requirements of the movement direction of the level gauge buoy, and weld or rivet the support under the fixed guide wire.
2. Buoy level gauge ruler installation
1. The connecting part of the ruler should be flat.
|
|
The debugging method of the temperature controller
Generally, there are three buttons to provide the need for setting, one is the Set button, press it once to enter the setting state. The other two offer upward and downward temperature adjustments, which can be adjusted to any temperature point. After adjusting to the desired temperature point, press the Set button again to confirm.
1. Turn on the smart thermostat ...
|
|
What should I pay attention to when setting up my RKC thermostat?
Wiring Warning:
If the instrument fails or an error occurs, which can cause a system failure, an external protection circuit is installed to prevent such accidents:
In order to prevent damage or failure of the instrument, choose an appropriate fuse to protect the power cord and input and output lines from strong power shocks.
Power supply ...
|
|
RKC thermostat - introduction of the three output modes of the thermostat
The first output method is relay output, which is output for temperature control through the switching signal of the relay on/off, which is used to directly control the load less than 5A, or directly control the contactor and the intermediate relay, and control the high-power load externally through the contactor.
The second ...
|