Take CD901 as an example,
L(1) pin to 220 volt live wire,
N(2) pin 220 volt neutral wire,
3,4 pins for *** output,
5,6 pins for the second output,
7, 8, 9 pins are alarm output,
The rear three pins are connected to temperature sensor signals such as thermocouples or PT100s
|
More on that
|
Physical and chemical RK C thermostat - dry-type transformer thermostat shows fault handling methods
1. The dry-type transformer thermostat does not appear
Cause of failure: (1) The power supply of the thermostat is not connected; (2) The fuse is blown out.
Solution: (1) Turn on the power supply; (2) Replace the fuse.
2. The dry-type transformer thermostat shows that one or three phases are shining and showing "-OP-"
...
|
|
RKC Thermostat – How can a thermostat be broken?
First, the temperature does not appear
1. Fault with the temperature sensor
If the temperature probe of the temperature sensor breaks or the wire is broken, the sensor does not have a digital display when the temperature sensor is connected, but only shows the "----" and sounds an alarm.
|
|
What are the technical parameters of the rkc thermostat - the jump thermostat?
1. Electrical parameters: (1) VDE, CQC, UL, TüVAC250V 50-60Hz 10A (resistive load) (2) ULAC125V 50Hz 15A (resistive load)
2. Operating temperature range: -50-270°C (optional), temperature accuracy: ≥ ±2°C
3. Reset and action ...
|
|
RKC thermostat How to quickly understand the wiring diagram of the thermostat
There are many models of temperature controllers, and the output methods are slightly different, but the wiring principle is the same.
The working principle of the thermostat: the main circuit of the power supply is directly connected to the heating device through the main contact of the AC contactor.
|
|
RHK thermostat - 5 common problems and solutions for stand-alone thermostats
Fault 1: The thermostat does not turn on (does not light up)
Analyze the causes
1. Wrong wiring
2. The voltage of the input terminal is not enough or the input terminal is damaged by empty opening and leakage
3. Whether the cable between the panel and the power board is broken or plugged incorrectly
4. Load short circuit or open circuit, probe ...
|
|
RKC thermostat – the correct way to adjust the thermostat
1. Set temperature: Press the SET button to set or view the temperature set point. Press the SET key digital tube character start flashing, indicating that the appearance has entered the setting state, press the △ key to increase the set value, press the ▽ key to decrease the set value, press and hold the △ key or ▽ key The data will change rapidly, press the SET key again The appearance will return ...
|
|
Wiring method of the RKG thermostat
Take CD901 as an example,
L(1) pin to 220 volt live wire,
N(2) pin 220 volt neutral wire,
3,4 pins for the first output,
5,6 pins for the second output,
7, 8, 9 pins are alarm output,
Finally, the three pins are connected to thermocouples or PT100 ...
|
|
Common faults and solutions of RKC temperature controllers
1. The power indication is normal, but the temperature controller has no screen display. Most of this fault is caused by the heating of the voltage regulator element (7805 or 7812) on the thermostat during long-term use, which leads to the breakpoint of the solder joint, and sometimes it is caused by the phenomenon of virtual soldering at the factory, and the main re-soldering can be done.
2. Temperature controller ...
|
|
RKC Level Gauges – Precautions for Level Gauges
The correct selection of the level gauge can ensure the better use of the level gauge. What kind of level gauge should be selected according to the physical and chemical properties of the fluid medium to be measured? What is the diameter of the level gauge, the flow range, the lining material, the electrode material, and the output current? can adapt to the ...
|
|
RDC converters – a classification of power converters
Motors are divided into two categories: DC motors and AC motors, and AC motors are divided into asynchronous motors and synchronous motors, and their respective speed regulation principles are also different. According to the speed regulation requirements of the motor, it can be divided into two categories: DC power converter and AC power converter:
...
|
|
RKC Temperature Control Meter - How to set the temperature control meter
1. Turn on the power supply of the smart thermostat, and the temperature displayed on the screen is the temperature at that time. Because the sensor is not in contact with other devices, but is directly exposed to the air clock, this is the current temperature: 31 degrees Celsius, which is not too hot.
2. At the bottom right of the display screen is the "starting temperature" setting ...
|
|
RHK thermostat - the use of electronic thermostat and its classification introduction
First, the use of electronic temperature controller
The electronic temperature controller (resistive type) is measured by the method of resistance temperature sensing, and generally uses platinum wire, copper wire, tungsten wire and semiconductor (thermistor, etc.) as the temperature measurement resistor, and these resistors have their own advantages and points. Home Air Conditioner ...
|
|
Introduction to the functions of the RKC temperature control meter
(1) RH400 size: 48*96, depth 60, about 250g
Details:
●A variety of input types are available:
1) Thermocouples: K, J, R, S, B, E, N, T, W5RE/W6RE, PL‖, U, L
2) Temperature measurement RTD input: PT100, JPT100...
|
|
RLC thermostat – what is the difference between a mechanical thermostat and an electronic thermostat
Mechanical thermostat mainly refers to a temperature control method that adjusts refrigeration by rotating the button, with an expanding thermostat, which will automatically expand and contract according to the change of temperature, so as to control the power supply, the most primitive type, and the structure is relatively simple.
Advantages of mechanical thermostats:
...
|
|
RKC thermostat - introduction of three wiring methods of thermal resistance
1. The three wiring methods of Pt100 RTD are different in principle:
The two-wire system and the three-wire system are measured by the bridge method, and the relationship between the temperature value and the analog output value is given after ***. There is no bridge on the four wires, it is completely just sent with a constant current source, measured by a voltmeter, and the test is given after *** ...
|
|
RHK thermostat - common faults and maintenance methods of thermostats
1. Thermostat contact contact failure
Poor contact of the thermostat contacts will cause the compressor to not operate properly. If the contacts are sticky, the compressor will fail without downtime. For this, you can use a small screwdriver to open the metal shell of the thermostat, and then use a fine abrasive cloth to polish the surface of the contacts ...
|
|
A few things to note about the installation of the RKC thermostat
1) For RTD input, 3 wires with low resistance and no difference should be used.
2) The input signal line should be far away from the power line of the instrument, the power supply line and the load line to avoid noise and annoyance.
3) The power cord of the instrument is generally annoyed by the power supply.
4) Instrument complement ...
|
|
RHK thermostats – an introduction to the classification of displays
(1) Categorize by display color
1. Monochrome display
There are two types of displays: multi-grayscale monochrome display and VGA multi-frequency monochrome display. These displays are small, lightweight, clear and inexpensive, making them suitable for highly mobile workplaces.
2. Color ...
|
|
RKC converter – the control strategy of the converter
Direct transformation method
The direct conversion method is to synthesize the "output voltage" through the continuous chopping of the input voltage, which can be divided into coordinate transformation method, harmonic injection method, equivalent conductivity method and scalar method, although all these methods have certain advantages, but also have certain problems, ...
|
|
RRKC thermostats – how are temperature controllers wired and commissioned?
1. Take out the room temperature controller, and then connect the power supply terminal of the temperature controller to the power supply according to the terminal diagram of the temperature control chart
2. Then take out the temperature sensor that comes with the temperature controller and detect it
3. According to the temperature controller terminal, the temperature sensor is connected to the controller's transmission.
|
|