Misunderstandings of power-saving and energy-saving use of inverters

Create Date: 2024-8-30 12:03:23|Source: Delta/Delta

Industrial control automation products inverters are depicted as power-saving, energy-saving control automation products, therefore, many people will think that as long as the equipment is installed with inverters, it will be able to save energy, but this is not the case.

The inverter of industrial automation products itself produces the understanding that energy saving and power saving is a fault. Whether the inverter of industrial automation products can achieve the role of power saving and energy saving also needs to be determined according to the actual situation of use.

                              Misunderstandings of power-saving and energy-saving use of inverters

Myth 1: Many people think that the torque of the two motors does not reach the extra torque of the motor (frequency, speed is still the same 50HZ), and the inverter of industrial automation products will also play a role in energy saving, which is a mistake.

Myth 2, two identical motors are operating in the power frequency state of 50HZ, one uses the inverter, the other does not, and the speed and torque are in the additional state of the motor, I believe that most people will think that the motor using the inverter will be more energy-saving and power-saving. In fact, this is also a kind of faulty thinking.

Myth 3: Under the same conditions, many people think that they can save a lot of electricity in the no-load state, but in fact, the no-load state of the dragged load can not save much electricity.

The reason why the inverter of industrial automation products can achieve the role of power saving and energy saving in most cases is that the inverter controls the speed of the motor, but in fact, most of the speed regulating equipment can achieve this role, because it is obvious that we can not identify the inverter as an energy-saving product.

More on that
Touch screen controls the inverter step – Delta Touch screen controls the inverter step – Delta

1. The touch screen is controlled by PLC inverter 1. At present, the general control of the inverter needs to choose PLC to communicate with the inverter, read the information of the inverter, and then the touch screen communicates with the PLC to complete the control of the inverter to start, stop, and monitor the operation of the inverter.

Delta's Ultron HPH provides power protection that meets the needs of green data centers Delta's Ultron HPH provides power protection that meets the needs of green data centers

Delta's Ultron HPH series UPS has an AC-AC efficiency of up to 96%, and can reach 99% in ECO mode, with significant energy savings. The flexible airframe provides a compact footprint (40kW / 0.15 m2) and reduces space waste. With an interface-friendly 5-inch colorful touch screen, ...

Delta's inverter fault warning solution Delta's inverter fault warning solution

Product series: CP/CH/CT/C2000/C200/MS300/MH300/VE/ED/VJ Fault Codes: noCL Fault clarification: The lack of oil is correct Solution: 1. Check the fuel level of the fuel tank 2. Check whether there is any leakage on the oil road.

Delta's PLC-Based motion controller AX3 series Delta's PLC-Based motion controller AX3 series

With the development of electronic semiconductor information technology, technologies such as the Internet of Things, big data, and cloud channels are showing a trend of hundreds of schools of thought, which also drives the rapid development of intelligent production. Intelligent production also puts forward new requirements for controllers: high speed, large capacity, miniaturization, networking...... In order to ...

The basic methods and steps of inverter debugging - Delta inverter The basic methods and steps of inverter debugging - Delta inverter

1. No-load energizing test of inverter 1. Ground the grounding terminal of the inverter. 2. Connect the power input terminal of the inverter to the power supply through the leakage maintenance switch. 3. Check whether the factory display window of the inverter is normal, if it is incorrect, it should be reset, no ...

Common problems of VFD control motors - Delta Common problems of VFD control motors - Delta

Question 1. Why use a VFD to control the motor? Speaking of this question, let's first take a brief look at these two devices. The motor is a rational load, which hinders the change of current, and a large change in current will occur when it is started. VFD, which is actually made up of a rectifier inverter circuit, ...

Delta inverter repair steps Delta inverter repair steps

Delta inverters still have a certain influence in the industry, but even if the reputation is good, it will inevitably show some failures. Let's take a look. ...

Delta's key steps in inverter maintenance Delta's key steps in inverter maintenance

First, the maintenance of the inverter must first check whether the sound in the operation of the motor is abnormal, including, whether the motor is in operation to form a sensation. ​ 2. Check whether the natural environment of the inverter installation has changed. ...

Delta's inverter method to reduce the failure rate Delta's inverter method to reduce the failure rate

Daily inspection item 1 of Delta's inverter problem repair: Check whether there are any abnormal changes in the sound of the motor during operation, including whether there is vibration during the operation of the motor. Routine inspection item 2 of Delta inverter problem repair: Check out the inverter installation environment is ...

Excessive inverter capacity poses a hazard to electrical equipment – Delta Excessive inverter capacity poses a hazard to electrical equipment – Delta

(1) The harmonic current will directly cause the additional heating of the motor, so that the stator of the motor will exceed the rated temperature rise of the motor itself, so that the rated output capacity of the motor will be greatly reduced. ​ (2) The current wave output of the inverter ...

Delta's inverter external positive and reverse operation mode Delta's inverter external positive and reverse operation mode

1. The external control panel is rotated and operated After selecting the upper or lower button on the panel, the Frd inverter will rotate forward if you select the inverter, and the rEu inverter will rotate 2. The external control terminal is rotated Access via external terminals ...

Precautions for long-term idle inverter - Delta inverter Precautions for long-term idle inverter - Delta inverter

If the inverter is to run the equipment again after being shelved for more than half a year, the probability of damage may be greatly increased due to many factors such as the placement environment, the service life of the inverter, and the load rate, and the failure usually presents the following problems: ...

The peripheral equipment of the inverter governor - Delta The peripheral equipment of the inverter governor - Delta

When installing the inverter governor, it is necessary to first understand its use occasions and set up different peripheral equipment according to the needs of the site. The primary peripheral equipment of frequency governor is: air circuit breaker, electromagnetic contactor, communication reactor, braking resistor, DC reactor, output communication reactor, wireless ...

Delta inverter failure and maintenance Delta inverter failure and maintenance

Delta's inverter problem 1: Communicate with the motor driver to explore the formation of overvoltage conditions on the internal DC high-voltage power supply side Check whether the keyed operating voltage is in the field of the additional value of the communication motor driver keying operating voltage, and detect whether there is a surge operating voltage formation If it is due to ...

Delta's powerful NT series industrial-grade UPS Delta's powerful NT series industrial-grade UPS

Delta's NT series industrial-grade UPS has always been an ideal choice for applications that require high power safety due to their high reliability and high-density planning. IGBT high-frequency switching sinusoidal pulse width modulation technology planning, which makes UPS have good power supply quality, high efficiency, low heat loss, noise ...

EMC Filter Installation Considerations – Delta EMC Filter Installation Considerations – Delta

All electronic equipment (including frequency converters) will generate some high-frequency or low-frequency noise during normal operation, and disturb the peripheral equipment through conduction or radiation. If the right EMC filter can be configured and the correct device method can be used, the disturbance can be reduced to a minimum. ...

Use and maintenance of electric motors - Delta motors Use and maintenance of electric motors - Delta motors

The motor can be started after the work is completed before use, and attention should be paid to the investigation of the motor, transmission device, production machinery and line voltage and ammeter, if there is an abnormal phenomenon, it should be stopped immediately, the fault should be identified and swept away, and then it can be closed and started again. When the motor is running, ...

Reduce the failure rate of Delta's inverters Reduce the failure rate of Delta's inverters

Daily View Item 1: Check whether the sound of the motor changes abnormally during operation, including whether there is vibration during the operation of the motor. Project 2: Check if the environment of the inverter unit has changed. For example, whether the ambient temperature is normal. Familiar with Delta's inverter ...

Delta's high-performance servo ASDA-A3 series is a new product Delta's high-performance servo ASDA-A3 series is a new product

With the rapid development of automation technology and shopping malls, customers have higher and higher requirements for the speed, accuracy and function diversification of servo products. In order to get used to the needs of shopping malls, recently, Delta launched the high-performance motion control high-end AC servo system ASDA-A3 series ...

Delta's inverter adjusts the motor speed mode Delta's inverter adjusts the motor speed mode

The speed control on Delta's inverter is mainly as follows: 1. Adjust the variable resistance directly from the surface of the Delta inverter 2. External analogue voltage or current signal to adjust 3. Take advantage of the multi-function of the inverter ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top