With the rapid development of automation technology and shopping malls, customers have higher and higher requirements for the speed, accuracy and function diversification of servo products. In order to meet the needs of shopping malls, recently, Delta launched the ASDA-A3 series of high-end AC servo systems with high-performance motion control. With its technical advantages of extreme speed, accuracy, stability, high efficiency and energy saving, this series of products has attracted wide attention from shopping malls and has become a new choice for customers to realize the transformation and promotion of equipment and industry.
Main features of the product:
Performance. The ASDA-A3 series has a 3kHz speed response bandwidth, which is up to 3 times higher than Delta's ASDA-A2 series, making command tracking more timely. The motor is equipped with a 24-bit resolution*** encoder with a singleturn resolution of 16,777,216 pulses, making the positioning more accurate. Support high speed of 6000r/min, 350% overload torque, production capacity and acceleration are increased synchronously;
Multi-functional. The ASDA-A3 series has a new flexible compensation and high and low frequency vibration suppression functions, which can solve the shaking phenomenon of flexible structure and end structure, effectively press the resonance of mechanical structure, and shorten the setting time. The built-in Safe Torque Off (STO) function makes the device more comprehensive;
Built-in advanced operation control function. The ASDA-A3 series adopts the advanced PR mode, which is amplified to 99 motion commands, which can facilitate users to flexibly plan single-axis motion control. It supports the functions of electronic cam, flying shear and chasing shear, and can be used for flying shear, chasing shear and other master-slave use occasions;
Energy-saving and miniaturized design is selected. ASDA-A3 series drivers can share DC bus, and the regenerative energy can be reused; Compared with Delta's ASDA-A2 series, the surface width is reduced by up to 20%, effectively saving the installation space of electrical cabinets. The supporting servo motor is also shortened by up to 20% compared with the ASDA-A2 series, making it possible to miniaturize the equipment.
The software interface is friendly. The ASDA-A3 series software interface uses a tree-like structure, which is easy to click and easy to use. The parameter setting is based on the drawing type, which supports the automatic gain adjustment function, advanced gain adjustment function, etc., and the interface is more friendly and convenient, without the need for cumbersome adjustment operations.
Delta's high-performance servo system ASDA-A3 series can be widely used in machine tools, electronic assembly or testing equipment, industrial robots, packaging equipment, labeling equipment, semiconductor equipment, textile equipment and other mechanical fields.
|
More on that
|
The case of Delta's multi-axis motion controller
The non-standard manipulator can be customized according to the practical needs of customers, because the non-standard manipulator has no specifications to follow, and there is no such kinematic model in the controller, so the development of the control system is difficult. Delta recently provided non-standard manipulators for pharmaceutical board manufacturers to supply control solutions ...
|
|
Delta inverter fault alarm code and solution
The OCC AC motor driver detects an unusual overcurrent surge on the output side
See if the motor extra matches the communication motor drive extra
Check whether there is a short circuit between the communication motor driver U-V-W
View...
|
|
Delta's DTK series thermostat product model
DTK4848C01 High brightness LCD display, 48*48, Pt resistor/thermocouple input, 4-20mA output, 1 alarm
DTK4848R01 High brightness LCD display, 48*48, Pt resistor/thermocouple input, relay output, 1 alarm
DTK4848V01 Highlight ...
|
|
Introduction to the common sense of Delta inverter
The low-voltage fuse cannot be used as an overload maintenance for the motor.
It is necessary that the additional voltage of the fuse is greater than or equal to the operating voltage of the distribution line.
The additional current of the fuse must be greater than or equal to the additional current of the melt.
...
|
|
Delta's active front-end and inverter's coordination
The popularity of frequency converters has brought significant energy savings to industrial applications. However, the high-frequency switching signal generated by the inverter is easy to cause electromagnetic interference and affect the power quality. Especially in industries with large loads such as lifting and elevators, it is becoming more and more obvious.
...
|
|
Delta's power supply series application considerations
(1) Considering that the power supply is inconsistent at the time of power-on, the load is short-circuited, and the rational load may present a reverse voltage, the output end of each power supply connected in series should be set up with two anti-parallel tubes, and the forward additional current of the two * tubes should not be less than the additional output current of the power supply, and the reverse breakdown voltage should not be less than ...
|
|
Delta linear motor driver ASDA-A2R series
In view of the rapid transformation of the industry, Delta has specially proposed a total linear motor solution, deploying various communication interfaces, extending the evolved model ASDA-A2R from ASDA-A2 as a linear horse driver, and deploying Delta's high-speed bus controller and axis card to form a complete linear motor ...
|
|
Delta's SCARA industrial robots help replace machines in the electronics manufacturing industry
Project Background
At present, electronic products such as mobile phones, computers, and IPads have become the standard in people's lives, which also promotes the rapid development of the electronic manufacturing industry. PCB (printed circuit board) is an important component in electronic products, with the trend of electronic products towards high-end, miniaturization ...
|
|
Delta servo problem analysis
1: What is the difference between servo motor and general motor?
The biggest difference between servo motors and general motors is the motor rotor and reaction equipment. The surface of the servo motor rotor is pasted with a strong magnetic plate, so that the magnetic field generated by the stator coil can control the orientation of the rotor, and the acceleration and deceleration characteristics are ...
|
|
Set the parameters when reading and uploading the Delta PLC program
Open Delta's programming software, and use WPLSOFT to do the demo here;
First, click on the settings and then click on the communication settings in the settings, select the communication mode, communication port, communication baud rate, communication station number, etc.
After the setting is finished, click OK to automatically close the pop-up window.
In the dish ...
|
|
The principle structure of low-voltage circuit breaker - Delta
Low-voltage circuit breakers, commonly known as active air switches, are one of the primary electrical switches in low-voltage distribution networks. It can not only turn on and off normal load current, motor operation current and overload current, but also turn on and off short circuit current.
It is mainly used as a low-voltage distribution line or a switch cabinet that is not often operated ( ...
|
|
Precautions for Delta inverter C2000 series
1. Precautions for choosing a communication motor driver
When using a large-capacity current transformer (more than 600kVA) and a phase-entering capacitor, the surge current on the input side of the power supply is too large, which may destroy the input side of the communication motor driver.
|
|
Delta inverter parameter replication error solved
1. SE2 parameter imitation error
Problem Description:
Keypad Imitation Function Fault Correction 2
Solution:
1. The Keypad imitation action is completed, and the inverter parameters are written into error
2. SE1 Parameter Imitation ...
|
|
Advantages of Delta inverters
1. Control the starting current of the motor: when the motor is directly started through the I frequency, it will generate 7 to 8 times the rated current of the motor, and this current value will greatly increase the electrical stress of the motor winding and generate heat, thereby reducing the life of the motor. The acid frequency speed regulation can be started at zero speed and zero voltage (can also be ...
|
|
Delta's active front-end inverter partner
The ubiquity of AC drives brings significant energy savings to industrial applications. However, the high-frequency switching signal generated by the inverter is easy to form electromagnetic disturbance, which affects the power quality. It is especially significant in occupations with large loads such as lifting and elevators.
At this time, the inverter ...
|
|
Delta's inverter and output reactor function
input/output reactor for frequency conversion speed regulation; Because the inverter is often affected by the impact of inrush current and surge voltage in the process of driving the inverter motor operation governor, which will seriously damage the function and service life of the inverter and the motor, so it is necessary to install a transmission system in front of it.
|
|
Workarounds for industrial tablet PC disk failures
After the long-term operation of the industrial tablet, there is a lot of dust in the chassis and the temperature of the chassis is high. At this time, it is very simple to cause the disk failure of the industrial tablet computer, the product quality problems of the hard disk itself and the failure problems caused by the working environment.
...
|
|
Introduction to Delta Inverter VFD-C200 Series
Delta's VFD-C200 series inverters adopt the design concept of ultra-miniature structure: small size, compact structure, reliable performance, and optimal heat dissipation design, which is convenient for users to install and debug. Taking into account the possibilities of the industrial production environment, this inverter is made of special materials and complies with the requirements of the IEC...
|
|
Inverter optocoupler device type - Delta
1. One is a triode type photocoupler, such as PC816, PC817, 4N35, etc., which is commonly used in the output voltage sampling and error voltage amplification circuit of the switching power supply circuit, and is also used in the digital signal input loop of the inverter control terminal. The structure is the simplest, and the input side consists of a light-emitting two...
|
|
Precautions for the inverter installation environment – Delta
(1) Ambient temperature:
Like other electronic equipment, the inverter has certain requirements for the ambient temperature, which is generally "-10-+40°C". Because the inverter is a high-power electronic equipment, it is very easy to be affected by the working temperature, but in order to ensure the safety of the inverter's work.
|
|