Delta's inverter fault warning solution

Create Date: 2024-8-30 12:03:23|Source: Delta/Delta

Product series: CP/CH/CT/C2000/C200/MS300/MH300/VE/ED/VJ

Fault Codes:

  noCL

Fault clarification:

The lack of oil is correct

Solution:

1. Check the fuel level of the fuel tank

2. Check whether there are leaks and other problems on the oil road

3. If there is an oil pump into the oil port filter, check whether there is any blockage

                               Delta's inverter fault warning solution

Product series: CP/CH/CT/C2000/C200/MS300/MH300/VE/ED/VJ

Fault Codes:

  PrEu

Fault clarification:

The oil pump is reversed

Solution:

1. Check whether the pressure sensor has zero drift and whether the wiring is correct

More on that
How does Delta inverter adjust the frequency? How does Delta inverter adjust the frequency?

  Delta's frequency modulator frequency modulation is mainly operated on the control panel, and the process: 1. Press the Menu button to enter the parameter programming menu,   ​   2,P0.01=1,Enter this parameter to complete the correction frequency of the panel button, ...

Productivity maintenance tips for Delta drives Productivity maintenance tips for Delta drives

1. When the Delta inverter breaks down in the future, it is best not to hand it over to someone who has no experience in repairing the inverter to repair the inverter, otherwise it may get worse and worse. Sometimes it's about to fuse, be sure to check whether there is a problem with the module, some electricians have not experienced it, and immediately install a good fast melt (definitely not ...

Solution to Delta's overload trip fault Solution to Delta's overload trip fault

1. The main reason for VFD overload (1) Mechanical overload. The main characteristic of overload is the heating of the motor, which can be detected by reading the operating current on the display. (2) The three-phase voltage imbalance leads to excessive running current in a certain phase, resulting in overload tripping. It is characterized by uneven heating of the motor ...

Precautions for the installation environment of the inverter - Delta inverter Precautions for the installation environment of the inverter - Delta inverter

(1) Ambient temperature: The inverter is the same as other electronic equipment, and has certain requirements for the ambient temperature, which is generally "-10-+40°C". Because the inverter is a high-power electronic equipment, it is easy to be affected by the operating temperature, but in order to ensure the safety of the inverter...

Inverter selection point - Delta Inverter selection point - Delta

1. When selecting the inverter, select the inverter with the appropriate control method according to the load characteristics In addition to the inverter manufacturing process, it is also important to use the inverter's control method. The control methods of the inverter are mainly divided into two types: open-loop control and closed-loop control. In the meantime, the open-loop control method ...

Workarounds for industrial tablet PC disk failures Workarounds for industrial tablet PC disk failures

  After the long-term operation of the industrial tablet, there is a lot of dust in the chassis and the temperature of the chassis is high. At this time, it is very simple to cause the disk failure of the industrial tablet computer, the product quality problems of the hard disk itself and the failure problems caused by the working environment. ...

Detection methods for Delta circuit breakers, AC contactors and frequency converters Detection methods for Delta circuit breakers, AC contactors and frequency converters

1. Circuit breaker A circuit breaker is a device that can be manually or automatically controlled, and is used to control the on/off of the system power supply in the equipment circuit system. When there is a suspicion that there is a defect in the electrical system of the equipment, the primary functional part of the power supply should be checked. Under normal circumstances, when in the ON state, the input input ...

Introduction to Delta Inverter VFD-C200 Series Introduction to Delta Inverter VFD-C200 Series

Delta's VFD-C200 series inverters adopt the design concept of ultra-miniature structure: small size, compact structure, reliable performance, and optimal heat dissipation design, which is convenient for users to install and debug. Taking into account the possibilities of the industrial production environment, this inverter is made of special materials and complies with the requirements of the IEC...

Application of Delta A2 servo on packaging twisting machine Application of Delta A2 servo on packaging twisting machine

Double-end twisting machine is a more traditional sugar block packaging machine, it is widely used in small and medium-sized sugar block production enterprises, with a high degree of automation, which can not only complete the packaging of single or multi-layer paper, but also can package a variety of shapes of hard candy or soft candy.

Solution: Delta's inverter operation error Solution: Delta's inverter operation error

There are many setting parameters of the inverter, each parameter has a certain selection scale, and the inverter can not work normally due to the improper setting of a single parameter is often encountered in the application, therefore, the relevant parameters must be set correctly. ...

Inverter optocoupler device type - Delta Inverter optocoupler device type - Delta

1. One is a triode type photocoupler, such as PC816, PC817, 4N35, etc., which is commonly used in the output voltage sampling and error voltage amplification circuit of the switching power supply circuit, and is also used in the digital signal input loop of the inverter control terminal. The structure is the simplest, and the input side consists of a light-emitting two...

Delta's PLC-Based motion controller AX3 series Delta's PLC-Based motion controller AX3 series

With the development of electronic semiconductor information technology, technologies such as the Internet of Things, big data, and cloud platforms are showing a trend of hundreds of schools of thought, which also drives the rapid development of intelligent production. Intelligent production also puts forward new requirements for controllers: high speed, large capacity, miniaturization, networking...... In order to ...

The technical advantages of the three-axis positioner - Delta The technical advantages of the three-axis positioner - Delta

1. The welding station is actively handed over, and the operator has been loading and unloading parts in a fixed position, which effectively reduces the labor and logistics intensity of the operator, and the welding products of the whole set of equipment have strong compatibility and strong automatic welding scalability. 2. All ...

Precautions for the operation of Delta servo motors Precautions for the operation of Delta servo motors

1) The AC servo motor works by means of a dedicated drive. Do not connect the commercial power supply (100/200V, 50/60Hz) directly to the line of the servo motor, otherwise the servo motor will not work properly and the servo motor will be permanently damaged. ...

Precautions before installation of Delta inverters Precautions before installation of Delta inverters

Delta's inverter should be thoroughly inspected for initial installation or long-term use. The items and methods to check are as follows: 1) Check whether the Delta inverter is damaged, whether the metal parts are rusty, and whether there is frost. If there is frost and condensation, it should be dry for 4 hours (60°C) or in ...

The inverter reported the cause of the grounding fault - Delta The inverter reported the cause of the grounding fault - Delta

Regarding the grounding problem, it can generally be swept away after the following steps (because most of the inverters are not easy to detect the current measurement of Hall components, it is very important to sweep the grounding caused by external conditions, and alternative methods can be selected if there are conditions, and it is still an external problem to change a normal load to see whether it is a problem of frequency conversion or an external problem ...

Wind turbine inverter speed regulation effect - Delta Wind turbine inverter speed regulation effect - Delta

What is the effect of speed regulation of fan inverter? According to the query materials, in industrial production, the throttling loss of the damper, baffle and other related equipment of the fan, as well as the protection and maintenance costs account for 7%-25% of the production cost.

Delta's PLC-Based motion controller AX3 series Delta's PLC-Based motion controller AX3 series

With the development of electronic semiconductor information technology, technologies such as the Internet of Things, big data, and cloud channels are showing a trend of a hundred flowers blooming, which also drives the rapid development of intelligent production. Intelligent production also puts forward new requirements for controllers: high speed, large capacity, miniaturization, networking...... In order to ...

Delta inverter repair steps Delta inverter repair steps

Delta inverters still have a certain influence in the industry, but even if the reputation is good, it will inevitably show some failures. Let's take a look. ...

Delta's soft starter component role Delta's soft starter component role

The soft starter is a device used to control the start and stop of the motor, which is composed of a number of components, including the soft starter controller, the soft starter conditioner, the soft starter power supply, the soft starter input and output module, the soft starter interface module, etc. ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top