When installing the inverter governor, it is necessary to first understand its use occasions and set up different peripheral equipment according to the needs of the site. The primary peripheral equipment of frequency governor is: air circuit breaker, electromagnetic contactor, communication reactor, braking resistor, DC reactor, output communication reactor, wireless noise filter and so on.
The peripheral equipment of the inverter governor is described in detail as follows:
1. Air circuit breaker is an active electrical appliance that can not only contact and disconnect the circuit normally, but also operate under abnormal conditions such as overcurrent, reverse current, short circuit and loss (under)voltage. Its primary role is to maintain the electrical equipment in the AC and DC circuits, and it is also able to operate the circuit infrequently. It is used to quickly block the frequency converter governor and avoid power supply problems caused by line problems.
2. The communication reactor, also known as AC reactor and communication reactor for power supply coordination, is primarily used to avoid harmonic disturbance in the power grid.
3. The communication contactor is referred to as the contactor, which is used to shield the active electrical appliances used to shield the long-distance connection and separation of AC and DC circuits, or large capacitance control circuits, and is mainly used for actively blocking the main power supply and avoiding power failure and failure when there is a problem with the frequency converter.
4. The radio noise filter, also known as the power filter, is primarily used to suppress the conduction of radio signals from the metal pipeline into the equipment, or to suppress the transmission of the disturbance signal from the disturbance source equipment through the power supply.
5. The DC reactor is mainly to suppress the higher harmonics generated by the frequency conversion governor, and its effect is better than that of the communication reactor.
6. The output communication reactor is also known as the output side anti-disturbance filter, which is a filter that suppresses the influence of high-frequency disturbance filter on the power supply side.
7. The filter hood is mainly to prevent dust from entering the frequency converter.
|
More on that
|
The reason for the low voltage trip of the inverter - Delta
The low voltage of the inverter mainly refers to the low voltage of the central DC circuit, and the reasons for the low voltage of the central DC circuit generally come from two aspects:
(1) Low voltage from the input side of the power supply
The power supply under normal conditions ...
|
|
Features of two-phase electric fan inverter - Delta
With the continuous development of science and technology, there are more and more types of domestic machinery and equipment, and the upgrading of equipment is getting faster and faster. So what are the characteristics of two-phase electric fan inverter and whether it is worth choosing for enterprises. ...
|
|
The case of Delta's multi-axis motion controller
The non-standard manipulator can be customized according to the practical needs of customers, because the non-standard manipulator has no specifications to follow, and there is no such kinematic model in the controller, so the development of the control system is difficult. Delta recently provided non-standard manipulators for pharmaceutical board manufacturers to supply control solutions ...
|
|
Common problems of VFD control motors - Delta
Question 1. Why use a VFD to control the motor?
Speaking of this question, let's first take a brief look at these two devices. The motor is a rational load, which hinders the change of current, and a large change in current will occur when it is started. VFD, which is actually made up of a rectifier inverter circuit, ...
|
|
Precautions for summer maintenance and maintenance of inverters - Delta
1. Check the operating status of the inverter, whether the voltage and current value during operation are within the normal range.
2. Carefully monitor and record the ambient temperature of the frequency conversion room, and the ambient temperature is generally between -10 °C and 40 °C. The temperature rise of the phase-shifting transformer should not exceed 130°C.
3. Avoid ...
|
|
How to use Delta's inverter operation
(1) When the speed of the motor is controlled by the Delta inverter, the noise and temperature rise of the motor are higher than that of the frequency of the motor. When the motor is running at low speed, because the speed of the motor blades is low, the temperature rise of the motor becomes high.
|
|
Delta's inverter failure analysis
1. Fault code:
SE1 parameter replication error
Fault Description:
Keypad replication function error correct
Solution:
Keypad replication action errors, including communication delays, communication errors (Keypad received FF86 errors), and parameter value errors
...
|
|
The role and application of Delta's thermostats
Delta's thermostat is a commonly used temperature control device, which can adjust the temperature according to the user's needs, and then achieve the intention of saving energy. The effect and use of Delta thermostats are also very widespread, so let's introduce the effects and uses of Delta thermostats.
...
|
|
Whether the inverter needs to be added to the line - Delta
The role of the "communication input reactor" of the inverter input device is mainly to improve the power factor of the communication power supply on the communication side of the input side; It is useful to eliminate the higher harmonics on the input side to avoid damage to other electrical equipment caused by voltage distortion; Eliminate the three-phase AC power phase ...
|
|
How to quickly master Delta servo?
1: What is the difference between servo motor and general motor?
The biggest difference between servo motors and general motors is the motor rotor and reaction equipment. The surface of the servo motor rotor is pasted with a strong magnetic steel sheet, so that it can be produced by the stator coil.
|
|
Instrument classification standard - Delta
The appearance of the instrument is a comprehensive product of a variety of science and technology, with a wide variety of varieties, wide application, and constantly updated, with a variety of classification methods. According to the intention and use of the use of the main measuring instrument, car appearance, tractor appearance, marine appearance, aviation appearance, navigation instruments, control instrument ...
|
|
Composition and function of Delta inverter
Delta inverter is a device that converts the power supply (50Hz or 60Hz) into AC power supply of various frequencies to realize the variable speed operation of the motor.
|
|
Delta's Smart series of micro-modules help transform high-speed tunnel networks
Recently, Delta's Smart series of micro-modular data center processing solutions successfully assisted the smooth implementation of a provincial tunnel network transformation project in a province. The project has set up a series of safety operation networks such as video, lights, signals, networks, rescues, and alarms for the safe operation of key roads in the province.
|
|
Delta's Ultron NT series UPS escorts flight safety at international airports
The rapid development of the national economy has opened up a broad shopping mall space for the growth of the civil aviation industry. In order to meet the surge in the number of flights, an international airport in Northwest China has invested in the third phase of the expansion project, and has been listed as the "number one project" for civil aviation development and the "benchmark demonstration project" for national civil aviation.
|
|
Delta's inverter adjusts the motor speed mode
The speed control on Delta's inverter is mainly as follows:
1. Adjust the variable resistance directly from the surface of the Delta inverter
2. External analogue voltage or current signal to adjust
3. Take advantage of the multi-function of the inverter ...
|
|
The benefits of using an inverter – Delta inverter
1. Speed regulation of general motor: By changing the input voltage and frequency of the three-phase asynchronous motor, its speed can be controlled. Generally, when the motor is at low speed, the temperature rise becomes larger due to the decrease in the power of the cooling fan, and the motor load should be reduced according to the frequency.
2 ...
|
|
Ways to reduce the failure rate of Delta drives
If you want to reduce the fault rate of Delta inverter, it is necessary to check it daily, and what are the detailed items?
Delta inverter fault repair ...
|
|
When the Delta inverter is powered on, the uptube drive voltage is established
One is hardware, similar to the CPU reset circuit, which gives the downtube a short high-level drive pulse during the initial power-up, and then the voltage drops to 0 to cut off the downtube.
The second is the software, when the CPU is operating normally, it outputs a square wave pulse that only needs to be turned on by the lower three tubes, so that the upper tube ...
|
|
Precautions for inverter selection - Delta
The selection of the inverter is mainly determined by the load characteristics of the drive and the actual working current of the motor, in addition to the following precautions:
1. The environment is suitable for some high temperature (higher than 50 degrees) and high altitude (higher than 1000 meters).
|
|
Troubleshooting of small electromagnetic relay cores - Delta
The main problems of the iron core of the small electromagnetic relay are that the armature cannot be sucked after being electrified:
This may be due to broken coils, foreign matter between the moving and static cores, and low power supply voltage. It should be patched on a case-by-case basis.
When energized, the armature is noisy:
This may be because of the ...
|
|