Delta's Ultron HPH series UPS has an AC-AC efficiency of up to 96%, and can reach 99% in ECO mode, with significant energy savings. The flexible airframe provides a compact footprint (40kW / 0.15 m2) and reduces space waste. Paired with an interface-friendly 5-inch colorful touchscreen for easy and straightforward handling, UPS status is an aspirational solution for a wide range of small and medium-sized data centers and critical backup power supplies.
Ultron HPH Gen.1 Series has won multiple awards in different industries around the world since its launch in 2013, and the Gen.2 Series continues to build on a generation of advanced planning, delivering more than 96% efficiency, combined with reliable power maintenance, high economics, and a compact footprint to demonstrate superior performance.
Faster return on investment
The Ultron HPH series is a high-efficiency UPS with over 96% efficiency in its class, helping to reduce energy consumption and operating expenses, enabling users to meet sustainability goals together with high availability. In addition, the Ultron HPH series offers a wider selection of battery configurations (30-46 units) to optimize the cost of battery installation.
Compact planning, easy to arrange and maintain
Advanced technology and heat dissipation allow for preemptive power density without compromising output power, full rated power output at ambient temperature of 40°C, with a smaller footprint and manually operated maintenance switches in a single unit enclosure.
High flexibility makes it easy to handle
The Ultron HPH Series offers a user-friendly 5-inch colorful touchscreen for easy and direct UPS. The built-in 15A charger can achieve a long-term redundancy solution without incurring additional costs. In addition, the Ultron HPH series provides critical part replacement alarms and uses a countdown timer to inform the user of component expiration dates. For customers who use it in harsh environments, we also offer an optional IP42 kit to meet the diverse needs of customers.
|
More on that
|
Delta's PLC-Based motion controller AX3 series
With the development of electronic semiconductor information technology, technologies such as the Internet of Things, big data, and cloud channels are showing a trend of hundreds of schools of thought, which also drives the rapid development of intelligent production. Intelligent production also puts forward new requirements for controllers: high speed, large capacity, miniaturization, networking...... In order to ...
|
|
Delta's Amplon N series UPS ensures the safety of electricity consumption in pharmaceutical production lines
In recent years, in response to the development trend of automation, informatization and intelligence, pharmaceutical companies have continuously innovated, transformed and upgraded, selected fully automated intelligent production lines, accelerated the upgrading of equipment in the pharmaceutical industry, and completed the use of smart pharmaceutical technology for green, safe, high-quality and low-consumption development in the pharmaceutical industry.
|
|
Installation requirements for inverter energy consumption braking - Delta inverter
(1) The wiring interval between the braking unit and the inverter, as well as between the braking unit and the braking resistor, should be as short as possible (the wire length should be less than 2m), and the wire cross-section should meet the requirements of the braking resistor discharge current.
(2) The brake unit is working ...
|
|
How to quickly master Delta servo?
1: What is the difference between servo motor and general motor?
The biggest difference between servo motors and general motors is the motor rotor and reaction equipment. The surface of the servo motor rotor is pasted with a strong magnetic steel sheet, so that it can be produced by the stator coil.
|
|
Delta's inverter external positive and reverse operation mode
1. The external control panel is rotated and operated
After selecting the upper or lower button on the panel, the Frd inverter will rotate forward if you select the inverter, and the rEu inverter will rotate
2. The external control terminal is rotated
Access via external terminals ...
|
|
Basic parameter setting of special inverter for wind turbine - Delta
1. Control mode:
i.e. speed control, torque control, PID control or other methods. After the control method is adopted, static or dynamic identification should generally be carried out according to the control accuracy.
2. Minimum operating frequency:
That is, the minimum speed of the motor. When the motor is working at low speed, the ...
|
|
Delta's LOYTECIoT building management platform helps Yili Group reduce costs
Intelligent houses are selected with fully automatic automatic control systems to consider the diverse requirements of community owners, managers and users in housing management methods. In the new project of Yili Group's Food Science R&D Trend Management Center, under the framework of opening to the outside world, Damei has made use of Loytec ...
|
|
Inverter power-on panel without display fault analysis - Delta
In the inverter problem, it is often encountered that the energized panel does not appear. Generally speaking, the problem of the inverter panel not showing up is usually caused by three parts, one is the poor contact of the contactor, the second is the control panel of the inverter, and the third is the damage of the power module that supplies power to the control panel.
|
|
The impact of inverter cable design on the life of motor cables
Reflected waves that affect the impedance mismatch between the cable and the motor are pervasive in all AC VFD applications. The severity of the problem depends on the length of the cable, the rise time of the PWM (Pulse Width Modulation) carrier, the voltage of the VFD, and the magnitude of the impedance difference between the motor and the cable.
...
|
|
Introduction to Delta's RH series switching power supply
Delta's RH series switching power supply, RH series switching power supply is a high-quality power supply product series planned by Delta Power for industrial applications, with the characteristics of high rate, high reliability and high function. This series of products has a wide range of input voltages and can be applied to a variety of power input ...
|
|
Description of Delta inverter problems and solutions
Problem Description:
What is stall avoidance?
Solution(s):
If the given acceleration and deceleration time is too short, the output frequency of the inverter changes faster than the motor speed, and the inverter will stop working due to overcurrent, which is called stalling. In order to make the motor ...
|
|
Delta launched an integrated control solution for layer winding
As factories move from automation to intelligence, the requirements for equipment performance and scalability are progressing day by day. In response to the rapid development of electronic engineering, transportation and mechanical engineering and other occupations, in order to quickly manufacture related product parts and components, metal coil winding technology is also being carried out at a high speed.
|
|
How to wire the internal control and external control of Delta inverter
How to wire the internal control and external control of Delta's inverter?
Internal control: connect the main circuit power supply RST motor UVW, press the inverter panel to start and stop. Both the command source and the frequency frequency should be selected in the panel.
External ...
|
|
Solution to Delta's overload trip fault
1. The main reason for VFD overload
(1) Mechanical overload. The main characteristic of overload is the heating of the motor, which can be detected by reading the operating current on the display.
(2) The three-phase voltage imbalance leads to excessive running current in a certain phase, resulting in overload tripping. It is characterized by uneven heating of the motor ...
|
|
Inverter wiring and parameter setting method - Delta
The inverter used in industry is divided into two types: single-phase and three-phase, which is distinguished from the voltage supplied by the main circuit, which is the main circuit to be connected to RST three-phase 380 volt alternating current, and the output is connected to the UVW three-phase line to the motor; And the single-phase is the main circuit connected to the single-phase 220 volt LN alternating current, the output is the same ...
|
|
DC governor overhaul method - Delta
DC governor is a kind of motor speed regulation equipment, including motor DC governor, pulse width DC governor, thyristor DC governor, etc. Generally, it is a modular DC motor governor, which integrates power supply, control and drive circuits, selects three-dimensional structure layout, and selects micro-power consumption elements for control circuits.
|
|
Delta's key steps in inverter maintenance
First, the maintenance of the inverter must first check whether the sound in the operation of the motor is abnormal, including, whether the motor is in operation to form a sensation.
2. Check whether the natural environment of the inverter installation has changed. ...
|
|
Selection of braking resistors for Delta inverters
1. The necessity of braking resistance
If the regenerative energy that occurs during deceleration and descent in the application is too large, there is a possibility that the voltage of the main circuit inside the inverter will rise, causing damage.
Because usually the inverter has a built-in overvoltage maintenance function, the main circuit overvoltage (O...
|
|
The frequency of the inverter is given in a given way - Delta
The main way to use the inverter is to change the output frequency to achieve the controllability of the motor speed, so do you know what steps are required to complete the output frequency controllability? One of the main points is how to complete the change of the frequency signal supplied by the inverter equipment.
|
|
Delta's servo protection parameters are written
A3, B3 servo
P5-97 Motion Control Mobilization Commands
0x0003 Maintenance Activation (Successful Return 0x1003)
0x0004 Maintenance Waiver (Successful Return 0x1004)
If the wrong cipher code is entered, the error code Ennn will be sent back to exempt the loss, during which nnn indicates that there is a ...
|
|