With the development of electronic semiconductor information technology, technologies such as the Internet of Things, big data, and cloud channels are showing a trend of hundreds of schools of thought, which also drives the rapid development of intelligent production. Intelligent production also puts forward new requirements for controllers: high speed, large capacity, miniaturization, networking...... The functions of various controllers represented by programmable manipulators (PLCs) are gradually diversified and complex, so as to meet the requirements of intelligent, systematic and networked changes in modern production. Delta's AX3 series, a professional PLC-based motion controller equipped with CODESYS integrated development software channel, is a new generation of PLC products launched for future intelligent production based on Delta's years of experience in independent innovation and keen observation of shopping malls.
As a member of Delta's AX series clan using CODESYS channels, the AX3 series of PLC-based motion controllers have the same function as their brother AX8 series, with the same high-performance multi-center processor, built-in multiple communication ports and dedicated EtherCAT motion control network interfaces, and a command library for motion control specifications issued by international organizations, making them more suitable for simple machining equipment, electrical and electronic equipment, etc., on the basis of exquisite fuselage planning, testing equipment and other equipment are used automatically.
The AX3 is available in both standard and P2P versions up to 64 axes. In the case of Delta's first AX308E model, the CPU has 16 DIs and 8 DOs built-in, and the EtherCAT real-time communication feature allows the host to quickly respond to updates. Support 8-axis motion control, the minimum synchronization time can reach 1 ms; Built-in 2 sets of incremental encoders and 1 set of absolute encoders to ensure that the accuracy of motion control meets the needs; After the system is optimized by Delta, it can quickly identify the connection information of multiple brands of EtherCAT slaves, achieving a high degree of integration.
In the era of intelligent manufacturing, PLC should not only have excellent functions, but also serve as an important data node in the industrial Internet, so communication capabilities are often the central requirements of modern PLC. In addition to supporting EtherCAT, the AX3 series also has two built-in Gigabit LANs, which support Modbus, EtherNet/IP and OPC UA communication protocols, and can be connected to HMI, HDMI LCD screens, MES, ERP, SCADA and other host computer equipment, to meet the all-round needs of customers from a single machine to a whole automated production line, and can quickly meet the use of equipment automation transformation and promotion. In addition, it is equipped with USB ports, SD cards, high-speed digital I/O, ABS/INC encoders and other interfaces, which enrich the customer's construction configuration and improve the competitiveness of the equipment.
The AX3-series mainframes have chosen the new modification software DIADesigner+ as a project development tool. In addition, it supports the IEC61131 relevant motion function library, PLCopen MC specification function block and Delta's DMC function module, which can provide users with high execution power and convenience.
With the acceleration of the intelligent production process, users have very high requirements for the continuous promotion ability of the system. AX3 series supports all expansion modules (up to 32 units) of the high-performance general-purpose controller AS series, including various expansion modules such as digital I/O modules, analog modules, temperature modules, etc., as well as OPC-UA protocol, and can also be configured with DVP expansion through RTU-ECAT to build a more economical remote I/O.
With the successive promotion of the AX3 series, Delta's controllers used in the CODESYS channel have been further expanded, allowing users to have more choices in selecting Delta's motion controllers. Delta will also continue to enrich the composition of the AX3 family, and will launch various types of motion controllers in the future to promote the use of Delta in factory automation and mid-to-high-end OEM equipment. |
More on that
|
The impact of Delta's inrush current on the inverter
In the process of repairing the inverter, it is found that because of the back electromotive force in the stator winding, the electromotive force in the synchronous generator state and the self-induced electromotive force in the self-induced rotor, the current impact must have a negative impact on the motor, the inverter (Variable-frequency Drive, ...
|
|
Introduction of high-power fan inverter - Delta
High power means increased cost
The use of high-power fan inverter can indeed meet the various production needs of enterprises, but high-power also means an increase in production costs. Because the more power, the more power will be consumed. Assuming that a 20KW fan inverter can ...
|
|
Inverter maintenance and accessories should be replaced regularly – Delta inverters
1. Before the inverter is energized
The temperature and humidity of the surrounding environment should be detected first. Too high a temperature will cause the inverter to overheat the alarm. When severe, it will directly lead to damage to the power supply device of the inverter and short circuit of the circuit; Excessive humidity of the air can lead to a direct short circuit inside the inverter. When the inverter is in operation ...
|
|
Inverter selection point - Delta
1. When selecting the inverter, select the inverter with the appropriate control method according to the load characteristics
In addition to the inverter manufacturing process, it is also important to use the inverter's control method. The control methods of the inverter are mainly divided into two types: open-loop control and closed-loop control. In the meantime, the open-loop control method ...
|
|
Identify the problem area of the inverter - Delta
In the process of inverter protection and maintenance, various problems are often encountered, such as field line problems, poor primary parameter settings or mechanical equipment shortcomings. If there is a defect in the inverter, how to distinguish which part of the problem is a little more detailed here.
...
|
|
Delta's inverter speed regulation application site
Inverter is a kind of speed regulating device, where to use the motor speed regulation, especially asynchronous motor speed regulation, will use the inverter, now mainly in industrial equipment has been used on a large scale, because the motor is the heart of the industry, and the three-phase asynchronous motor occupies the vast majority of the share, ...
|
|
How the components of the inverter work – Delta
1. Inverter element - rectifier
Since it is difficult to change the frequency of the communication sine wave in the form of communication, the first operation of the inverter is to convert the waveform into direct current. To make it look like an AC, it is relatively easy to operate the DC. The most important component of all inverters is a ...
|
|
Synchronous control parameter setting method for two or more inverters - Delta
Step 1
Two inverters, two wires, and one power supply.
Step 2
The inverter wiring defines the two inverters as a master and a slave respectively, the host port 485A is connected to the slave port 485A, and the host port 485B is connected to the slave port 485B.
...
|
|
The case of Delta's multi-axis motion controller
The non-standard manipulator can be customized according to the practical needs of customers, because the non-standard manipulator has no specifications to follow, and there is no such kinematic model in the controller, so the development of the control system is difficult. Delta recently provided non-standard manipulators for pharmaceutical board manufacturers to supply control solutions ...
|
|
Delta's touch screen controls the inverter method
1. The touch screen is controlled by PLC inverter
1. Now the general control of the inverter needs to use PLC to communicate with the inverter, read the information of the inverter, and then the touch screen communicates with the PLC in order to complete the control of the inverter to start, stop, and monitor the operation of the inverter.
|
|
Correct use of Delta inverter in operation
(1) When the speed of the motor is controlled by the Delta inverter, the noise and temperature rise of the motor are higher than that of the frequency of the motor. When the motor is running at low speed, because the speed of the motor blades is low, the temperature rise of the motor becomes high.
|
|
A brief description of the selection of Delta inverters
Delta's inverter series are as follows:
1:VFD-EL,VFD-S,VFD-L,VFD-C200
Voltage 220V, 380V, power scale 100W-7.5kw
The above series are Delta's simple inverters, commonly known as economical inverters, which are used for small fan pumps, food and medical ...
|
|
Selection of inverter box structure - Delta
The box structure of the inverter should be adapted to the environmental conditions, that is, the temperature, humidity, dust, pH, corrosive gas and other elements must be considered. There are several common types of structures that users can choose from:
1) Open IPOO ...
|
|
Delta's inverter failure analysis
1. Fault code:
SE1 parameter replication error
Fault Description:
Keypad replication function error correct
Solution:
Keypad replication action errors, including communication delays, communication errors (Keypad received FF86 errors), and parameter value errors
...
|
|
The impact of grid quality on the life of the inverter – Delta
Inverter is a high-tech product, mainly composed of power electronic equipment and microelectronic equipment. The three-phase communication grid is connected to the input of the frequency converter. The input end of the inverter is a rectifier circuit, and the output end is a frequency conversion circuit. As a result, the voltages and currents on the input and output sides include abundant ...
|
|
Introduction to the features of Delta's power modules
1) Brief planning. Only one battery module, paired with several discrete components, is able to obtain a battery.
2) Shorten the development cycle. It is generally equipped with a variety of input, output, and battery module options. Users are also able to repeat or cross-stack, combined with modular batteries, to complete multi-channel ...
|
|
Precautions for the use of Delta inverters
1. The inverter must be selected correctly.
2. Read the product manual carefully, and wiring, device and application in accordance with the requirements of the manual.
3. The inverter device should be firmly grounded to suppress radio frequency disturbance and avoid electric shock caused by leakage of the inverter.
4、 ...
|
|
Selection of Delta power supply
There are many models of Delta's power supplies, and the currents and functions supported are also different, so how to choose?
VX Series Power Supplies.
VX270: Active PFC270w, but 12v is still small and can only be used at low power.
Active PFC and 12v output up to 276w at 300...
|
|
Precautions for the installation environment of the inverter - Delta inverter
(1) Ambient temperature:
The inverter is the same as other electronic equipment, and has certain requirements for the ambient temperature, which is generally "-10-+40°C". Because the inverter is a high-power electronic equipment, it is easy to be affected by the operating temperature, but in order to ensure the safety of the inverter...
|
|
Inverter performance test method - Delta
As we all know, the inverter has many maintenance functions, such as overcurrent, overvoltage, overload maintenance and so on. With the continuous improvement of industrial automation, frequency converters have also been widely used. This article will explain to you how to use a multimeter to measure the quality of the inverter.
Need...
|
|