Buke servo motor - wiring connection of servo motor encoder
(1) Wiring should be done with the power supply OFF, and if the output line is in contact with the power supply when the power is turned on, the output circuit may be damaged.
(2) If the wiring is incorrect, the internal circuit may be damaged, so pay full attention to the polarity of the power supply when wiring.
(3) If and high-voltage lines, ...
|
|
A picture to understand the Internet of Things and interactive functions of the HMI touch screen
In the past industrial field, HMI touch screens were used more as a window for people to interact with mechanical equipment, and were used to connect various PLCs and sensors. Nowadays, in the context of the Industrial Internet of Things, manufacturing enterprises need to integrate OT and IT technologies more to achieve their own digital and intelligent transformation.
|
|
Buke launched the MK series enhanced 4.3-inch all-in-one computer
Buke MK series all-in-one machine on the market for more than a year, received unanimous praise from many customers, in the Buke "quality first" to create an end-to-end full life cycle product quality management system" and "demand management" under the internal and external drive, through the application feedback of this series of products and in order to fit more ...
|
|
How to zero the encoder of Buke motor?
1. Remove the motor encoder, power on the system, and power on the driver
2. Set the drive password to 510 and the No. 4 parameter to 4 (encoder zeroing mode)
3. Switch the driver to the encoder zero mode CO-press the confirm key to enter the CO-rdy ...
|
|
Buke touch screen unresponsive maintenance method
1. Touch screen maintenance, touch no response fault phenomenon:
When touching the screen, the mouse arrows do not move, and the position does not change.
Second, the cause of the failure of touch screen maintenance touch non-response:
(1) On the surface of the acoustic wave touch screen, the sound wave reflection stripes on the four perimeters ...
|
|
Buke touch screen - daily maintenance and main matters of touch screen
Daily maintenance of the touch screen:
1. The capacitive touch screen should generally be filmed, and it should be pasted well. membranes (double-layer membranes) that meet ESD standards;
2. The capacitive touch screen is cleaned regularly, and the liquid crystal cleaning solution used for the computer is used (alcohol and furniture cleaning liquid cannot be used);
3. Transport...
|
|
Buke servo motor - servo motor maintenance needs to pay attention to
1. Check the servo motor to ensure that there is no fatal damage outside;
2. Check the fixed parts of the servo motor to ensure that the connection is strong;
3. Check the output shaft of the servo motor to ensure the rotation and circulation;
4. Check the encoder connection line of the servo motor and the ...
|
|
Buke servo motor - what are the basic applications of AC servo motor?
Material metering
The measurement of powdery materials is commonly used in the way of screw measurement. The purpose of measurement is achieved by the number of turns of the screw rotation. In order to improve the accuracy of measurement, the speed of the screw is required to be adjustable, and the position positioning is accurate.
|
|
The causes and solutions of the shutdown of the Buke motor due to pollution
Reasons for the shutdown of the speed up Buke motor due to contamination:
1. Bearing lubrication failure or bearing surface damage
Contaminants can disrupt bearing lubrication and damage bearing surfaces. This will cause the friction to generate heat. If the problem cannot be solved, the increased heat may cause the bearing and the ...
|
|
Common fault causes and solutions for Buke servo motor maintenance
1. The motor cannot rotate after being energized, but there is no abnormal noise, no peculiar smell and smoke
(1) The cause of the failure
(1) The power supply is not connected (at least two phases are not connected);
(2) Fuse blowing (at least two-phase blowing);
(3) The overcurrent relay is adjusted too small;
(4) The wiring error of the control equipment ...
|
|
Buke servo motor - the regular maintenance content of AC motor
1. Wipe the motor. Remove the dust and sludge on the outside of the motor base in time. If there is a lot of dust in the environment, it is best to clean it once a day.
2. Check and wipe the motor terminals. Check whether the junction box wiring screws are loose or burned.
3. Check the screws of each fixed part ...
|
|
Buke servo motor - common faults and solutions of servo motor encoders
1. Encoder connection line failure: This kind of failure has the highest probability and is often encountered in maintenance, so it should be a priority factor. Often, encoder cables are open, short, or in poor contact, so the cable or connector needs to be replaced. Special attention should also be paid to whether the cable is loose and causes open soldering or ...
|
|
Buke servo drive - the wiring method of the stepper driver and PLC
1. First of all, the first step is to power the 24V power supply: brown positive blue negative yellow and green wire.
2. Then it is necessary to connect the two sets of wires of the motor to the A+ A-, B+ B- of the driver.
3. Then connect the 24v power supply-v to the GND of the driver.
4. And then ...
|
|
Buke servo motor - how to correctly select the servo motor
1. Calculate the load inertia and the matching of inertia, and the inertia matching of some products can reach 50 times, but in fact, the smaller the better, so that the accuracy and response speed are good.
2. Conversion of load torque on motor shaft and calculation of acceleration and deceleration torque.
3. Rotation speed and encoder resolution ...
|
|
Common faults and maintenance methods of Buke touch screen
1. Surface acoustic touch screen.
(1) Fault 1: Touch deviation
Symptom 1: The position of the finger does not coincide with the mouse arrow.
Reason 1: After installing the driver, there is no vertical touch of the bullseye center position when the position is corrected.
Solution 1: Recalibrate ...
|
|
Classification and characteristics of the human-machine interface of Buke
MT4000 series
MT4000 series HMI is a sub-series of eView HMI, which is one of Buke's HMI products
Series, human-machine interface MT4000 is referred to as ordinary application series. MT4000 series HMI products adopt 32 ...
|
|
Buke servo motor - AC servo motor maintenance method
1. Please ensure that the environment is clean and avoid oil. When used in dusty and humid places, although the protection level of the servo motor is very high, it will be easy to cause problems if it is often used in such an environment.
2. Regularly check the use of the servo motor to see if there is any damage outside.
|
|
Buke servo motor - AC servo motor vibration fault analysis
Mechanical
1. Bearing
The bearing clearance on the lead screw housing is too large after wear, or the bearing roller elements and cages are severely worn due to the lack of grease in the bearing, resulting in excessive loads. After bearing wear, the clearance is too large, which will cause the coaxiality error between the center of the motor rotor and the center of the lead screw.
|
|
What are the characteristics of Buke servo motor - AC gear reducer?
1. AC motors are cheaper to manufacture.
2. With the development of vector frequency conversion technology, it has been possible to simulate direct current with frequency conversion motors
3. Compared with DC motor, it has enough advantages in simple structure, easy maintenance, low environmental requirements, energy saving and improved productivity.
|
|
How to solve the problem that the touch screen of Buke does not respond?
1. Check whether the joints of each connecting line are loose;
2. Check whether there is a conflict between the serial port and the abort number, and if there is a conflict, the resources should be adjusted to circumvent the conflict. Then check whether there are gaps in the surface layer of the human-machine interface, and if there are gaps, they should be replaced immediately. It also needs to be inspected ...
|