1. Check whether the joints of each connecting line are loose;
2. Check whether there is a conflict between the serial port and the abort number, and if there is a conflict, the resources should be adjusted to circumvent the conflict. Then check whether there are gaps in the surface layer of the human-machine interface, and if there are gaps, they should be replaced immediately. It is also necessary to check whether there is dust on the surface layer of the human-machine interface, and if so, use a thin cloth to eliminate it. Check whether the display light on the control box is working normally, if it is normal, the display light is green and flashing;
3. If everything is normal in the upper part, you can replace the man-machine interface by replacing the control box, then replacing the touch display, and then replacing the main chassis.
|
More on that
|
Buke servo motor - the starting method of single-phase AC motor
The first type, the split-phase starting type, as shown in Figure 1, is assisted by an auxiliary starting winding, and its starting torque is not large. The operating rate remains roughly constant. It is mainly used in electric fans, air conditioning fans, motors, washing machines and other motors.
Second, when the motor is stationary, the centrifugal switch is connected to the ...
|
|
Buke touch screen unresponsive maintenance method
1. Touch screen maintenance, touch no response fault phenomenon:
When touching the screen, the mouse arrows do not move, and the position does not change.
Second, the cause of the failure of touch screen maintenance touch non-response:
(1) On the surface of the acoustic wave touch screen, the sound wave reflection stripes on the four perimeters ...
|
|
A picture to understand the Internet of Things and interactive functions of the HMI touch screen
In the past industrial field, HMI touch screens were used more as a window for people to interact with mechanical equipment, and were used to connect various PLCs and sensors. Nowadays, in the context of the Industrial Internet of Things, manufacturing enterprises need to integrate OT and IT technologies more to achieve their own digital and intelligent transformation.
|
|
Buke servo motor - common fault causes and maintenance methods of servo motor encoders
1. Start the servo motor before work
(1) Measure the insulation resistance (0.5M or more for low-voltage motors).
(2) Measure the power supply voltage, check whether the wiring of the motor is correct, and whether the power supply voltage meets the requirements.
(3) Check whether the starting device is normal.
( ...
|
|
Buke servo motor - six common faults and treatment methods of servo motors
1. The motor temperature is too high or the smoke is faulty
Cause:
1. Excessive load
2. Two-phase operation
3. Air duct blockage
4. The ambient temperature increases
5. Stator windings are short-circuited between phases or turns
6. Stator winding grounding
7. The power supply voltage is too high ...
|
|
Buke servo motor - servo drive fault and treatment method
1. When the motor rotates, the LED light flashes
(1) Cause of failure: HALL phase error. Solution: Check whether the motor phase setting switch is correct
(2) Fault cause: HALL sensor failure, treatment method: When the motor rotates, detect the voltage of HalA, HalB, HalC ...
|
|
The causes and solutions of the shutdown of the Buke motor due to pollution
Reasons for the shutdown of the speed up Buke motor due to contamination:
1. Bearing lubrication failure or bearing surface damage
Contaminants can disrupt bearing lubrication and damage bearing surfaces. This will cause the friction to generate heat. If the problem cannot be solved, the increased heat may cause the bearing and the ...
|
|
Buke launched the MK series enhanced 4.3-inch all-in-one computer
Buke MK series all-in-one machine on the market for more than a year, received unanimous praise from many customers, in the Buke "quality first" to create an end-to-end full life cycle product quality management system" and "demand management" under the internal and external drive, through the application feedback of this series of products and in order to fit more ...
|
|
Buke servo motor - three control modes of servo motor and detailed introduction
In terms of the response speed of the servo drive: the torque mode has the smallest amount of calculation, and the driver responds the fastest to the control signal; The position mode is the most computationally intensive, and the driver is the slowest to respond to the control signal.
When there are relatively high requirements for dynamic performance in motion, it is necessary to ...
|
|
Buke servo motor - servo motor maintenance needs to pay attention to
1. Check the servo motor to ensure that there is no fatal damage outside;
2. Check the fixed parts of the servo motor to ensure that the connection is strong;
3. Check the output shaft of the servo motor to ensure the rotation and circulation;
4. Check the encoder connection line of the servo motor and the ...
|
|
The reason for the maintenance failure of the Buke servo motor that is shut down due to pollution
1. Bearing lubrication failure or bearing surface damage
Contaminants can disrupt bearing lubrication and damage bearing surfaces. This will cause the friction to generate heat. If the problem cannot be solved, the increased heat may cause a catastrophic failure of the bearing and the Buke motor to stop running.
2、 ...
|
|
Buke touch screen - the classification of touch screen and its characteristics introduction
1. Resistive touch screen
The most important part of a resistive touchscreen is a resistive thin-film screen that matches the surface of the display very well. This is a multi-layer composite film based on a layer of glass or hard plastic plate, coated with a transparent metal oxide (ITO indium oxide, transparent conductive ...
|
|
Buke servo motor - how to choose the model of servo motor?
1. The power of the motor
2. The power supply voltage of the motor
3. The encoder type of the motor
4. The size of the base of the motor
5. The movement mode of the motor
6. Motor communication bus
7. Whether the motor is equipped with a brake mechanism
8. Motor driver class ...
|
|
Buke touch screen - touch screen touch no response fault causes and treatment methods
Cause of the failure
1) The sound wave reflection stripes on the four periphery of the surface sound wave touch screen are seriously dusty or scale, resulting in the touch screen not working.
2) The touch screen is malfunctioning.
3) The touch screen control card is faulty.
4) The touch screen signal line is faulty ...
|
|
Buke servo motor - the setting of common parameters of servo drive
(1) Azimuth share gain
Sets the share gain of the azimuth ring adjuster. The higher the set value, the higher the gain, the greater the stiffness, and the smaller the azimuth lag under the same frequency command pulse. However, too large a value may cause vibration or overshoot. The parameter values are determined by the detailed servo ...
|
|
What are the characteristics of Buke servo motor - AC gear reducer?
1. AC motors are cheaper to manufacture.
2. With the development of vector frequency conversion technology, it has been possible to simulate direct current with frequency conversion motors
3. Compared with DC motor, it has enough advantages in simple structure, easy maintenance, low environmental requirements, energy saving and improved productivity.
|
|
The solution of the alarm code 08 when the servo drive is accelerated
1. Please check the motor power line to confirm whether there is a short circuit in the phase wire of the motor
2. If there is no short circuit in the phase line of the motor, it is determined that the internal power tube problem of the driver is determined
|
|
Buke human-machine interface - anti-interference countermeasures of PLC controller and human-machine interface
1. Adopt a power supply with excellent performance to suppress the interference introduced by the power grid.
For the power supply supplied by the PLC controller, the non-power line power supply should be adopted, and the special line power supply should be used directly from the main bus of the low-voltage distribution room. Isolation transformers are selected, and the transformer capacity should be larger than the actual needs.
|
|
Buke motor - stepper servo drive as soon as it moves, what is the reason for the alarm
First, the common causes of such faults caused by mechanical oscillation (acceleration/deceleration) when the motor is powered on are:
(1) The pulse encoder is faulty. At this time, the servo system should be checked to see if it is stable, whether the circuit board maintenance detection current is stable, and at the same time, the electrical ...
|
|
The kick-off meeting of the organizational reform project of Buke Co., Ltd. was a complete success!
On December 17, Buke Co., Ltd. and Willis Towers Watson (formerly Torrei Watson, the world's leading professional services company) held the "Buke Co., Ltd. Organizational Reform and Upgrade Project Kick-off Meeting". Xu Changliang, Chief Consultant of Willis Towers Watson, Sheng Shaoqin, Partner of Willis Towers Watson, Tang Dong, Chairman of Buke Group, Bu...
|
|