Electromagnetic interference caused by the working principle - LS power inverter

Create Date: 2024-8-30 12:03:23|Source: LS/Power Generation

1. Harmonic disturbance

The rectifier circuit will produce harmonic current, which produces a voltage drop on the impedance of the power supply system, resulting in distortion of the voltage wave pattern, and the voltage of this distortion constitutes a disturbance on many appearances, and the common voltage distortion is the flattening of the top of the sine wave. When the harmonic current is constant, the voltage distortion becomes more serious in the case of a weak power supply, and the characteristic of this disturbance is that it will cause disturbance to the equipment that uses the same power grid, and has nothing to do with the separation between the equipment and the inverter.

                               Electromagnetic interference caused by the working principle - LS power inverter

2. Radio frequency conduction emission disturbance

Because the load voltage is pulse-shaped, the current drawn by the inverter from the power grid is also pulse-shaped, and this pulse current contains a large number of high-frequency components, constituting radio frequency disturbance, which is characterized by the disturbance that will cause disturbance to the appearance of the same power grid, and has nothing to do with the interval between the appearance and the inverter.

3. Radio frequency radiation disturbance

RF radiation disturbs the input and output cables from the LS inverter. When there is a radio frequency disturbance current on the input and output cables of the inverter, because the cable is equivalent to an antenna, electromagnetic wave radiation will inevitably be generated, resulting in radiation disturbance. The PWM voltage transmitted on the output cable of the inverter also contains abundant high-frequency components, which will generate electromagnetic wave radiation and constitute radiation disturbance. Radiated disturbance is characterized by the fact that when other electronic devices approach the inverter, the disturbance becomes severe.

More on that
How LS produces power PLC operation How LS produces power PLC operation

Although many relays, timers and counters are often used in the ladder diagram programs used by LS PLC, LS PLC does not have these hardware physically, but uses memory and program programming methods to make logic control modifications, and connects external machines through output components.

What is the difference between LS inverter and LG inverter? What is the difference between LS inverter and LG inverter?

LS inverter and LG inverter are the same, there is no difference between the two. LS inverter, the full name of LS AC inverter governor, after supplying a variety of configurations, converts direct current into communication power, and changes the general power supply ...

Asynchronous motor with inverter - LS generates electricity Asynchronous motor with inverter - LS generates electricity

Before the asynchronous motor is equipped with an inverter, let's take a look at the three major types of mechanical equipment loads: 1. Constant torque load: such as conveyor belts and mixers; When the inverter drags a load of constant torque nature, the torque at low speed should be large enough and the overload capacity should be large enough. If you need ...

Inverter maintenance principle analysis and inspection method Inverter maintenance principle analysis and inspection method

Principle analysis is the most fundamental way to eliminate the problem, when other methods are difficult to see the effect, you can start from the basic principle of the circuit, step by step to view, and finally find out the cause of the problem. To use this method, it is necessary to have a clear understanding of the principle of the circuit, and to grasp the various ...

LS automatic gain adjustment for power generation LS automatic gain adjustment for power generation

In fact, there are also options for automatic gain adjustment, which generally divide the control response into several levels, such as high echo, medium echo, and low echo, which can be set by the user according to actual needs. Azimuth Share Buff: 1. Set the share gain of the azimuth ring adjuster; 2 ...

Introduction to the design of inverter control cabinet - LS power production Introduction to the design of inverter control cabinet - LS power production

The inverter should be installed inside the control cabinet, and the following problems should be paid attention to when planning the control cabinet: 1) Heat dissipation issues: The heating of the inverter is caused by internal losses. In the inverter, the main circuit is the main circuit for the loss of each part, accounting for about 98%, and the control circuit accounts for 2%. ...

The difference between low-speed and high-speed centrifuges – LS generates electricity The difference between low-speed and high-speed centrifuges – LS generates electricity

Through the rational planning of the structure of the low-speed centrifuge, the hygienic dead angle can be effectively eliminated. The transition of the structural parts is smooth, and the surface is polished. External structural components, fasteners, and rollers are made of stainless steel. The housing is a clamshell type, which allows for thorough cleaning of the interlayer space of the centrifuge housing without the need for a bowl ...

Precautions for the coordination of inverter and PLC - LS produces electricity Precautions for the coordination of inverter and PLC - LS produces electricity

As an alternative to traditional relays, PLC is widely used in various fields of industrial control. Because the PLC can be used to change the control process with software, and has the characteristics of small size, sensitive assembly, simple programming, strong anti-disturbance ability and high reliability, it is especially suitable for operation in harsh environments. ...

LS electric braking unit functions, advantages and operation process LS electric braking unit functions, advantages and operation process

First, the main function of the braking unit In some applications, the need for rapid speed reduction, according to the principle of asynchronous motor, it can be known that if the slip is larger, the greater the torque, the same braking torque will increase with the increase of the speed reduction rate, so that the system speed reduction time is greatly shortened, and the energy feedback is greatly ...

The internal accessories component of the power production circuit breaker The internal accessories component of the power production circuit breaker

1. Auxiliary contact: the contact mechanically linked with the main circuit of the circuit breaker and the closing mechanism is mainly used for the display of the circuit breaker and the closing status, and is connected to the control circuit of the circuit breaker through the opening and closing of the circuit breaker to control or interlock its related electrical appliances. For example, output to signal lights, relays, etc.

LS Electric has been selected as one of the "Top 100 Global Innovators" for 10 consecutive years. LS Electric has been selected as one of the "Top 100 Global Innovators" for 10 consecutive years.

In Clarivate's recent statement, LS Electric was named one of the top 100 innovators in the world. The trophy handover ceremony was held in Anyang, LS Electric R&D Park, with Kim Yeong-geun, Chief Technical Officer of LS Electric, and Ahn Seong-sik, CEO of Clarivate Korea, acting as representatives of both parties.

Precautions for the selection of peripheral equipment for LS power inverter Precautions for the selection of peripheral equipment for LS power inverter

The peripheral equipment of the inverter mainly includes cables, contactors, air switches, reactors, filters, braking resistors, etc. Whether the selection of the peripheral equipment of the inverter is correct and suitable also directly affects the normal operation of the inverter and the service life of the inverter.

Key points of LS power BKN circuit breaker design Key points of LS power BKN circuit breaker design

(1) The cooperation between the circuit breaker and the circuit breaker should consider the instantaneous trip device action value of the superior circuit breaker, which should be greater than the maximum expected short-circuit current at the outlet end of the lower circuit breaker.

How to troubleshoot the fault of the inverter - the power inverter How to troubleshoot the fault of the inverter - the power inverter

Because the application method is incorrect or the setting environment is unreasonable, the inverter will simply malfunction and cause problems, or the expected operation effect will not be satisfied. In order to prevent problems before they occur, it is important to carefully analyze the cause of the problem in advance. ...

The working principle of the LS power production module The working principle of the LS power production module

When the LS power generation module is put into operation, its working process is generally divided into three stages: input sampling, user program fulfillment, and output rewriting. The completion of these three phases is called a scan cycle. During the entire operation, the PLC's CPU repeatedly performs the upper ...

The application of the inverter to supply power to the motor has encountered a problem The application of the inverter to supply power to the motor has encountered a problem

A frequency converter is a device that converts power to other frequencies of power supply. The power frequency of our country is 50Hz, in the field of motors, in order to change the speed of the motor, or other performance changes, many motors choose inverter power supply. ...

What are the advantages of frequency conversion speed regulation - LS power production What are the advantages of frequency conversion speed regulation - LS power production

1. Outstanding frequency conversion speed regulation characteristics Completing the frequency conversion speed regulation of asynchronous motor is the "century wish" that people have been waiting for since the creation of asynchronous motor for 100 years. Through unremitting improvement, enhancement and perfection, the speed regulation function of VFD is not bad, that is, compared with the DC speed regulation system, the part ...

The working principle of LS PLC module The working principle of LS PLC module

When LS PLC is put into operation, its operation process is generally divided into three stages: input sampling, user program fulfillment and output rewriting. The completion of these three phases is called a scan cycle. During the entire operation, the PLC's CPU repeatedly performs the ...

Application of servo motor - LS power generation Application of servo motor - LS power generation

Quick to use: There are three cables necessary for the operation of the motor: power cable; Motor power line, motor encoder line. Control line interface X5: Servo enable necessary pin C24V power supply (7,41) Servo enable SR ...

Cycloidal reducer transmission system testing - LS power production Cycloidal reducer transmission system testing - LS power production

With the support of data processing, signal analysis and computer skills, the transmission system uses dynamic error detection equipment, starting from the measurement of time domain error information, and the internal dynamic test of the transmission system should include the following aspects. ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top