Through the rational planning of the structure of the low-speed centrifuge, the hygienic dead angle can be effectively eliminated. The transition of the structural parts is smooth, and the surface is polished. External structural components, fasteners, and rollers are made of stainless steel. The clamshell is a clamshell that allows for thorough cleaning of the interlayer space of the centrifuge housing without the need for a bowl. It can be started with an inverter, which is stable and stable, and the separation factor is adjustable; non-touch energy braking system; Anti-static belt drive; fuselage closed structure; The seals are made of silicone rubber or fluoroelastomer. It can meet the requirements of airtight explosion-proof, and is suitable for toxic, flammable and explosive occasions.
A high-speed centrifuge is a machine that uses centrifugal force to separate components from liquid and solid particles or mixtures of liquids and liquids. Centrifuges are primarily used to separate solid particles and liquids from suspensions; or separating two non-solutions with different densities in the emulsion (e.g., separating cream from milk); It can also be used to remove liquids from wet solids, such as drying wet clothes in a washing machine; The special overspeed tube separator also separates gas mixtures with different densities; Some sedimentation centrifuges can also classify solid particles according to their density or particle size, using different densities or different particle sizes to settle at different rates in liquids.
|
More on that
|
Selection of AC contactors in the field of building electrical - LS power production
1. The series and parallel connection application of contactors Many electrical equipment are single-phase loads, so several poles of multi-pole contactors can be used in parallel. Such as resistance furnaces, welding transformers, etc. When using several poles in parallel, a smaller capacity contactor can be used. However, it must be noted that after parallel ...
|
|
LS power inverter function
1. Soft up
The direct launch of the inverter motor has a serious impact on the power grid, and it will also have too high requirements for the capacity of the power grid, which is extremely unfavorable to the service life of equipment and power grid circuits. After the use of inverter to save energy, the use of inverter's speed regulation (V/F) function will make the starting current from a small ...
|
|
Energy-saving method of ventilator inverter - LS power generation
high-power
Although some inverters are fan type inverters, but it is a low-power fan inverter, such an inverter does not have the effect of energy saving, and it is necessary to achieve energy saving must be a high-power inverter, in addition to the high-power fan inverter, it is necessary to meet its ...
|
|
The power frequency motor is abnormally installed with an inverter - LS produces electricity
Installing a variable-frequency drive (VFD) on the power frequency motor can complete the accurate control and speed regulation of the motor, and improve the power and accuracy of the forward motor. However, if not properly equipped and used, it may cause the following hazards:
...
|
|
Introduction of LS PLC programming software
LS PLC programming software is a professional PLC programming assistant tool, providing excellent interface, which can carry out PLC programming operations such as online modification, debugging and self-diagnosis, packing and debugging, etc., compatible with LG Master-K series and LG MASTER-K series, which can make you in the process of processing in a timely manner.
|
|
After the contactor is energized, the start button continuously engages and disconnects ?—— LS generates power
What is the reason why the contactor keeps engaging and disconnecting by pressing the start button after the AC contactor is energized?
In my personal opinion, most of the situation is caused by the wrong coil voltage of the replacement AC contactor, or the purchase of ...
|
|
How to operate LS inverters
1. When the power supply is now powered or the inverter is in running condition, do not open the shell of the inverter. Otherwise, an electric shock may occur.
2. When the front cover of the inverter is opened, do not move the inverter. Otherwise, you may be shocked by the high-voltage terminals or exposed charging capacitors. ...
|
|
Inverter carrier frequency adjustment method - LS power generation
A. The output voltage of the SPWM inverter is a series of pulses, and the pulse frequency is equal to the carrier frequency.
B. In the current of the motor, there is a harmonic component with a strong carrier frequency, which will cause the vibration of the motor core and announce the noise. If the frequency of the noise is the same as that of the motor core.
|
|
Six misunderstandings in the installation and use of inverters - electricity production
Myth 1: Connect electromagnetic switches and electromagnetic touches in the output circuit of the inverter
In practical application, some occasions need to use the touch device for frequency converter switching: such as switching to the power frequency state when the frequency conversion is faulty, or the election is used to drag two methods, a motor is faulty, and the variable frequency is used.
|
|
Why can't the inverter be equipped with a leakage protector?
When using an inverter, a leakage maintainer must not be used. This is a major criterion for the use of frequency converters.
Some users choose the corresponding leakage maintainer for the inverter when using the inverter. *The result is: the inverter moves together ...
|
|
Inverter maintenance principle analysis and inspection method
Principle analysis is the most fundamental way to eliminate the problem, when other methods are difficult to see the effect, you can start from the basic principle of the circuit, step by step to view, and finally find out the cause of the problem. To use this method, it is necessary to have a clear understanding of the principle of the circuit, and to grasp the various ...
|
|
The reason why the inverter cannot be equipped with a leakage protector
When using inverters, leakage protectors must not be used. This is a major principle of the use of frequency converters.
Some users choose the corresponding leakage protector for the inverter when using the inverter. *The result is: the inverter moves together, the leakage protector acts, and the system can't ...
|
|
LS power production contactor selection
How LS Contactor Works:
Generally, after the contactor coil is energized, the entire coil current will generate a magnetic field, which will make the core inside have electromagnetic attraction to attract the core, and let their communication contactor point action normally closed contact disconnect, or close, which ...
|
|
The method of judging the quality of components - LS power production
1. Detection of ordinary diodes
Use the MF47 multimeter to measure, connect the red and black watch pens to the two ends of the diode, read the reading, and then adjust the watch pen to measure. According to the results of two measurements, the forward resistance value of the general low-power germanium diode is 300-500Ω, and the silicon diode ...
|
|
How to select the inverter motor - LS produces electricity
Frequency conversion speed regulation motor is generally selected 4-level motor, the fundamental frequency operation point is designed at 50Hz, the frequency of 0-50Hz (speed 0-1480r/min) scale of the motor for constant torque operation, frequency 50-100Hz (speed 1480-2800r/min) scale of the motor for constant power operation, the entire speed regulation scale of (0 ...
|
|
The difference between overload and overcurrent of the inverter
(1) The maintenance objectives are different
Overcurrent is mainly used to maintain the inverter, whereas overload is mainly used to maintain the motor. Because the capacity of the inverter sometimes needs to be increased by one or even two gears than the capacity of the motor, in this case, the inverter is not necessarily overcurrent when the motor is overloaded.
...
|
|
The inverter generates electricity through the principle of intermediate DC bus power supply - LS
Most of the inverter manufacturers produce traditional inverters, and their control systems and other power supplies are directly provided by single-phase or three-phase power grids. However, due to the increasing use of VFDs and servo motor amplifiers, a new power supply may emerge: powered by the central DC bus of the VFD. This electric ...
|
|
LS inverter classification
LS Denden's low-voltage inverters provide optimal speed control in a variety of industrial sites, and are solutions that can demonstrate the completion of an automation system and have an epoch-making power saving effect. It includes four types of products: IGXA; S100; IS7; C100 series.
...
|
|
The main part of LS power inverter is composed
The inverter circuit is the first part of the inverter
The function of the DC central circuit is to smooth the output of the rectifier circuit to ensure that the inverter circuit and the control power supply can obtain a DC power supply with higher quality. When the rectifier circuit is the voltage flow of the central circuit, the primary component is the electrolysis of Darongtong ...
|
|
LS Electric has been selected as one of the "Top 100 Global Innovators" for 10 consecutive years.
In Clarivate's recent statement, LS Electric was named one of the top 100 innovators in the world. The trophy handover ceremony was held in Anyang, LS Electric R&D Park, with Kim Yeong-geun, Chief Technical Officer of LS Electric, and Ahn Seong-sik, CEO of Clarivate Korea, acting as representatives of both parties.
|
|