How to troubleshoot the fault of the inverter - the power inverter

Create Date: 2024-8-30 12:03:23|Source: LS/Power Generation

Because the application method is incorrect or the setting environment is unreasonable, the inverter will simply malfunction and cause problems, or the expected operation effect will not be satisfied. In order to prevent problems before they occur, it is important to carefully analyze the cause of the problem in advance.

                                     How to troubleshoot the fault of the inverter - the power inverter

1. How to check the inverter fault

Usually, the LED will display a problem code after the inverter outlet problem, and the information indicated by the problem code of each inverter is not the same, and the corresponding inverter manual needs to be checked. It will be very convenient to query the problem code online, and the fault information of the mainstream inverter on the market can be found through the system, and the WeChat public account "look at the industry" is attached to the WeChat public account, and the fault code of the inverter can be directly entered, and the corresponding problem information can be seen, and this function is free to use.

2. External electromagnetic induction disturbance

If there are disturbance sources around the inverter, they will invade the inverter through radiation or power lines, causing the misoperation of the control loop, resulting in abnormal operation or shutdown, and even damage to the inverter in severe cases. It is important to improve the anti-disturbance ability of the inverter itself, but because of the constraints of equipment cost, it is more reasonable and necessary to adopt the noise control method externally to eliminate the disturbance source. The following methods are specific methods to implement the "three noes" principle of noise disturbance: all relays around the inverter, the control coil of the contactor needs to be installed to avoid impulse voltage absorption equipment, such as RC absorber; Minimize the wiring interval of the control loop and separate it from the main circuit; The designated selection of shielded wire circuit shall be carried out according to the rules, and if the line is longer, a reasonable relay method shall be selected; The inverter grounding terminal should be carried out according to the rules, and should not be mixed with electric welding and power grounding; The input of the inverter is equipped with a noise filter to avoid disturbance from the power supply inlet.

3. Device environment

Inverters are electronic equipment and equipment, and there are detailed requirements for the equipment operation environment in their specifications. Under special circumstances, if these requirements cannot be satisfied, it is necessary to try to choose the corresponding pressing methods: oscillation is the main cause of mechanical damage to electronic equipment, and rubber and other vibration isolation methods should be used for occasions with large oscillation impact; Moisture, corrosive gases and dust will form electronic equipment rust, poor contact, insulation decline and short circuit, as a precautionary measure, the control board should be treated with anti-corrosion and dust-proof, and the closed structure should be selected; Temperature is an important factor affecting the life and reliability of electronic equipment, especially semiconductor equipment, air conditioning should be installed according to the environmental conditions required by the equipment or avoid direct sunlight.

In addition to the above three points, it is also necessary to regularly check the air filter and cooling fan of the inverter. For special cold occasions, in order to avoid the microprocessor from operating normally due to low temperature, necessary measures such as setting up space heaters should be adopted.

More on that
Elements of LS power inverter operation Elements of LS power inverter operation

1. Physical environment (1) Temperature factor Temperature has a huge impact on the lifetime and reliability of the electronic components inside the inverter. When using the inverter in a high operating temperature environment, it is necessary to take additional cooling measures to ensure that the ambient temperature is stable in the inverter.

Precautions for the selection of peripheral equipment for LS power inverter Precautions for the selection of peripheral equipment for LS power inverter

The peripheral equipment of the inverter mainly includes cables, contactors, air switches, reactors, filters, braking resistors, etc. Whether the selection of the peripheral equipment of the inverter is correct and suitable also directly affects the normal operation of the inverter and the service life of the inverter.

Inverter carrier frequency adjustment method - LS power generation Inverter carrier frequency adjustment method - LS power generation

A. The output voltage of the SPWM inverter is a series of pulses, and the pulse frequency is equal to the carrier frequency. B. In the current of the motor, there is a harmonic component with a strong carrier frequency, which will cause the vibration of the motor core and announce the noise. If the frequency of the noise is the same as that of the motor core.

The main part of LS power inverter is composed The main part of LS power inverter is composed

The inverter circuit is the first part of the inverter The function of the DC central circuit is to smooth the output of the rectifier circuit to ensure that the inverter circuit and the control power supply can obtain a DC power supply with higher quality. When the rectifier circuit is the voltage flow of the central circuit, the primary component is the electrolysis of Darongtong ...

Wiring method of the main circuit of the inverter - LS power generation Wiring method of the main circuit of the inverter - LS power generation

1. The power supply should be connected to the R, S, and T terminals of the VFD, and should not be connected to the VFD (U, V, W), otherwise the VFD will be damaged. It is necessary to clean up the trivial parts of the wire head after wiring, which may lead to abnormalities, failures, and failures, and it is necessary for the VFD to always be clean. When punching holes in the console, note that ...

Selection of AC contactors in the field of building electrical - LS power production Selection of AC contactors in the field of building electrical - LS power production

1. The series and parallel connection application of contactors Many electrical equipment are single-phase loads, so several poles of multi-pole contactors can be used in parallel. Such as resistance furnaces, welding transformers, etc. When using several poles in parallel, a smaller capacity contactor can be used. However, it must be noted that after parallel ...

Features of LS SUSOL series circuit breakers Features of LS SUSOL series circuit breakers

Features of SUSOL series circuit breakers: It can be used as the main switch of electrical equipment, and the limit breaking ability is high, Icu=Ics Modular construction of circuit breakers: Tripper replacement (TS series) can be combined in a variety of combinations, such as ...

Introduction of LS AC motors Introduction of LS AC motors

1. AC synchronous motor: that is, the rotor is composed of permanent magnet data, so after rolling, with the change of the stator rotation magnetic field of the motor, the rotor also changes the speed of the response frequency, and the rotor speed = stator speed, so it is called "synchronization". ...

Motor & Electrical Control Technology Tips - LS Electricity Production Motor & Electrical Control Technology Tips - LS Electricity Production

1. Low-voltage electrical appliances: refers to electrical appliances that play the role of on-off, maintenance, control or regulation in circuits with a rated voltage of 1200V and a rated voltage of 1500V and below. 2. Main electrical appliances: electrical appliances used to send control instructions in the automatic control system. 3. Fuse: ...

Debugging of basic parameters of inverter - LS power generation Debugging of basic parameters of inverter - LS power generation

There are many functional parameters of the inverter, and there are generally dozens or even hundreds of parameters for users to choose. In practice, it is not necessary to set and debug every parameter, and most of them only need to use the factory setting value. However, some parameters are very closely related to the application of practice, and some of them are still ...

Inverter fault diagnosis - LS power generation Inverter fault diagnosis - LS power generation

1. How to distinguish between heavy and light faults When there is a problem with the light, the system announces the alarm signal and the fault indicator flashes. When there is a serious problem, the system will announce the problem indicator, the problem indicator will always be on, together announce the order to break the high voltage and stop closing, and store the problem ...

Inverter air boost test step - LS power generation Inverter air boost test step - LS power generation

1. Download the control program. 2. Put the inverter in open-loop experimental mode and set the appropriate parameters. 3. Connect the incoming cable of the inverter. The cable on the output side of the inverter is not connected. 4. Push the high-voltage cabinet to the experimental position, close the switch, and ...

How does the interference of the frequency converter occur? -- Electricity production How does the interference of the frequency converter occur? -- Electricity production

To discuss the disturbance problem of LS inverter, we must first understand the operating principle of inverter, from the structural point of view, inverter is divided into direct inverter and direct inverter. The direct inverter is a communication that directly converts the I frequency current into a controllable frequency, and there is no intermediate DC link. Each phase of it ...

Introduction of LS PLC programming software Introduction of LS PLC programming software

LS PLC programming software is a professional PLC programming assistant tool, providing excellent interface, which can carry out PLC programming operations such as online modification, debugging and self-diagnosis, packing and debugging, etc., compatible with LG Master-K series and LG MASTER-K series, which can make you in the process of processing in a timely manner.

LS static test to determine the fault of the inverter LS static test to determine the fault of the inverter

Generally, the general-purpose inverter roughly includes the following parts: (1) rectifier circuit; (2) DC central circuit; (3) Inverter circuit; (4) Control circuit. The static test is mainly a test of the high-power transistors (power modules) of the rectifier circuit, DC center circuit and inverter circuit. Whole...

Precautions for inverter installation tips - LS power generation Precautions for inverter installation tips - LS power generation

When the line power supply exceeds the driver's kV-A rating by 10 times, add a line reactor. A 3% impedance line reactor should be used to reduce power line transients caused by capacitor switching, line notching, DC bus overvoltage tripping, and inverter overcurrent and overvoltage conditions. Line...

Introduction of plc inverter - LS power generation Introduction of plc inverter - LS power generation

Because the imported products of the inverter brand have their own PLC function, they mainly play an important role in the control effect of mechanical equipment, and play an important role in the equipment, which can regulate the operation and control of the machine and meet the requirements of users. It should be scale pLC ...

The method of judging the quality of components - LS power production The method of judging the quality of components - LS power production

1. Detection of ordinary diodes Use the MF47 multimeter to measure, connect the red and black watch pens to the two ends of the diode, read the reading, and then adjust the watch pen to measure. According to the results of two measurements, the forward resistance value of the general low-power germanium diode is 300-500Ω, and the silicon diode ...

The touch screen controls the inverter steps The touch screen controls the inverter steps

1. The touch screen is controlled by PLC inverter 1. At present, the general control of the inverter needs to use PLC to communicate with the inverter, read the information of the inverter, and then the touch screen communicates with the PLC in order to complete the control of the inverter to start, stop, and monitor the operation of the inverter.

The meaning of servo in LS power production The meaning of servo in LS power production

"Servo" - the word derives from the Greece word for "slave". People want to treat the "servo mechanism" as a handy tame thing, and act in accordance with the requirements of the control signal. The rotor stands still until the signal comes; As soon as the signal arrives, the rotor rolls; When the signal disappears, the rotor can instantly ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383