Introduction to Yaskawa inverter fault codes

Create Date: 2024-8-30 12:03:23|Source: YASKAWA/Yaskawa

1. If the fault code on the Yaskawa inverter is UV1, then it means that the low voltage of the main circuit is lower than the low voltage standard of 200V, at this time, we need to check whether there is a problem with the wiring of the power supply;

2. If the fault code on the Yaskawa inverter is UV2, then it means that the low voltage of the control loop is lower than the low voltage standard, and we need to check whether the capacity of the power supply is normal;

3. If the fault code on the Yaskawa inverter is UV3, it means that the electromagnetic contactor inside the inverter may be faulty

4. If the fault code on the Yaskawa inverter is UV, then there may be an instantaneous power outage, the main reasons are as follows, the first is that the voltage of the main circuit is lower than the voltage standard, and the second possibility is that the contactor is faulty;

5. If the fault code on the Yaskawa inverter is OC, then the output current of the inverter may exceed the output current standard, and we need to check whether the impedance insulation of the inverter is working normally;

6. If the fault code on the Yaskawa inverter is GF, then it means that the inverter has a grounding fault, at this time, I need to check whether the inverter has a fault of insulation deterioration, and at the same time, we also need to check whether the wiring of the inverter is damaged;

7. If the fault code on the Yaskawa inverter is OV, it means that the DC voltage of the main circuit is higher than the overvoltage standard of 200V:

8. If the fault code on the Yaskawa inverter is SC, it means that the inverter has a load short circuit, we need to check whether there is a short circuit on the output side of the inverter, and then check whether the insulation and impedance of the inverter are normal;

9. If the fault code on the Yaskawa inverter is PUF, then it means that the fuse inside the inverter is broken, it may be that the fuse of the main circuit is blown out, or the fuse of the DC circuit is blown out, and then we need to check whether the crystal module is working normally, and then check that the load is not short-circuited.
Introduction to Yaskawa inverter fault codes

More on that
Yaskawa robot maintenance and regular inspection Yaskawa robot maintenance and regular inspection

For the maintenance of Yaskawa robots, maintenance should be carried out before and after each use, check whether there is damage to the outside of the robot, and check whether the robot movement is abnormal. Then be sure to check the battery frequently, and if you find that the battery is not working, you should replace it as soon as possible. The gearbox should be checked frequently to see if there is ...

What is the reason for Yaskawa servo alarm AF5? What is the reason for Yaskawa servo alarm AF5?

1. When the control power supply is put in, it is caused by the failure of the servo unit circuit board, and the servo unit needs to be replaced. 2. When it occurs in servo ON, then it is caused by the failure of the servo unit circuit board or the short-term motor power line, and the servo unit or motor needs to be replaced.

Yaskawa inverter - maintenance method of low-voltage inverter Yaskawa inverter - maintenance method of low-voltage inverter

1. Countermeasures to the overheating problem of inverter 1. For places where the operating environment temperature of the inverter is high, it is recommended to reduce the temperature of the inverter and strengthen cooling and ventilation; 2. Increase the frequency of regular maintenance of inverter fans, air ducts, etc., so as to improve the operating environment of the inverter, so that the inverter ...

The cause and treatment method of Yaskawa servo drive alarm code B32 The cause and treatment method of Yaskawa servo drive alarm code B32

Fault description: Current detection fault 2 Cause: V-phase current detection loop fault Solution: When the power is turned on again and the alarm still occurs, it may be a servo unit failure. Replace the servo unit. Here's how to solve it The supply voltage exceeds the specification range ...

Yaskawa Robotics - technical performance characteristics of dresspacks for industrial robots Yaskawa Robotics - technical performance characteristics of dresspacks for industrial robots

1. Technical performance characteristics of industrial robot dresspack - intelligence The reason why the intelligent type is placed at the back of the Z is because compared with the mainstream demand for robot dresspacks in the market (that is, strong, fast, and accurate), it is not the most urgent for the time being. This also reflects the ...

Yaskawa arc welding robot reported that the voltage detection line was abnormal Yaskawa arc welding robot reported that the voltage detection line was abnormal

1. First turn off the power - and pull down the power switch. 2. Secondly, use a pen to check the voltage feedback line of the cable behind the base of the robot to see if it is connected or loose. 3. Finally, confirm the abnormality for maintenance. Other error alarm codes can also be used according to the abnormal message under the welder...

Types and applications of Yaskawa's high-temperature resistant robot protective clothing Types and applications of Yaskawa's high-temperature resistant robot protective clothing

Yaskawa robot is a kind of industrial robot, which can be applied to various automated production lines according to its specifications and models, and the high-temperature work workshop is a major field where industrial robots are used more, so it needs to be protected by robot protective clothing. The following is a brief introduction to Ontor ...

Yaskawa servo motor MP2300/MP2310/MP2300S function introduction Yaskawa servo motor MP2300/MP2310/MP2300S function introduction

It is an all-in-one controller with built-in power supply, CPU, communication and servo control. From simple positioning and interpolation to advanced multi-axis control, we are looking for cost-effective devices. Compatible with open networks Just install the optional module in the slot, which not only corresponds to the open network, but also ...

Yaskawa Servo Drive FAQ (10-18) Yaskawa Servo Drive FAQ (10-18)

[10] Yaskawa servo back to the origin can not find the C phase pulse, Yaskawa servo drive and motor, using the travel switch + C phase back to zero mode, now the pressure on the switch deceleration can not find the C phase pulse, servo motor, drive, host computer, which fault is the most likely? A: Servo motor rotation ...

Common fault causes and solutions for servo drives Common fault causes and solutions for servo drives

1. The LED light is green, but the motor does not move (1) Cause of failure: The motor in one or more directions is prohibited from operating. Solution: Check the +INHIBIT and –INHIBIT ports. (2) Cause of failure: The command signal is not to the driver signal. ...

How to use the inverter and adjust the parameters How to use the inverter and adjust the parameters

First, the use of the inverter: (1) First connect the power supply, link the inverter with the motor, and ensure that the working voltage of the inverter and the power of the motor meet the requirements. (2) Set the parameters of the inverter, adjust the speed and load of the motor to ensure the normal operation of the motor.

YASKAWA The success of industrial automation starts here YASKAWA The success of industrial automation starts here

Founded in 1989, Yaskawa Motoman is a leading industrial robotics company in the Americas. With more than 400,000 Motoman industrial robots, 15 million servos and 26 million inverter drives installed worldwide, Yaskawa provides automation products and ...

Performance characteristics of Yaskawa servo motors Performance characteristics of Yaskawa servo motors

Superior performance "I hope to run the machine at a faster speed and with higher precision" ----∑-V. series servo, the performance of which is the best in the industry. It has the highest amplifier responsiveness in the industry, which greatly shortens the setting time It is only 1/12 of our conventional products ...

The causes and treatment methods of the fault of the SC of Yaskawa inverter The causes and treatment methods of the fault of the SC of Yaskawa inverter

1. The inverter shows that SC refers to the drive fault. 2. Cause of failure: 1. The output side of the inverter is interphase or short circuit to the ground. 2. The inverter module is damaged. 3. Handling method: 1. Remove the load, power on normally and turn on the machine, check if there is a three-phase ...

What are the faults of Yaskawa inverter? What are the faults of Yaskawa inverter?

The following are the common faults of the inverter and how to deal with them 1) OC Over Current This is the most frequent failure of the inverter, and it is divided into external and internal causes in the analysis of causes. External causes: mechanical structure and parameter setting, open-loop control ...

Explain in detail the setting method of arc static during welding of Yaskawa welding robot Explain in detail the setting method of arc static during welding of Yaskawa welding robot

1. Conditions for the static characteristics of the arc of Yaskawa welding robots In the welding production process, once the electrode material, gas medium and arc length are maintained, as long as the arc of the Yaskawa welding robot can burn stably, the welding current and arc voltage will show corresponding changes.

Yaskawa Electric – inspection work before motor operation Yaskawa Electric – inspection work before motor operation

(1) Check and remove the dust and debris on the motor; (2) Check whether the voltage, frequency and power supply voltage and frequency on the nameplate of the motor are consistent with the actual situation, and whether the connection method is correct. (3) Use the insulation resistance meter to measure the phase and phase and phase of the motor winding.

What are the fault codes of Yaskawa inverter What are the fault codes of Yaskawa inverter

The fault codes of Yaskawa inverters are as follows: OC overcurrent; PG wiring is disconnected or wiring is incorrect; GF output ground fault ground short circuit ; PUF fuse blowing fuse blowing ; OV Main circuit overvoltage Main circuit overvoltage ...

How to deal with Yaskawa servo alarm 840? How to deal with Yaskawa servo alarm 840?

1. Encoder malfunction. When the power is turned on again and this alarm still occurs, it is possible that the servo motor is faulty, and the servo motor is replaced; 2. Encoder malfunction due to noise and other interference. Correct handling of the wiring around the encoder (separating the encoder cable from the servo motor ...

Yaskawa Robotics - Top 10 Trends in the Industrial Robot Automation Industry Yaskawa Robotics - Top 10 Trends in the Industrial Robot Automation Industry

1. The demand for smart sensors is increasing Quality inspection is a key component in all industries. Analyzing everything from food to phone covers ensures that consumers can trust the goods they receive. Smart sensors enable manufacturers to more efficiently handle this ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top