1) Survey and research method. The investigation and research method is to "see", "listen", "smell", "touch" and "ask" to understand the significant faulty phenomena; After visiting the operator, understand the cause of the problem; A common way to help find faults after consulting others or consulting information ...
|
|
The difference between Schneider verification, calibration, and calibration
What is the difference and contact between the instrument, external work verification, calibration, and calibration?
Verification, calibration, and calibration are all static measurement processes that are carried out in cycles. The meanings are:
The verification ---- shall be arranged by the legal metrology department or the statutory authorization in accordance with the verification procedures, after ...
|
|
The operation essentials of Schneider disconnectors
Schneider Barrier Features: First of all, Schneider Barrier Switch can be used to block the power supply, it is able to disconnect the live equipment from the high-voltage maintenance equipment, and it can also see a significant disconnection point on it. Secondly, the Schneider barrier switch can be used with the circuit breaker to change the operation of the system.
|
|
The difference between an inverter and a servo drive – Schneider
In terms of frequency converters:
The abbreviated inverter can only regulate the speed of the communication motor, and the open-loop or closed-loop can be determined depending on the control method and the inverter, which is the traditional V/F control method. Now many of the frequency conversion has been set up by mathematical models, which will communicate electricity ...
|
|
Schneider circuit breaker maintenance method
1. Insist that the air is moist or unclean, and the pipes are not clean, which may have the following consequences:
(1) The wet gas is decomposed into mixed gases such as hydrogen and oxygen under the effect of arcing, destroying the insulation between the fractures after the main contact is broken, which is difficult to arc or arc re-ignition, and in severe cases, arc extinguishing will be formed.
|
|
Is there a restriction on the installation direction when Schneider installs the inverter?
It should be basically stored in the plate, the problem is that the plate with a fully enclosed structure is large, takes up a lot of space, and the cost is relatively high. This can be done by:
(1) The planning of the disc should be based on the heat dissipation required by the actual device;
(2) Profit ...
|
|
The type of signal output from the Schneider sensor
The type of sensor output signal
Sensors are commonly used detection devices that convert perceived information into electrical signal outputs, and are used in a variety of applications. What can be divided into the output signal mode of the sensor ...
|
|
Schneider inverter Eplan file download
Product line:
Frequency converters and soft starters
Solution(s):
All Eplan software users can visit the Eplan website (directly from the Eplan software). The EPLAN database includes ...
|
|
Common analysis method for electrical control line faults - Schneider
1) Survey and research method. The investigation and research method is to understand the obvious problem phenomena through "seeing", "listening", "smelling", "touching" and "asking"; After visiting the operator, understand the cause of the failure; A common way to help find the fault point after asking others or consulting information ...
|
|
Maintenance of multiple models of Schneider inverters
Schneider inverter our most common problem is that the power is not visible, the series of inverter switching power supply uses a UC2842 chip as a waveform generator, the damage of the chip will lead to the switching power supply can not operate, so that it can not be displayed normally, in addition, the operating power supply of the chip is not ...
|
|
Schneider thermal relay selection method
1. In principle, the ampere-second characteristics of the Schneider thermal relay should be as close as possible to or even coincide with the overload characteristics of the motor, or under the overload characteristics of the motor, and at the same time, the Schneider thermal relay should not be affected (not acting) at the moment of short-term overload and start of the motor.
...
|
|
Frequency characteristics of frequency converters – Schneider
a. Output frequency scale. The output frequency scale that can be controlled by the general inverter, the lowest starting frequency is generally 0.1Hz, and the highest frequency varies according to the functional indicators of the inverter, generally 400Hz, and some models are 650Hz. No matter how high the output frequency is, it depends on the scale of the high-frequency inverter.
...
|
|
Schneider instrumentation maintenance precautions
1. Don't blindly knock and bump when overhauling to avoid expansion failures, and the more you repair, the worse it gets.
2. Do not plug and unplug various control boards and plugs with electricity. Due to the strong induced electromotive force generated by plugging and unplugging the control board under the power-on condition, the instantaneous ...
|
|
Schneider UPS power supply common fault analysis
1. When there is mains power, the UPS output is normal, and when there is no mains power, the buzzer beeps for a long time and there is no output
Fault analysis: From the phenomenon to identify some problems of the battery and inverter, you can view it according to the following procedures:
1. Check the battery voltage to see if the battery is undercharged.
|
|
Line leakage detection method - Schneider
Line leakage detection method, leakage check method summary, if a closing, leakage switch will trip, this kind of front leakage, check the method is as follows:
1. Disconnect all the separation gates, close the main gate, close the separation gates one by one, and close them to ...
|
|
Is there still an output after the UPS power is turned off?
1. After the UPS power supply is shut down, the output terminal is still powered, but the UPS power supply does not play a role at this time, and it is in a bypass state.
2. The power supply will not be cut off after the UPS power supply is shut down, because the UPS power supply will go bypass after the shutdown, there is still a mains power input at this time, ...
|
|
The difference between Schneider miniature circuit breaker and leakage switch
1. Definition of miniature circuit breaker
The electrical occupation is referred to as MCB, which is suitable for communicating 50/60Hz additional voltage 230/400V, additional current to 63A line overload and short circuit maintenance, and can also be used as infrequent operation conversion of the line under normal circumstances.
...
|
|
Advantages and disadvantages of closed busbars compared with open busbars - Schneider
The advantages of closed busbars over open busbars are:
1) Closing the bus duct can reduce the grounding fault, avoid the short circuit between phases, basically eliminate the grounding defect caused by external moisture, dust and foreign objects, and improve the continuity of generator operation.
2) Eliminate ...
|
|
Schneider PLC intelligent parameter features
Characteristic:
1. NEZA PLC (TSX08 series)
EZA series is a small PLC with rich functions, high performance-to-price ratio, small size and strong versatility.
A new generation of handheld programmer - Chinese PDA PL707WinCE, supports Chinese interface, whether it is programming, ...
|
|
Schneider circuit breakers, contactors, thermal relays selection
In daily work, the combination of circuit breaker, contactor and thermal relay is the most common combination of motor power supply circuit, and the circuit breaker is generally the short-circuit instantaneous action of magnetic maintenance, the contactor realizes relay logic control, and the thermal relay overload maintenance. The parameter selection method of these three kinds of gas parts is as follows: ( ...
|