The air switch is divided into the upper inlet line and the lower inlet line of the power supply, 1 is - 3 is + 2 is + 4 is - when the upper line is inlet, 2 is + 4 is - This is related to the internal trip curve.
DC circuit breaker: used for DC system operation method conversion or fault removal. Such as metal return conversion circuit breaker (MRTB), earth return transfer switch (GRTS). Discipline of use: Electricity; The transformer tap-changer voltage regulation method of high-voltage DC transmission load regulation refers to the difference in that the non-excitation voltage regulator switch does not have the ability to bring load conversion gear, because this tap-changer has a short-term disconnection process in the process of conversion gear, and the disconnection load current will cause the arc between the contacts to burn out the tap-changer or short circuit, so it is necessary to make the transformer power out when adjusting the gear.
It is generally used for transformers that are not very strict in voltage requirements and do not need to be adjusted frequently. The on-load tap-changer can switch gears with load, because the on-load tap-changer does not have a short-term disconnection process in the process of shifting, and transitions from one gear to another gear through a transition resistor, so that there is no arcing process of load current disconnection.
DC circuit breaker DZ47-63Z/1P has a first-class current limiting function, which can accurately maintain relay maintenance and automatic devices from overload, short circuit and other faults.
DC circuit breaker DZ47-63Z/1P adopts a special arc extinguishing to quickly break the faulty current of the DC distribution system, so that the gradation coordination has been greatly improved. DC circuit breaker DZ47-63Z/1P especially for the power engineering DC system between the test and protection screen and the distribution screen presented by the tripping and other incidents, small DC circuit breaker DZ47-63Z/1P series has excellent functions, can prevent the above problems.
|
More on that
|
Schneider instrumentation accuracy
It refers to the degree to which the average value measured repeatedly under certain test conditions is consistent with the true value, which is indicated by error. It is used to indicate the magnitude of the error in the system. In practice, control tests are generally carried out with standardized substances or normative methods, and when there are no standardized substances or normative methods, it is often used to add ...
|
|
Precautions for the selection of Schneider foot switches
The foot switch series is XPE, and it should be noted when selecting:
1) Raw materials: metal and plastic, which are used in heavy-duty, high-risk, light-duty, low-risk occasions.
2) Pedal: divided into single pedal and double pedal (type end plus D).
3) With or without maintenance cover ...
|
|
Schneider Instrumentation Classification Standard
The classification specifications for the appearance of the instrument are as follows:
The appearance of the instrument is a comprehensive product of a variety of science and technology, with a wide variety of varieties, wide application, and constantly updated, and a variety of classification methods. According to the purpose and use of the use of the main measuring instrument, car appearance, tractor appearance, marine ...
|
|
Schneider selection of different types of circuit breakers
Schneider miniature circuit breakers are:
A9 (iC65, iDPN, etc.), M9 (C65, DPN, C120, NG125, etc.), E9, OSMC32N/OSMC65H, etc
Schneider molded case circuit breakers are:
NSX, NSE, EZD, NSC, large plastic case NS
Schneider structural circuit breakers have ...
|
|
About the characteristics of Schneider explosion-proof inverter cabinet
1. Aluminum alloy shell or steel plate welding, surface spraying;
2. Built-in inverters, circuit breakers, signal lights and other components produced by domestic or Schneider and other companies;
3. It mainly regulates ordinary three-phase by changing its output frequency ...
|
|
The 7 peripherals of the inverter governor - Schneider
1. Air circuit breaker is an active electrical appliance that can not only touch and disconnect the circuit normally, but also operate under abnormal conditions such as overcurrent, reverse current, short circuit and loss (under)voltage. Its primary role is to maintain the electrical equipment in the AC and DC circuits, and it can also operate the circuits infrequently. ...
|
|
Schneider Electric Innovation Summit "The future is digital"
The name of a company's product was mentioned more than anyone could remember, but on the first day of the Schneider Electric North America Innovation Summit in Atlanta on Tuesday, another word appeared even more often ...
|
|
Inverter selection and capacity matching method - Schneider
How to carry out the selection of inverter normally, is the difficulty faced by many enterprise technical personnel and business personnel, in addition, the selection of the inverter body alone, without considering whether the inverter selection and capacity matching is appropriate, is also unscientific.
...
|
|
Schneider relay model introduction
RM4 Series Control Relay (Three-phase Power Control)
RM4 series voltage steerable relays
RM4 current operated relay
RM4 level control relay
RM17 three-phase power controller
RM35 3-phase power control relay
RM17 Voltage Steerable Relay ...
|
|
Schneider ATV71 selection and letter meaning
The type of Schneider inverter generally reflects the rated voltage, rated power, and load requirements of the inverter (heavy or light load).
Here are two examples:
Example 1:
Schneider Inverter Type: ATV71HD11N ...
|
|
Precautions for trial operation of Schneider motors
1. Check during the test run of the motor
1.1 Before the motor starts
It is necessary to carefully check whether the insulation resistance is qualified, check whether the wiring of the secondary circuit is correct, and the inside of the motor should be boring, clean and free of debris. Investigate whether the fastening bolts of the motor are loose and the bearing is ...
|
|
Schneider touch screen touch deviation causes
(1) Problem--: Contact deviation
Phenomenon 1: The direction of the finger does not coincide with the mouse arrow.
Reason 1: After installing the driver, there is no vertical contact with the bullseye center when calibrating the alignment. Deal 1: Correct the position from the beginning.
Phenomenon 2: Some districts ...
|
|
Schneider inverter ATV310 instruction with given
The instructions of the inverter are given with the given
conf→400-
→ 401 (given channel), → 01 (given analog terminal), 163 (given by remote display terminal), 164 (given by mudobus communication), 183 (navigation knob ...
|
|
Schneider ATV series inverter used as inverter power supply?
Can Schneider ATV series inverter be used as a variable frequency power supply?
No, you can't. The inverter is a control device designed according to the characteristics of the communication asynchronous motor, and cannot be used as a variable frequency power supply.
The entire circuit of the variable frequency power supply is composed of a ditch ...
|
|
Frequency converter control motor leakage solution - Schneider
Because the current at the input and output ends of the inverter contains high-frequency components, the leakage current formed by the high-frequency components when the inverter is driven is greater than that when the grid power supply is supplied. Because there are many varieties of circuit breakers, in some cases, even the inverter wires and motors ...
|
|
Selection and control of the inverter installation - Schneider
Frequency converters are widely used equipment in modern industry. If you want to complete the functions of soft stop, soft start, stepless speed regulation or special requirements for speed rise and fall, you need the more advanced speed control equipment in modern asynchronous motors - frequency converters. The main circuit of the equipment is selected to communicate - DC - communication ...
|
|
Schneider touch screen touch deviation causes
(1) Problem 1: Contact deviation
Phenomenon 1: The direction of the finger does not coincide with the mouse arrow.
Reason 1: After installing the driver, there is no vertical contact with the bullseye when checking the alignment. Deal 1: Correct the position from the beginning.
Phenomenon 2: ...
|
|
NSX molded case circuit breaker selection - Schneider
The Schneider NSX molded case circuit breaker has a double rotary contact construction for maintenance, and the high-end electronic trip unit allows for accurate measurement and easy communication. Schneider NSX molded case circuit breaker conforms to IEC60947-2, GB14048.2, China's CCC certification and multinational classification certification...
|
|
Causes of Schneider UPS power supply damage
1. Air conditioning: It is generally forbidden to use UPS power supply, because the air conditioning is very large and belongs to the rational load.
Not suitable for belt loads
2. Motor: It is necessary to choose a large-capacity UPS power supply, because it is a rational load, and it is ...
|
|
Schneider inverter knowledge points
1. Use the analog output port to indicate the motor frequency, when the motor frequency is 50Hz, why is the output only 16mA?
Due to the maximum output frequency parameter of the inverter "TFR", the factory default value is 60Hz. So when the inverter output is 50Hz, the analog output is 16mA. At this time, only ...
|
|