The instructions of the inverter are given with the given
conf→400-
→ 401 (given channel), 0→1 (given analog terminal), 163 (given by remote display terminal), 164 (given by mudobus communication), 183 (given by navigation knob) [press two seconds OK]
→ 406 (channel configuration parameters) →02 (separation form) 407 are visible
→407 (command parameters)→01 (terminal control), 02 (local panel control), 03 (remote display terminal control), 10 (modbus control) [press two seconds OK]
|
More on that
|
Schneider UPS power supply common fault analysis
1. When there is mains power, the UPS output is normal, and when there is no mains power, the buzzer beeps for a long time and there is no output
Fault analysis: From the phenomenon to identify some problems of the battery and inverter, you can view it according to the following procedures:
1. Check the battery voltage to see if the battery is undercharged.
|
|
Advantages and disadvantages of closed busbars compared with open busbars - Schneider
The advantages of closed busbars over open busbars are:
1) Closing the bus duct can reduce the grounding fault, avoid the short circuit between phases, basically eliminate the grounding defect caused by external moisture, dust and foreign objects, and improve the continuity of generator operation.
2) Eliminate ...
|
|
Solutions to Schneider drive fault codes
PHF: 1. The power supply of the inverter is not right or the fuse is blown; 2. There is a transient problem in a certain phase. 1. Check the power connection and fuse; 2. Reset.
USF: 1. Power supply voltage undervoltage; 2. Instantaneous voltage drop; 3. The load resistor is damaged. 1 Check the power supply voltage; 2 Substitutions ...
|
|
Frequency converter main circuit fault solution - Schneider
According to the statistical analysis of the frequency and shutdown time of the specific common problems of the inverter, the repair rate of the main power supply circuit accounts for more than 60%; The main operating parameters are set improperly, resulting in about 20% of common problems; 15% of the common problems of manipulating circuit boards; 5% of common problems are caused by incorrect operation and external anomalies ...
|
|
Calculation method of inverter capacity - Schneider
1. Accounting of inverter capacity when the load is continuously changed periodically
In many cases, the load of the motor changes periodically. Obviously, in this case, picking the capacity of the inverter according to the minimum load will be overloaded, and it will be uneconomical to select according to the maximum load.
|
|
Schneider ATS48 soft starter issue
1. What type of ATS48 power supply is?
The control power supply of ATS48 selects communication input, and supplies power to the controller, input and output ports through internal power processing;
The control power supply of Q series products is 220V-415V;
Handling of the Y-Series ...
|
|
Maintenance and overhaul of frequency converters and soft starters
The protection and viewing of inverters and soft starters is a useful means to prevent occasional equipment problems. In order to be useful for protection and inspection, inspection orders should be created to record and save the inherent characteristics of the equipment and the stability of the constituent parts, so as to prevent problems and problems that occur.
|
|
Motor encoder alarm causes and solutions - Schneider
1. The cause of the problem
(1) Wiring fault;
(2) electromagnetic interference;
(3) Encoder hardware damage caused by mechanical vibration;
(4) Pollution caused by the on-site environment;
2. Troubleshooting
(1) Check the wiring and exclude ...
|
|
Precautions for trial operation of Schneider motors
1. Check during the test run of the motor
1.1 Before the motor starts
It is necessary to carefully check whether the insulation resistance is qualified, check whether the wiring of the secondary circuit is correct, and the inside of the motor should be boring, clean and free of debris. Investigate whether the fastening bolts of the motor are loose and the bearing is ...
|
|
Switching power supply circuit fault phenomenon - Schneider
1. The power supply voltage of the secondary load is 0V. There is no response after the inverter is powered on, there is no indication on the operation display panel, and the 24V and 10V voltages of the measurement and control terminals are 0V. Check that the charging resistance or pre-charging circuit of the main circuit is correct, which can be identified as a switching power supply fault. The overhaul process is as follows:
1 ...
|
|
The reason for the inverter trip - Schneider
Whenever the inverter is down due to a problem, a problem code will appear. The most common causes are overcurrent, overvoltage, inverter temperature, etc. It's a good idea to find an explanatory book with specific questions to be asked about.
1. Overload jump ...
|
|
The difference between Schneider and Siemens PLC
There are three main differences, namely: different uses, different products, and different characteristics.
1. Different use cases: The programmable manipulator produced by Siemens in Germany is also widely used in China, and has been used in metallurgy, chemical industry, printing production lines and other fields.
|
|
Functions of input/output pins P0, P1, P2, P3 – Schneider
P0.0——P0. 7 : Port P0 is an 8-bit open-drain bidirectional I/O port. When visiting off-chip memory, it is time-shared for a low-8-bit address and an 8-bit bidirectional data bus. When EPROM is programmed, the instruction byte is input by P0, and when the program is verified, it outputs ...
|
|
Schneider selection of different types of circuit breakers
Schneider miniature circuit breakers are:
A9 (iC65, iDPN, etc.), M9 (C65, DPN, C120, NG125, etc.), E9, OSMC32N/OSMC65H, etc
Schneider molded case circuit breakers are:
NSX, NSE, EZD, NSC, large plastic case NS
Schneider structural circuit breakers have ...
|
|
Analysis of 10 reasons for frequent tripping of Schneider leakage switches
1. Defective device
If the lead wire of each pile head is not firmly connected and loosened for a long time, it will cause the pile to heat and oxidize, burn out the outer insulation of the wire, and announce sparks and burnt smell, resulting in undervoltage of the line and air switch action.
2. Leakage switch with ...
|
|
Schneider inverter ATV61 OPF failure analysis
Q: 250KW ATV61 with 250KW fan, when decelerating to low speed, OPF (motor missing three-phase) problem will be reported occasionally. There are no contactors or switches between the inverter and the motor.
Answer: This situation seems to be a problem with the inverter, which is a false alarm. Not really! The fan is decelerating ...
|
|
Schneider inverter maintenance power settings, waveform test problems
1. After the inverter is repaired, the power number needs to be modified, don't forget it
Generally, an inverter corresponds to a power number (also known as the number of horsepower), for example, a 75 kilowatt inverter is set under heavy load, and 100 kilowatts is set under light load. In this way, the customer will not use it to present ...
|
|
Inverter power settings, waveform test issues
1. After the inverter is repaired, the power number demand is corrected, don't forget
Generally, an inverter corresponds to a power number (also known as the number of horsepower), for example, a 75 kilowatt inverter is set under heavy load, and 100 kilowatts is set under light load. In this way, the customer will not use it to present ...
|
|
How to operate the transformer DC resistance tester – Schneider
1. The instrument test has a total of YN winding three-phase test, YN winding three-phase phase-by-phase test, low-voltage winding magnetization method test of iron-core five-column low-voltage angular transformer, low-voltage winding phase selection test and general four-terminal method of ironcore three-column low-voltage angular transformer.
...
|
|
How to distinguish the authenticity of Schneider products
One. QR code scanning
Mainly for low-voltage power distribution and industrial control products produced from September 25, 2013
Method: Scan the QR code on the left side of the product anti-counterfeiting label to enter the self-service inquiry channel
Two. The official website ...
|
|