1. What is the difference between high-voltage inverter and low-voltage inverter?
Frequency converters can be broadly divided into two categories: high-voltage frequency converters and low-voltage frequency converters.
In terms of use, the applicable objects are different, and the high-voltage motor is the same from the principle of speed regulation. From the perspective of topology, the two are very different, mainly because of the lack of withstand voltage of IGBT modules, which are widely used. Due to the high voltage, the high-voltage inverter also has a large disturbance to the driving circuit, etc., and the optical fiber is generally used to block it.
2. Why does the output voltage of the inverter change in proportion to the frequency?
The torque of the asynchronous motor is the interaction between the magnetic flux of the motor and the current flowing in the rotor, under the additional frequency, if the voltage must only drop the frequency, then the magnetic flux is too large, the magnetic circuit is saturated, the motor current increases, and the motor will be burned out when it is severe. Therefore, the frequency and voltage should be changed in parts, that is, the output voltage of the inverter is controlled together with the changed frequency, so that the magnetic flux of the motor is maintained and the occurrence of magnetic saturation is avoided. This is the VVVF theory. The voltage here refers to the line voltage or phase voltage RMS of the motor.
3. When the motor is driven by power frequency power supply, the current is added when the voltage drops; Regarding the inverter drive, if the voltage drops when the frequency drops, does the current increase?
When the frequency drops (low speed), the current is added if the same power is output, but the current is simply unchanged when the torque is constant.
4. When the inverter is selected, what is the starting current and starting torque of the motor?
The inverter is selected to work, and the starting current is limited to less than 150% of the additional current (125%-200% according to the different models) with the acceleration of the motor. When the industrial frequency power supply is started directly, the starting current is 6-7 times, therefore, the mechanical and electrical shock will occur. The inverter drive can be used to start smoothly (the starting time becomes longer). The starting current is 1.2-1.5 times of the additional current, and the starting torque is 70%-120% of the additional torque; For the inverter with the active torque enhancement function, the starting torque is more than 100%, and it can start with full load.
5. What does the V/f form mean?
When the frequency drops, the voltage V also decreases in shares, and this question has been clarified in Answer 4. Maintaining the stable control of the V/f ratio is the most fundamental control method of the frequency conversion speed regulation of the asynchronous motor, which controls the voltage output of the inverter together with the change of the power supply frequency of the control motor, and makes the ratio of the two V/f stable, so that the magnetic flux of the motor remains stable. In the case of additional operation of the motor, the voltage drop of the stator resistance and leakage impedance of the motor is relatively small, and the terminal voltage of the motor and the induced potential of the motor are approximately equal.
The main problem with V/f ratio stability control is poor low-speed function. The reason is that the share of the stator resistance voltage drop of the asynchronous motor at low speed becomes larger, which can no longer be ignored, and the stator voltage and the induced electric potential of the motor can no longer be considered to be approximately equal, and the motor magnetic flux can no longer be maintained stable according to the V/f ratio. The decrease of the magnetic flux of the motor must lead to the reduction of the electromagnetic torque of the motor; In addition, the dead time of the inverter power equipment is also an important reason for the low-speed function of the motor, and the voltage drop at the dead time will also cause torque ripple, and the oscillation of speed and current will also be caused under certain conditions.
V/f ratio stabilization is often used on general-purpose inverters. This kind of inverter is mainly used for the speed regulation function of fans and pumps, as well as for occasions where the speed regulation scale is not high. The outstanding advantage of V/f ratio stable control is the ability to operate the open-loop speed of the motor.
6. How to change the torque of the motor when changing V and f according to shares?
If the voltage drops completely and proportionally when the frequency drops, the communication impedance decreases while the resistance does not change, and the torque that occurs at low speeds tends to decrease. Therefore, given V/f at low frequency, the output voltage should be improved a little in order to obtain a certain starting torque, and this compensation is called enhanced starting. It can be achieved by various methods, such as active methods, V/f form selection or potentiometer adjustment.
7. What does the so-called open loop mean?
The speed sensor is installed on the motor used, and the practical speed is fed back to the control device for control, which is called "closed loop", and the speed sensor is called "open loop" if it does not work, and the general inverter is mostly open loop method.
8. The protection function of the high-voltage inverter itself
Output overload, output overcurrent, grid overvoltage, grid undervoltage, grid power loss, DC bus overvoltage, DC bus undervoltage, transformer overheating, phase loss, power control power failure, drive failure, power equipment overheating, heat dissipation fan failure, external given disconnection, grounding failure, optical fiber failure, etc.
|
More on that
|
Schneider ATV312 inverter failure
1. OLF is motor overload.
Possible reasons: 1. Triggered by high motor current. 2. The value of the [cold stator resistance] (rSC) parameter is wrong.
Corrective measures: 1. Check the [Motor Thermal Current] (ItH) setting of the motor thermal maintenance function and check the motor load. Wait...
|
|
The reason for the inverter trip - Schneider
Whenever the inverter is down due to a problem, a problem code will appear. The most common causes are overcurrent, overvoltage, inverter temperature, etc. It's a good idea to find an explanatory book with specific questions to be asked about.
1. Overload jump ...
|
|
Introduction of Schneider Electric three-phase uninterruptible power supply
Sensitive operation form, satisfactory business operation policy:
Four-level inverter technology: Galaxy VX uses innovative patented four-level inverter technology to reduce power consumption and pressure on power components, and complete the perfect unity of high power and component reliability.
Sensitive operating form ...
|
|
Inverter fault repair - Schneider
To repair the output board driven by the inverter, we must first investigate whether the components on the PCB board are burned out, replace them first, and then analyze what causes the burned out and deal with this problem.
And then...
|
|
Inverter braking resistor selection – Schneider
In the process of fast parking, because of the inertia, a lot of regenerative electric energy will occur, which will directly act on the intermediate DC part of the inverter, and if this part of the electric energy is not consumed, the inverter will be faulty or the inverter will be damaged. The braking resistor is used to dissipate this part of the electrical energy. ...
|
|
NSX molded case circuit breaker selection - Schneider
The Schneider NSX molded case circuit breaker has a double rotary contact construction for maintenance, and the high-end electronic trip unit allows for accurate measurement and easy communication. Schneider NSX molded case circuit breaker conforms to IEC60947-2, GB14048.2, China's CCC certification and multinational classification certification...
|
|
The operation essentials of Schneider disconnectors
Schneider Barrier Features: First of all, Schneider Barrier Switch can be used to block the power supply, it can disconnect the live equipment from the high-voltage maintenance equipment, and it can also see a significant disconnection point on it. The second is that Schneider Barrier Switches are able to work with circuit breakers to reach the point where the operation of the system is changed.
|
|
Schneider ATV71 selection and letter meaning
The type of Schneider inverter generally reflects the rated voltage, rated power, and load requirements of the inverter (heavy or light load).
Here are two examples:
Example 1:
Schneider Inverter Type: ATV71HD11N ...
|
|
How Schneider contactors work
How it works
Contactor refers to an electrical appliance that uses a coil to flow through an electric current to generate a magnetic field, so that the contact is closed, and then the load can be controlled. Because it can quickly block the main circuit and frequently connect with the equipment of the high-current control circuit, it has been used in electrical engineering.
|
|
The difference between Schneider verification, calibration, and calibration
What is the difference and contact between the instrument, external work verification, calibration, and calibration?
Verification, calibration, and calibration are all static measurement processes that are carried out in cycles. The meanings are:
The verification ---- shall be arranged by the legal metrology department or the statutory authorization in accordance with the verification procedures, after ...
|
|
Frequency characteristics of frequency converters – Schneider
a. Output frequency scale. The output frequency scale that can be controlled by the general inverter, the lowest starting frequency is generally 0.1Hz, and the highest frequency varies according to the functional indicators of the inverter, generally 400Hz, and some models are 650Hz. No matter how high the output frequency is, it depends on the scale of the high-frequency inverter.
...
|
|
Schneider improves plant performance with automated control
1. Engineering planning one by oneWith data at their fingertips and intelligent and sensitive functions, engineers can easily plan and test equipment, improve process availability, and easily complete system integration together – ultimately reducing the planning time by up to 25%.
...
|
|
Schneider Electric Innovation Summit "The future is digital"
The name of a company's product was mentioned more than anyone could remember, but on the first day of the Schneider Electric North America Innovation Summit in Atlanta on Tuesday, another word appeared even more often ...
|
|
Is there still an output after the UPS power is turned off?
1. After the UPS power supply is shut down, the output terminal is still powered, but the UPS power supply does not play a role at this time, and it is in a bypass state.
2. The power supply will not be cut off after the UPS power supply is shut down, because the UPS power supply will go bypass after the shutdown, there is still a mains power input at this time, ...
|
|
Schneider servo model introduction
LXM23DU01M3X servo drive 0.1 kW
LXM23DU02M3X servo drive 0.2 kW
LXM23DU04M3X Servo drive 0.4 kW
LXM23DU07M3X Servo drive 0.75 kW
LXM23DU10M3X ...
|
|
AC-DC inverter composition and function - Schneider
The AC-DC inverter main circuit consists of three components: the rectifier main circuit, the center circuit and the inverter circuit.
1. The main circuit is the power replacement part that provides voltage regulation and frequency regulation power supply for the asynchronous motor, and the main circuit of the inverter can be roughly divided into two categories: the voltage type is the voltage source ...
|
|
The role of Schneider instrumentation in the air separation process
The appearance of the instrument plays a very important role in the air separation equipment and gas purification process, and it is indispensable for the adjustment of the air separation process and the detection of product quality. Because there are different types of on-line profiles for monitoring targets in different gaseous media at each stage of the ASU process, the ...
|
|
Inverter selection and capacity matching - Schneider
In addition, it is unscientific to select the inverter body alone, without considering whether the inverter selection and capacity matching are appropriate.
...
|
|
Precautions for the use and maintenance of instruments and meters - Schneider
Attention should be paid to the following matters during the use and maintenance of the appearance of the instrument:
1. Don't blindly knock and bump when overhauling, so as not to expand the problem, and the more you repair, the worse it will become.
2. Do not plug and unplug various control boards and plugs with electricity. Due to the power-on ...
|
|
Schneider inverter inverter field interference solution
1. Use software anti-disturbance method
In detail, the carrier frequency of the inverter is lowered through the human-machine interface of the inverter to an appropriate scale. If this method does not work, then the following hardware anti-disturbance method can only be adopted.
2. Carry out positive ...
|
|