Introducing the Reynolds JJR8000 series of intelligent soft starters

Create Date: 2024-8-30 12:03:23|Source: RENLE/RENOLDS

JJR8000 series of intelligent motor soft starter is the use of power electronics skills, microprocessor skills and modern control theory skills to produce today's international first-class starting equipment, the product can constrain the starting voltage of the asynchronous motor when starting, can be used in fans, pumps, conveying and compressors and other heavy-duty equipment, is the star / triangle conversion, self-coupling step-down, magnetron step-down and other step-down equipment ambition replacement products.

                                 Introducing the Reynolds JJR8000 series of intelligent soft starters

Features:

Customized parameters can be selected directly by applying the load type through simple programming;

Three engine parameters are selectable, which is convenient for one motor soft starter to start different motor loads.

The motor reaction voltage is activated to complete the closed-loop control to ensure the successful start of the motor under various working conditions and different loads.

Three starting methods: the output torque that can be obtained by the voltage ramp starting method; Constrained starting current of constant current soft start method; The straight-start soft-start method can directly start the motor soft-starter.

Programmable delay start method, programmable chain control.

There is no phase sequence requirement for the input power supply.

The starting time and parking time can be digitally modified.

It has a variety of protection functions: overcurrent, three-phase current unbalance, overheating, phase loss, motor overload, etc.

The dynamic fault recall function makes it easy to find the cause of the failure.

The starting current and operating current can be found online.

The fieldbus's fully dynamic control monitoring starter is easy to network.

Chinese character flashing function: LCD LCD screen flashes various working parameters. Programming and fault states have text prompt instructions.

A brief introduction to the typical application of the product

Water Pump - Utilize the soft parking function to alleviate the water hammer flashing of the pump when stopped, saving the cost of system repair.

Ball mill - the use of voltage ramp starting, reduce the wear of gear torque, reduce the repair workload, both save time and save money.

Fan - Reduces belt wear and mechanical shock, saving repair costs.

Compressor - the use of current limiting, complete the smooth start, reduce the motor heat, and prolong the service life.

Belt conveyor - through soft start to complete the smooth and gradual starting process, to prevent product displacement and liquid spillage.
More on that
The difference between servo and inverter - Reynolds The difference between servo and inverter - Reynolds

Overload can be different Servo drives generally have 3 times the overload ability, which can be used to overcome the inertial moment of the inertial load at the moment of start-up, while the frequency converter generally allows 1.5 times the overload. Handling precision Servo control ...

Reynolds servo motor selection steps Reynolds servo motor selection steps

According to the requirements of the operating conditions, the appropriate load inertia accounting formula is selected to calculate the load inertia of the organization. According to the load inertia and servo motor inertia, the appropriate servo motor standard is selected. Combined with the inertia and load inertia of the primary servo motor, the acceleration torque and deceleration are calculated.

Introduction to the braking mode of Reynolds inverter Introduction to the braking mode of Reynolds inverter

1. Energy consumption braking: The energy consumption braking method uses the braking resistance set in the DC circuit to absorb the regenerative electric energy of the motor through the chopper and braking resistor, so as to realize the rapid braking of the inverter. 2. Feedback braking: feedback system ...

Reynolds soft starter troubleshooting methods Reynolds soft starter troubleshooting methods

Common troubleshooting methods for Reynolds soft starters.   During the debugging process of the soft starter, the fault light is on, the motor is unresponsive, and the cause of the fault is analyzed: When the starting mode adopts the live mode, the operation sequence is wrong (the correct operation sequence must first deliver the main power supply, and then the control ...

The main circuit of the inverter is composed of Reynolds The main circuit of the inverter is composed of Reynolds

When it comes to inverter repair, it's not enough to understand the above fundamental circuits, but also to understand the following primary circuits. The main circuit is mainly composed of rectifier circuit, current limiting circuit, filter circuit, braking circuit, inverter circuit and detection and sampling circuit. ...

Reynolds permanent magnet synchronous motor solutions Reynolds permanent magnet synchronous motor solutions

The permanent magnet synchronous motor has high-efficiency motor drive performance, which can complete high-speed, high-precision, high-stability, fast-responding, high-efficiency and energy-saving motion control. Reynolds drives provide a vector control technology solution for permanent magnet synchronous motors. ...

The heat dissipation method of the switching power supply The heat dissipation method of the switching power supply

1. Transfer heat pipes for heat dissipation. In many applications, heat generated from the base steel plate of the power module is transferred through the heat transfer components to the distant surface of the heat pipe. In this way, the temperature of the base steel plate of the power module will be equal to the temperature of the heat pipe heat dissipation surface, the temperature of the heat transfer parts, and the temperature of the two contact ...

The external configuration of the inverter is solved - Reynolds The external configuration of the inverter is solved - Reynolds

With the improvement of the degree of automation of packaging machinery, packaging machine inverter (hereinafter referred to as VFD) plays an increasingly important role in packaging machinery. Capsule filling machine, high-speed tablet press, bottling production line, aluminum-plastic packaging machine, cartoning machine, each equipment will use VFD, mainly ...

The relationship between Reynolds motion control and frequency converters The relationship between Reynolds motion control and frequency converters

Motion control has obvious period characteristics, it is a variety of high-tech generalization, used to push industrial automation, office automation and home automation to a higher stage. Nowadays, motion control is mainly composed of variable frequency drive (VFD), electric motor, control ...

Applicable mode of inverter maintenance - Reynolds inverter Applicable mode of inverter maintenance - Reynolds inverter

CNC cutting machine 1. Gradual reduction method The so-called gradual reduction method is to narrow the scope of shortcomings step by step by elaborating the shortcomings and judging the measurement parameters.

Advantages of frequency converters over soft start – Reynolds Advantages of frequency converters over soft start – Reynolds

(1) The starting torque is large and the power factor is high. Because the power factor of the motor is related to the working frequency, the power factor under the power frequency power supply is much lower than that under the low-frequency power supply when the motor is running at low speed. The inverter can control the motor from low frequencies and ...

The solution to the low or high output of the differential pressure transmitter – ifm The solution to the low or high output of the differential pressure transmitter – ifm

When the differential pressure flowmeter (V-cone flowmeter) is used in the field, it often encounters such and such problems, but the reason for it is investigated, as long as it is installed correctly, the primary problem is on the secondary surface differential pressure transmitter, and the following is the first to introduce these problems to us ...

Operating instructions for the Reynolds control panel Operating instructions for the Reynolds control panel

1. FUN button; Press the FUN button to enter the settings menu F00; 2. Press and hold the up button or down button to scroll to the code that needs to be set; 3. Press the FUN button to confirm at this moment, and adjust the entry parameters to the required value; 4. After the adjustment is completed, press the WR storage button, and then the panel will display the ...

Inverter maintenance power-on test instructions - Reynolds Inverter maintenance power-on test instructions - Reynolds

First, the inverter is not repaired and the power test is tested (1) Inverter repair test rectifier circuit At the two ends of the inverter to detect the internal DC power supply, P and N ends, adjust the multimeter to the resistance RX10 gear, the red watch pen is connected to the P end, and the black watch pen is connected to R, S, T, and there are tens of ohms under normal conditions.

Reynolds inverter E.oC3 constant speed operation overcurrent fault solution Reynolds inverter E.oC3 constant speed operation overcurrent fault solution

Reynolds inverter RNB1000 series E.oC3 constant speed operation overcurrent fault solution Reynolds inverter fault codes: E.oC3 Reynolds inverter fault phenomenon/type: Constant speed operation overcurrent Possible causes of Reynolds inverter failure: ...

Lightning protection measures for Reynolds frequency converters Lightning protection measures for Reynolds frequency converters

The lightning protection measures of the inverter equipment are another important peripheral measure to ensure the safe operation of the inverter, especially in the area where lightning is active or in the lively season, this problem is particularly important. Today's inverter products are generally equipped with mines.

Germany core control appeared at the China International Industry Fair Germany core control appeared at the China International Industry Fair

It is human beings who have always been committed to making human-computer interaction safer, easier to use, and more efficient, which has made collaborative robots gradually become the main stream of shopping malls. It is precisely because of the vigorous development of the collaborative robot industry that Synapticon Gmb ...

Reynolds inverter code function description Reynolds inverter code function description

F09 second acceleration time 0.10 - 999.9sec; 5.0sec; △ The first acceleration and deceleration parameters and the second acceleration and deceleration parameters are switched by terminal X3 (see F55); F10 second deceleration time 0.10 - 999.9sec; 5.0sec; △ The first acceleration and deceleration parameters and the second acceleration and deceleration parameters ...

Reynolds inverter parameter problem Reynolds inverter parameter problem

1. What are the factory recovery parameters of Reynolds inverter? N600 = 100 (often press the WR button for 3-5 seconds), it is necessary to be in the shutdown state to be effective. 2. In the parameters of the N308 motor of the inverter, is the [motor leakage inductance reactance] specified sub-leakage inductance or rotor leakage inductance react? Decide...

Reynolds drives RNB1000 series fault code resolution Reynolds drives RNB1000 series fault code resolution

Reynolds inverter fault codes: E.bC Reynolds inverter fault phenomenon/type: Brake unit failure   ​   Reynolds inverter failure may be caused: 1. Brake line failure or brake ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top