Reynolds permanent magnet synchronous motor solutions

Create Date: 2024-8-30 12:03:23|Source: RENLE/RENOLDS

The permanent magnet synchronous motor has high-efficiency motor drive performance, which can complete high-speed, high-precision, high-stability, fast-responding, high-efficiency and energy-saving motion control. Reynolds drives provide a vector control technology solution for permanent magnet synchronous motors.

                               Reynolds permanent magnet synchronous motor solutions

RNB1000F is a high-performance inverter that brings together Reynolds' vector inverter skills, which can drive both synchronous and asynchronous motors, while maintaining excellent basic performance and functionality, it can calmly face the skills and performance problems encountered in various occupations and equipment, and from the customer's point of view, there are significant improvements in the maintainability, ease of use, environmental protection, installation space and compliance with higher design standards.

The permanent magnet synchronous motor is driven in the form of vector control, so that the inverter can complete the low-frequency and large torque, high-efficiency grid voltage utilization rate and optimized sine wave output under the premise of minimum switching loss according to the user's process control requirements, so that the motor can reduce the working noise, reduce the heat generation, and reliably maintain the mechanical equipment. In the V/F control mode, the asynchronous motors can be driven together.
  ​
The products are widely used in electric power, metallurgy, petroleum and petrochemical, military industry, mining, chemical industry, construction, building materials, pharmaceutical, municipal, textile printing and dyeing, papermaking, rubber and plastics, rail transit, hydropower, aerospace science and technology, new energy batteries, semiconductors and other industrial occupations.

More on that
How to deal with the inlet water of the inverter - Reynolds How to deal with the inlet water of the inverter - Reynolds

Inverters are widely used in all walks of life, in a variety of applications, inverters will inevitably encounter rainy and humid climate, resulting in internal wetness, or accidentally into the water, in fact, as long as it is found in time, it can still be rescued. If it is in the unpowered state ...

Reynolds inverter manual Reynolds inverter manual

Reynolds inverter brochure (partial)   Before installing When unpacking, it is found that the machine has water or left water traces, indicating that the inverter has been flooded, so please do not install and use it. When unpacking, it is found that the machine is damaged and deformed or the parts are missing, please do not install and use it, otherwise there will be fault expansion and personnel ...

Classification of Reynolds inverter types Classification of Reynolds inverter types

1. Classified according to the input voltage level According to the input voltage level, the inverter can be divided into low-voltage inverter and high-voltage inverter, and the low-voltage inverter is common in China with single-phase 220 V inverter, three-phase 220 V inverter, and i-phase 380 V inverter. High-voltage inverters are commonly used in 6 kV, 10 kV transformers.

"RNB6000 frequency conversion governor" was included in the National Torch Program "RNB6000 frequency conversion governor" was included in the National Torch Program

Recently, in the "2012 National Torch Program Project" issued by the Ministry of Science and Technology of the People's Republic of China, the "RNB6000 Frequency Conversion Governor" independently developed by Reynolds was included in the "2012 National Torch Program Project" with its domestic leading skills and efficient energy-saving conversion power.

The inverter cannot adjust the frequency solution - Reynolds The inverter cannot adjust the frequency solution - Reynolds

1. The acceleration moment is too short. Theoretically, the longer the acceleration time, the stronger the load lifting capacity. If the acceleration time is set too short, some VFDs will show an overcurrent or overload, overtemperature alarm, while others will not, and will only be stuck in a certain frequency band. 2.The V/F ratio is too large Some of this ...

Classification and working principle of Reynolds inverter Classification and working principle of Reynolds inverter

Classification of Reynolds frequency converters: There are many classification methods for Reynolds inverters, which can be divided into voltage-type inverters and current-type inverters according to the classification of the main circuit operation method; According to the classification of switching methods, it can be divided into PAM operation.

Inverter control method - Reynolds Inverter control method - Reynolds

The output voltage of low-voltage general frequency conversion is 380-650V, the output power is 0.75-400kW, and the operating frequency is 0-400Hz. Its control methods have gone through the following four generations. 1U/f=C Sinusoidal Pulse Width Modulation (SPWM) Manipulation MethodIts Characteristics ...

The main failure mode of mechanical parts – Reynolds The main failure mode of mechanical parts – Reynolds

The top failure modes of mechanical parts: Failure: The mechanical part cannot complete its normal function within the planning and booking period and under the regular conditions. Ways in which mechanical parts fail: overall cracking, plastic deformation, corrosion, abrasion, gluing, and touch exhaustion General ...

Frequency conversion cabinet external conduit wiring method - Reynolds Frequency conversion cabinet external conduit wiring method - Reynolds

When it is required to wiring outside the frequency conversion cabinet, it is generally necessary to use the conduit for wiring, which requires suitable mechanical pressure and unsuitable mechanical damage, moisture-proof and corrosion-resistant. Conduits include the following two wiring methods: 1. Kim ...

Introduction and features of Reynolds soft starters Introduction and features of Reynolds soft starters

Reynolds soft starters include soft starters for high, medium and low voltage motors, including JJR1000 series, JJR2000 series, JJR5000 series, and RNB3000 series frequency converters. Reducing the starting power supply avoids voltage drops and voltage dips in the power supply. Smooth start-up avoids product damage. ...

Reynolds frequency converters are remotely controlled for wiring Reynolds frequency converters are remotely controlled for wiring

1. Connect X (switching input) drive terminal to control the inverter start-stop/positive rotation; 2. Connect to the AI (analog input) terminal to control the frequency of the inverter (perhaps made into PID closed-loop control automatic adjustment frequency) ​ 3. ...

Replacement of spare parts for frequency converters – Reynolds Replacement of spare parts for frequency converters – Reynolds

In order for a VFD to operate reliably for a long time, it is necessary to repair the electronic components in the VFD on a regular basis and replace the primary components of the VFD according to the service life. 1. Cooling fan The VFD power module is the most heat-generating device, and its ...

Precautions for installation of Reynolds low-voltage inverters Precautions for installation of Reynolds low-voltage inverters

One. Safety Precautions 1. First of all, it is necessary to have certain electrical professional knowledge, and understand the job site, understand the equipment status, and have certain electrical operation technology. 2. Determine the voltage level of the equipment (such as low-voltage AC380V) and whether it is low-voltage ...

The basic principle of vector control of frequency converters The basic principle of vector control of frequency converters

The basic principle of vector control is to control the excitation current and torque current of the asynchronous motor according to the principle of magnetic field orientation through the measurement and control of the stator current vector of the asynchronous motor, and then achieve the purpose of controlling the torque of the asynchronous motor. Specifically, the stator of the asynchronous motor ...

Key points for the selection of Reynolds servo motors Key points for the selection of Reynolds servo motors

Each type of servo motor has additional torque, maximum torque and servo motor inertia and other parameters in the standard items, each parameter and load torque and load inertia must have a relevant connection, the output torque of the servo motor should meet the requirements of the movement conditions of the load organization, such as the speed of the acceleration ...

Basic characteristics of inverter transmission - Reynolds Basic characteristics of inverter transmission - Reynolds

Compared with the motor driven by the inverter, the power factor and efficiency of the motor will deteriorate and the temperature rise will increase because the output waveform of the inverter contains the influence of higher harmonics. On the other hand, when the frequency conversion is driven, the same torque should be obtained as when the power frequency power supply is driven, ...

Parameter setting of acceleration and deceleration time of Reynolds universal inverter Parameter setting of acceleration and deceleration time of Reynolds universal inverter

The acceleration time of the Reynolds inverter is the time required for the output frequency to rise from 0 to the high frequency, and the deceleration time is the time required to decrease from the high frequency to 0. Generally, the frequency converter uses the frequency setting signal to rise and fall to confirm the acceleration and deceleration time. The rise of the frequency setting must be limited when the motor accelerates.

The inverter prepares the braking resistance factor – Reynolds The inverter prepares the braking resistance factor – Reynolds

The preparation of the braking resistor of the inverter is mainly to consume part of the energy on the DC bus capacitor through the braking resistor to avoid the capacitor voltage being too high. Theoretically, if the capacitor stores a large amount of energy, it can be used to release it to drive the motor and avoid energy waste. However, the capacitance of the capacitor is ...

Inverter acceleration and deceleration mode selection Inverter acceleration and deceleration mode selection

The selection of the acceleration form and deceleration form of the inverter is also called the selection of acceleration and deceleration curves. Generally, there are several forms of inverter, such as linear, S-shaped, semi-S-shaped, etc., and the characteristics and uses of each form are as follows. 1. Linear form The form makes the inverter ...

The basic principle of vector control – Reynolds frequency converters The basic principle of vector control – Reynolds frequency converters

The fundamental principle of vector control is to control the excitation current and torque current of the asynchronous motor according to the principle of magnetic field orientation through the measurement and control of the stator current vector of the asynchronous motor, and then to achieve the purpose of controlling the torque of the asynchronous motor. Specifically, it is to ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top