Lightning protection measures for Reynolds frequency converters

Create Date: 2024-8-30 12:03:23|Source: RENLE/RENOLDS

The lightning protection measures of the inverter equipment are another important peripheral measure to ensure the safe operation of the inverter, especially in the area where lightning is active or in the lively season, this problem is particularly important.

                               Lightning protection measures for Reynolds frequency converters

Today's inverter products are generally equipped with a lightning absorption network, which is mainly used to avoid damage to the inverter due to instantaneous lightning intrusion. However, in practice, especially in the case of overhead introduction of power lines, the lightning absorption network that comes with the inverter alone cannot meet the requirements, and it is also necessary to set up a special lightning arrester for the inverter. Specific measures include:

(1) A special surge arrester for frequency conversion can be installed at the power supply inlet (optional);

(2) Or according to the standard requirements, the embedded steel pipe is 20m away from the inverter for special grounding protection;

(3) If the power supply is imported by cable, the lightning protection system in the control room should be done to prevent lightning from entering and damaging the equipment.
More on that
Inverter starts the overload adjustment parameter - Reynolds Inverter starts the overload adjustment parameter - Reynolds

Motor overload: There is no need to set overload maintenance parameters in frequency conversion. The inverter generally acquiesces to the motor overload maintenance based on the motor power. Generally, it is 1.2 times and 60 seconds will report an overload failure. The overload factor is not the same for different frequency converters. ...

Operating instructions for the Reynolds control panel Operating instructions for the Reynolds control panel

1. FUN button; Press the FUN button to enter the settings menu F00; 2. Press and hold the up button or down button to scroll to the code that needs to be set; 3. Press the FUN button to confirm at this moment, and adjust the entry parameters to the required value; 4. After the adjustment is completed, press the WR storage button, and then the panel will display the ...

The breaking capacity of the industrial control appliance switch The breaking capacity of the industrial control appliance switch

Assuming Icu=60KA, then when a faulty current of 60KA is generated in the line, the circuit breaker can safely cut off the circuit without abnormal conditions such as contact welding and blasting. Pay attention to the extreme breaking ...

Germany core control appeared at the China International Industry Fair Germany core control appeared at the China International Industry Fair

It is human beings who have always been committed to making human-computer interaction safer, easier to use, and more efficient, which has made collaborative robots gradually become the main stream of shopping malls. It is precisely because of the vigorous development of the collaborative robot industry that Synapticon Gmb ...

Fault signal of the frequency converter - Reynolds frequency converter Fault signal of the frequency converter - Reynolds frequency converter

There are three types of fault signals for the inverter: (1) Excessive mechanical load: The primary feature of excessive load is that the motor heats up, and the operating current can be read from the display screen to find. The primary reason is that the load of the inverter is too large, and the acceleration and deceleration time and operation cycle time are too short; V/F ...

Two Reynolds technologies were included in the "2020 Water Conservancy Technology Key Promotion Catalogue" Two Reynolds technologies were included in the "2020 Water Conservancy Technology Key Promotion Catalogue"

In May 2020, Reynolds was recommended by relevant departments to apply for the Ministry of Water Resources's "2020 Key Promotion and Guidance Catalogue of Advanced and Practical Water Conservancy Technologies".

Inverter installation and heat dissipation treatment - Reynolds Inverter installation and heat dissipation treatment - Reynolds

The inverter has power loss during operation and converts it into heat energy, which increases its own temperature. Roughly speaking, the power loss of every 1kVA inverter capacity is about 40W-50W. Therefore, when installing the inverter, it is necessary to consider the heat dissipation of the inverter, and how to run the inverter.

Replacement of spare parts for frequency converters – Reynolds Replacement of spare parts for frequency converters – Reynolds

In order for a VFD to operate reliably for a long time, it is necessary to repair the electronic components in the VFD on a regular basis and replace the primary components of the VFD according to the service life. 1. Cooling fan The VFD power module is the most heat-generating device, and its ...

Wiring method and principle of PLC and inverter shielded wire - Reynolds Wiring method and principle of PLC and inverter shielded wire - Reynolds

In order to avoid the interference of the control signal line between the PLC and the inverter by the space electromagnetic field, the shielding wire can be connected to the outer layer of these control signal lines to improve the anti-interference ability of the system. This kind of wiring must be noted, and only one point can be selected for the grounding point of the shield. Whether it's on the PLC side, or ...

Wiring of the main circuit of the inverter - Reynolds Wiring of the main circuit of the inverter - Reynolds

(1) Inverter three-phase communication input terminal (R, S, T) The power input terminal is connected to the three-phase communication power supply through the circuit breaker of the circuit breaker for line protection, regardless of the connection phase sequence. It should be noted here that the three-phase communication power supply must not be directly connected to the inverter output ...

Characteristics and Discrimination of Resistance Damage - Reynolds Characteristics and Discrimination of Resistance Damage - Reynolds

I often see many beginners tossing on the resistor when overhauling the circuit, and it is dismantling and welding, in fact, it is repaired a lot, as long as you understand the damage characteristics of the resistor, you don't have to bother. Resistors are the most numerous in electrical equipment ...

Faulty inverter – Reynolds inverter Faulty inverter – Reynolds inverter

In ancient times, there were ten major tortures, which made people unable to survive and die, and experienced the purgatory of the world; Today, there are ten "tortures" of inverters, and the same can make your inverters suffer. Let's follow the editor to find out which of the top ten "tortures" will make your inverter "worse than dead"! ...

Frequency characteristics of Reynolds frequency converters Frequency characteristics of Reynolds frequency converters

a. Output frequency scale. The output frequency scale that can be controlled by the general inverter, the lowest starting frequency is generally 0.1Hz, and the highest frequency is different according to the functional indicators of the inverter, generally 400Hz, and some models are 650Hz. No matter how high the output frequency is, it depends on the scale of the high-frequency inverter. ...

The abnormal installation of the inverter in the power frequency motor leads to hazards The abnormal installation of the inverter in the power frequency motor leads to hazards

Installing a variable-frequency drive (VFD) on the power frequency motor can complete the precise control and speed regulation of the motor, and improve the power and accuracy of the progressive motor. However, if it is not properly used and used, the following damages may occur: ...

The cause of bearing noise in different situations of frequency converters - Reynolds The cause of bearing noise in different situations of frequency converters - Reynolds

1. If the bearing is in good continuous rotation condition, it will emit a low whining or humming sound. Sharp hissing, squeaking and other irregular sounds often indicate that the bearing is in a bad continuous rotation condition. The sharp squeaky noise can be due to the formation of an inappropriately smooth ...

The frequency of the frequency converter is given in a given way The frequency of the frequency converter is given in a given way

The first way to use the inverter is to change the output frequency to achieve the controllability of the motor speed, so do you know what steps to complete the output frequency controllability? One of the first and foremost key points is how to complete the change of the frequency signal supplied by the inverter equipment.

Applicable mode of inverter maintenance - Reynolds inverter Applicable mode of inverter maintenance - Reynolds inverter

CNC cutting machine 1. Gradual reduction method The so-called gradual reduction method is to narrow the scope of shortcomings step by step by elaborating the shortcomings and judging the measurement parameters.

Inverter replacement component requirements - Reynolds Inverter replacement component requirements - Reynolds

1) Find out the basic parameters and appearance of the equipment that needs to be replaced. The basic parameters include the rated operating current, the capacitance of the capacitor, the resistance value of the resistor, the value of the GTR Darlington device (current amplification factor), the switching characteristics and saturation voltage of the IGBT (including IPM) device, etc.

Frequency converter overcurrent problem treatment - Reynolds Frequency converter overcurrent problem treatment - Reynolds

General treatment methods for inverter overcurrent problems: The output side of the inverter is a PWM voltage waveform, and after passing through the motor winding, the output current is approximately a sine wave, and lags behind the voltage by a phase viewpoint, which is determined by the power factor of the motor. The output current of the inverter passes through ...

The difference between servo and inverter - Reynolds The difference between servo and inverter - Reynolds

Overload can be different Servo drives generally have 3 times the overload ability, which can be used to overcome the inertial moment of the inertial load at the moment of start-up, while the frequency converter generally allows 1.5 times the overload. Handling precision Servo control ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top