Input rated voltage, frequency 3 phase: 380V, 50/60Hz allowable scale Voltage: 320-420V;
Voltage unbalance: <3%;
Frequency: 47-63 Hz Output Output voltage 3 phases, 0V - input voltage, error less than 5% Output frequency scale 0.00-650.00Hz Overload to 110% rated current 1 minute Frequency resolution Number given: 0.01Hz; Imitation given: 0.1%*** large frequency Output frequency accuracy Imitation given: ±0.2%*** large frequency (25±10°C);
Digital given: 0.01Hz (-10-+40°C) Operation Command Channel The operation panel is given, the control terminal is given, and the communication is given, and the frequency can be switched through the terminal Frequency Given Channel Operation Panel, Communication, UP/DOWN Conditioning Value, AI1, AI2, AI3, PFI Auxiliary frequency given Complete sensitive auxiliary frequency fine-tuning, given frequency synthesis Torque Improvement Active torque increase, manual torque increase V/F curve User-defined V/F curves, linear V/F curves, and 5 Characteristic curve of torque reduction Jog Jog Frequency Scale: 0.10-50.00Hz;
Jog acceleration and deceleration time: 0.1 - 60.0s Active energy-saving operation According to the load situation, actively optimize the V/F curve to complete the active energy-saving operation Active Voltage Adjustment (AVR) When the grid voltage changes within a certain scale, it can actively keep the output voltage constant Active carrier adjustment The carrier frequency can be actively adjusted according to the load characteristics and ambient temperature Random PWM adjusts the timbre of the motor when it is running Instantaneous stop processing When the power is instantaneous, it is controlled by the bus voltage to complete uninterrupted operation DC braking ability Braking time: 0.0-60.0s, braking current: 0.0-100.0% rated current PFI *** High input frequency: 50kHz PFO 0-50kHz open-collector type pulse square wave signal output, programmable analog input 3 analog signal inputs, voltage type current type are optional, positive and negative input analog output 2 analog signal outputs, 0/4-20mA or 0/2-10V, programmable digital input 8 multi-function digital inputs Digital output: 2 multi-function open-collector outputs, 5 multi-function relay outputs Communication Built-in RS485 communication interface, support Modbus protocol, USS command.
Featured Functions:
Process PID Two sets of PID parameters, a variety of correction modes Water supply function A variety of water supply modes: fire control, water injection control, clear water pool detection, sewage pool detection and sewage pump control, dormant operation, punctual pump change, pump maintenance, etc.
User-defined menus
30 user parameters can be defined Changing the Parameter Display The parameters that support different from the factory value are displayed
Chronograph watt-hour meter function
Easy to adjust the best energy-saving plan Protection function Overcurrent, overvoltage, undervoltage, input and output phase loss, output short circuit, overheating, motor overload, external fault, imitation input drop, stall avoidance, etc.
Options
Brake components, operation panel extension cable, remote control box, digital I/O expansion board, relay expansion board, operation panel with parameter replication function (SB-PU70E), Chinese and English LCD display operation panel (SB-PU04), etc.
Environmental application site
The altitude is less than 1000 meters, indoor, not exposed to direct sunlight, no dust, corrosive gas, flammable gas, oil mist, water vapor, dripping, salt spray and other occasions.
Operating Ambient Temperature/Humidity -10--+40°C/<90%RH, no condensation of water droplets Storage Temperature ——20-+60°C Vibration Less than 5.9m/s2 (0.6g)
Degree of protection IP20 Cooling method Forced air cooling, with electric fan control
|
More on that
|
How to carry out frequency conversion of frequency converter - Senlan
(1) Rectifier. As one of the most important components of the inverter, the rectifier can convert the AC power into direct current. Its working method is more common to that of a battery charger or arc welder. It uses a diode bridge to limit the communication sine wave to only one direction.
|
|
The method of selecting the appropriate peripheral equipment for the inverter - Senland
When we have selected a suitable Variable-frequency Drive (VFD), we also need to consider whether we need to equip other peripheral equipment according to the actual situation of the site. The peripheral equipment selected by VFD mainly includes circuit breakers, reactors, contactors, braking resistors, etc.
...
|
|
Ensure the normal operation of the inverter in a humid environment
Due to the heavy rain and humidity in some areas recently, in order to avoid long-term power failure and the impact of wetting on the inverter, the following points can be used as various precautions before customers resume production:
1. Look inside the electrical cabinet, e.g. ...
|
|
Common maintenance methods of inverter - Senlan inverter
1. Step-by-step decreasing method
The so-called gradual reduction method is to gradually reduce the scale of the problem through the analysis of the problem phenomenon and the identification of measurement parameters, and finally implement it to the specific circuit or component that causes the problem. In essence, it is a certainty, a negation, a negation, a negation, a final ...
|
|
The cause of vibration and noise in the inverter - Sunland inverter
Generally speaking, the inverter will inevitably present some problems during operation, such as oscillation and noise, which are common problems in VFD operations. So, what causes oscillation and noise in VFDs? What is the solution to these problems? Here are the causes of VFD oscillation and noise ...
|
|
Motor encoder and rotor pole phase zero alignment repair - Sunland
1. Phase alignment method of incremental encoder
The alignment between the phase of the UVW electronic transmutation signal and the phase of the rotor pole, or the phase of the TV spot, of the incremental encoder with the signal exchange is as follows:
1) Use a DC power supply to pass the UV winding of the motor to less than the amount of ...
|
|
Suppression method of electromagnetic interference of inverter - Sunland inverter
The operating principle of the inverter determines that it will have a certain disturbance, which may bring EMC (electromagnetic compatibility) problems to the equipment or system, and the inverter, as an electronic device, will also be affected by external electromagnetic disturbance.
Below...
|
|
Inverter classification method - Senlan inverter
1. Classified according to the input voltage level
According to the input voltage level, the inverter can be divided into low-voltage inverter and high-voltage inverter, and the low-voltage inverter is common in China with single-phase 220 V inverter, three-phase 220 V inverter, and i-phase 380 V inverter. High-voltage inverters are commonly used in 6 kV, 10 kV transformers.
|
|
Inverter overcurrent protection solution - Senlan
1. Causes of overcurrent
There are many reasons for the occurrence of overcurrent, including soft and hard problems.
1. Causes of soft failures
When the acceleration or deceleration time in the inverter parameters is set too short, and the motor power is heavy, it means that in the acceleration, the inverter's ...
|
|
Motor starting mode - Senlan inverter
The inverter is a motor control (speed regulation) device that uses the on-off effect of power semiconductor devices to convert the power frequency power supply to another frequency.
Composition 1:
1. Rectifier unit: convert the communication electricity with fixed operating frequency into DC ...
|
|
The eight forbidden areas of inverter control loop wiring - Senlan
1. The wires of the inverter control circuit should be strictly distinguished from the main circuit cable (power line) and placed separately. This will help prevent the inverter's control circuit from being disturbed by harmonics in the inverter's main circuit.
2. To separate the connection of the inverter from the terminals or contacts of other control circuits, ...
|
|
Asynchronous motor with inverter method - Senlan
Before the asynchronous motor is equipped with an inverter, let's take a look at the three major types of mechanical equipment loads:
1. Constant torque load: such as conveyor belt and mixer; When the inverter drags the load of constant torque nature, the torque at low speed should be large enough, and the overload should be large enough. If you need ...
|
|
Anti-interference measures in the application of Sunland inverter
The main manifestations of the disturbance of the inverter in the application are: higher harmonics, noise and oscillation, load matching, heat generation and other problems. These disturbances are unavoidable, because the input part of the inverter is a rectifier circuit and the output part is an inverter circuit, both of which are made up of nonlinear components that play a switching effect.
|
|
Sunland - inverter operation process and factory value restoration
The general operation process is as follows:
Enter the program through the operation panel and set the parameters, and set the relevant parameter groups such as the start-stop method, operation and control form according to the requirements of the industrial control. After confirming that the wiring is correct, the no-load power on test run and ...
|
|
Precautions for the selection of exhaust fan inverter - Senlan
1. Whether it has perfect maintenance function
There will be many problems in the production process of the equipment, and if you want to prevent accidents, the equipment must have a perfect maintenance function, so as to prevent the loss of the enterprise. Therefore, when buying an exhaust fan inverter, you need to understand the safety function of the equipment first.
|
|
EMC rules for inverters - Sunland inverters
When various factory equipment uses frequency conversion speed regulation, harmonic disturbance will occur on the power supply side and motor side of the inverter (VFD), which will form electromagnetic disturbance to the power supply network and other electrical equipment near the VFD. In addition, in order to ensure the long-term reliable operation of the VFD, the wiring of the VFD is very important.
...
|
|
At the physical level, the stable operation of the inverter is guaranteed-Senlan inverter
For the most popular electrical control equipment inverter (Variable-frequency Drive, VFD), as a precision electronic industrial control equipment, in order to run smoothly for a long time, we, as professional and technical personnel, need to be on the VFD device or before the operation.
|
|
Inverter parameter setting - Sunland inverter
There are many setting parameters of the inverter, each parameter has a certain selection scale, and the inverter can not work normally due to the improper setting of individual parameters in use, so it is necessary to set the relevant parameters correctly.
...
|
|
Inverter control method for motor - Senlan
1. U/f stable control
U/f control is to change the voltage of the motor power supply together with changing the frequency of the motor power supply, so that the magnetic flux of the motor is kept constant, and the efficiency and power factor of the motor do not decrease within a wide range of speed regulation. Because it is to control the voltage and frequency ...
|
|
Analysis of Sunland inverter fault anomaly
|
|