The general operation process is as follows:

                                 Sunland - inverter operation process and factory value restoration

Enter the program through the operation panel and set the parameters, and set the relevant parameter groups such as the start-stop method, operation and control form according to the requirements of the industrial control. After confirming that the wiring is correct, power on the no-load test run and use the appearance to confirm that the input and output are normal. Finally, the load is connected and the operation is detected.

Factory Restore Value:

Same as above, enter the program to adjust the parameters to reset, and restore the factory settings. Note that the original parameters are recorded, so that the parameters can be corrected after resetting.
More on that
Inverter with no-load operation and commissioning - Senlan Inverter with no-load operation and commissioning - Senlan

(1) Set the power of the motor, the number of pole pairs, and check the operating current of the inverter. (2) Set the maximum output frequency and base frequency of the inverter and set the torque characteristics of the motor. Pressure/Frequency (V/F) Operators ...

The difference between "braking" and "parking" of the inverter - Senlan The difference between "braking" and "parking" of the inverter - Senlan

There are two ways to park a drive. One way is called "free parking". It is to quickly "power off" the motor, so that the motor can slide and park by its own inertia force (OFF2 parking); The other way is called "braking parking". So this "brake parking ...

Industrial control circuit board capacitor damage fault characteristics and maintenance - Senlan Industrial control circuit board capacitor damage fault characteristics and maintenance - Senlan

Capacitor damage is the highest problem in electronic devices, especially electrolytic capacitors. Capacitor damage is manifested in: 1. Capacity becomes smaller, 2. Capacity is completely lost, 3. Leakage, 4. Short circuit. Electricity...

The drive panel does not display fault analysis The drive panel does not display fault analysis

1. The rectifier module is damaged It is usually caused by grid voltage or internal short circuit. In the case of excluding internal short circuits, the rectifier bridge is replaced. 2. The inverter module is damaged It is usually caused by damage to the motor or cable and the failure of the drive circuit. After repairing the drive circuit, ...

Control the hovering function operation and principle of the inverter - Sunland inverter Control the hovering function operation and principle of the inverter - Sunland inverter

How does the hovering function of the inverter work? When the speed of the asynchronous motor is 0, the encoder response is meaningless, and it needs to be converted to V/F control, and the frequency is set to 0; The voltage is set to 0 speed at which the motor promises to withstand the current at the moment ...

According to the load characteristics, choose the inverter - Senland According to the load characteristics, choose the inverter - Senland

The types of production machinery are complex, the functional and process requirements are different, and the torque characteristics are also different, therefore, before the application of the inverter, the first thing is to understand the nature of the load carried by the motor, that is, the load characteristics, and then select the inverter and the motor. There are three types of loads: ...

Common maintenance methods of inverter - Senlan inverter Common maintenance methods of inverter - Senlan inverter

1. Step-by-step decreasing method The so-called gradual reduction method is to gradually reduce the scale of the problem through the analysis of the problem phenomenon and the identification of measurement parameters, and finally implement it to the specific circuit or component that causes the problem. In essence, it is a certainty, a negation, a negation, a negation, a final ...

Precautions for inverter selection and capacity matching - Senlan Precautions for inverter selection and capacity matching - Senlan

1. Select the inverter according to the load characteristics Second, when selecting the inverter, the current value of the practical motor should be used as the basis for the selection of the inverter, and the rated power of the motor can only be used as a reference. Secondly, it should be fully considered that the output of the inverter contains higher harmonics, which will form the power factor of the motor.

Inverter selection according to capacity matching - Senlan Inverter selection according to capacity matching - Senlan

We need to ensure that the capacity of the inverter is matched. First of all, according to the nature of the load, the correct type of inverter is selected. The general principle is what nature of the load characteristics with what characteristics of the inverter. (1) Constant torque production equipment - in the speed regulation range ...

The inverter is regularly replaced with the device - Sunland inverter The inverter is regularly replaced with the device - Sunland inverter

1. Cooling fan As a prerequisite for ensuring the normal operation of the inverter, efficient and fast in-line cooling fans have become an indispensable conversion configuration of the inverter. Because of the wear of the internal bearings of the cooling fan and the reduction of the grease function in the process of application, the cooling of the fan.

The inverter's requirements for the surrounding environment - Senlan The inverter's requirements for the surrounding environment - Senlan

1) Operating temperature: The inverter is a high-power electronic component, which is simply affected by the operating temperature, and the general temperature requirement is 0 - 55. However, in order to ensure the safety and reliability of the operation, it is necessary to consider freeing up space when using, and it is best to control it below 40. The inverter generally requires the device to operate ...

How to choose an inverter - Hope Sunland How to choose an inverter - Hope Sunland

The selection of the inverter should be considered according to the type of controlled object, speed regulation scale, static speed accuracy, starting torque, etc., so that it can be easy to use and economical together with meeting the process and production requirements. According to the different forms of devices, it can be divided into four types, which can be divided into four types according to the controlled motor power and field device ...

Hope Sunland launched the new Hope800 series inverter Hope Sunland launched the new Hope800 series inverter

Hope Sunland Technology Co., Ltd. is a national key high-tech enterprise dedicated to the research and development of high, medium and low voltage frequency conversion technology and the design, development, production, sales and service of related products.

The manufacturing standard of Sunland inverter cabinet The manufacturing standard of Sunland inverter cabinet

Planning specifications: The planning of inverter cabinets should conform to relevant national norms and industry norms, such as GB/T15576-2018 "Low-voltage Distribution Cabinet", GB7251.1-2017 "Low-voltage Complete Switchgear and Control Equipment", etc. Material specifications: The materials of the control cabinet should conform to the relevant codes and regulations.

Whether the front end of the inverter can be installed with a motor protector - Senlan Whether the front end of the inverter can be installed with a motor protector - Senlan

Frequency conversion speed regulation motor is generally selected 4-level motor, the fundamental frequency operation point is planned at 50Hz, the frequency 0-50Hz (speed 0-1480r/min) scale of the motor for constant torque work, the frequency of 50-100Hz (speed 1480-2800r/min) scale of the motor for constant power work, the whole speed regulation scale of (0 ...

Wiring specification of inverter control cabinet - Senland Wiring specification of inverter control cabinet - Senland

The signal line and the power line must be routed separately: when using the analog signal to remotely control the inverter, the signal line of the control inverter and the strong current circuit (main circuit and sequential control circuit) can be separated from the inverter and other equipment to the analog interference, and the interval should be more than 30cm. Signal ...

Inverter-related knowledge - Senlan inverter Inverter-related knowledge - Senlan inverter

1. What does open-loop mean in the use of inverters? The speed detector (PG) is installed on the motor equipment in operation, and the speed response of the actual speed is sent to the control equipment, which is called "closed loop", and the speed detector that does not use PG is called "open loop". Most general-purpose drives are open-loop ...

Sunland inverter helps the green development of non-ferrous metal mining Sunland inverter helps the green development of non-ferrous metal mining

From October 28th to 29th, the "First National Tailings Engineering and Comprehensive Utilization Skills Seminar" sponsored by the China Nonferrous Metals Society was successfully held in Dexing City, Jiangxi Province. From China Nonferrous Metals Society, China ENFI, Jiangxi Copper, Beijing Institute of Mining and Metallurgy, University of Science and Technology Beijing and other countries...

How far apart is the motor from the inverter - Senlan inverter How far apart is the motor from the inverter - Senlan inverter

The supplier of the supporting equipment of the inverter reminds you that the voltage waveform output by the inverter is similar to a sine wave, but not a real sine wave. Its waveform contains a large number of harmonic components, especially the higher harmonics will increase the output current of the inverter, causing the motor winding to heat up, and produce oscillation.

Sunland's measures to reduce inverter failure Sunland's measures to reduce inverter failure

According to the test, the service life of the inverter is halved for every 10°C increase in the operating ambient temperature. For this reason, in daily use, a reasonable maintenance cycle and guidelines should be formulated according to the actual operating environment and load characteristics of the inverter.

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top