Inverter parameter setting - Sunland inverter

Create Date: 2024-8-30 12:03:23|Source: Hope Sunland

There are many setting parameters of the inverter, each parameter has a certain selection scale, and the inverter can not work normally due to the improper setting of individual parameters in use, so it is necessary to set the relevant parameters correctly.

                                  Inverter parameter setting - Sunland inverter

1. Control method: that is, speed control, rotation control, PID control or other methods. After the control method is adopted, it is generally necessary to carry out static or dynamic identification according to the control accuracy.

2. Minimum operating frequency: that is, the minimum speed of motor operation, when the motor is running at low speed, its heat dissipation performance is very poor, and the motor will run at low speed for a long time, which will lead to motor incineration. In addition, at low speeds, the current in the cable will also increase, which will also cause the cable to heat up.

3. Maximum operating frequency: the maximum frequency of the general inverter is 60Hz, and some even to 400 Hz, the high frequency will make the motor run at high speed, which is for the general motor, its bearing can not run at extra speed for a long time, whether the rotor of the motor can accept such centrifugal force.

4. Carrier frequency: the higher the carrier frequency is set, the larger the higher harmonic component, which is closely related to the length of the cable, the heating of the motor, the heating of the cable and the heating of the inverter.

5. Motor parameters: The inverter sets the power, current, voltage, speed and maximum frequency of the motor in the parameters, and these parameters can be directly obtained from the motor nameplate.

6. Frequency hopping: at a certain frequency point, there may be resonance phenomenon, especially when the whole equipment is relatively high; When operating the compressor, avoid the surge point of the compressor.

More on that
Motor inspection and maintenance, motor problems - Senlan Motor inspection and maintenance, motor problems - Senlan

1: In the operation of the motor, if dust, water stains and other debris enter its interior, it will constitute a short-circuit medium, which can damage the wire insulation layer, form an inter-turn short circuit, increase the current, increase the temperature and incinerate the motor. Therefore, dust, water stains and other debris should be prevented from entering the motor.

Hope Sunland inverter fault code Hope Sunland inverter fault code

Hope Sunland inverter part of the fault code Er.ocb (1) Overcurrent at the moment of starting: There is a short circuit inside the motor There is a short circuit in the motor wiring The starting voltage is too high Check the motor and wiring Check the motor wiring Seek service Check the torque ...

Sunland won the "well-known brand of China's domestic inverter" for the fifth time in a row Sunland won the "well-known brand of China's domestic inverter" for the fifth time in a row

On April 15, 2011, the "Century Tour of China's Automation Industry (CAIE2011)" was held in Beijing, and Sunland inverter was once again re-elected as "China's well-known brand of domestic inverter". Dr. Chen Bin, President of Continental Hope Group and Chairman of Hope Sunland Technology Co., Ltd., personally ...

Analysis of Sunland inverter fault anomaly Analysis of Sunland inverter fault anomaly

The comprehensive application of Sunland's high-power boiler feed pump has added another classic The comprehensive application of Sunland's high-power boiler feed pump has added another classic

Recently, the "General Contracting Project of Boiler Feed Pump Frequency Conversion Technology Transformation Project of Yili Power Plant of Guoshen Group" undertaken by Hope Sunland has been successfully implemented and connected to the grid, adding another classic to the comprehensive application of Sunland's high-power boiler feed pump. In 2020 ...

Causes and solutions of inverter skipping current faults - Senlan Causes and solutions of inverter skipping current faults - Senlan

1. There is a short circuit to the ground in the output circuit of the inverter, you can check whether the wiring is correct and troubleshoot 2. If the motor parameters are incorrect, you can check the parameter settings and identify the parameters 3. The acceleration time is too short, and the acceleration time can be increased.

Inverter control method for motor - Senlan Inverter control method for motor - Senlan

1. U/f stable control U/f control is to change the voltage of the motor power supply together with changing the frequency of the motor power supply, so that the magnetic flux of the motor is kept constant, and the efficiency and power factor of the motor do not decrease within a wide range of speed regulation. Because it is to control the voltage and frequency ...

The correct wiring of the rail power supply The correct wiring of the rail power supply

The rail-rail power supply is a kind of switching power supply that is installed through the rail-type device, which is mainly used to monitor the voltage, current, temperature and other different aspects of the equipment, so that it can play a good maintenance effect. This switching power supply has a variety of different characteristics such as small size and light weight, ...

Motor encoder and rotor pole phase zero alignment repair - Sunland Motor encoder and rotor pole phase zero alignment repair - Sunland

1. Phase alignment method of incremental encoder The alignment between the phase of the UVW electronic transmutation signal and the phase of the rotor pole, or the phase of the TV spot, of the incremental encoder with the signal exchange is as follows: 1) Use a DC power supply to pass the UV winding of the motor to less than the amount of ...

Inverter classification method - Senlan inverter Inverter classification method - Senlan inverter

1. Classified according to the input voltage level According to the input voltage level, the inverter can be divided into low-voltage inverter and high-voltage inverter, and the low-voltage inverter is common in China with single-phase 220 V inverter, three-phase 220 V inverter, and i-phase 380 V inverter. High-voltage inverters are commonly used in 6 kV, 10 kV transformers.

Industrial control circuit board capacitor damage fault characteristics and maintenance - Senlan Industrial control circuit board capacitor damage fault characteristics and maintenance - Senlan

Capacitor damage is the highest problem in electronic devices, especially electrolytic capacitors. Capacitor damage is manifested in: 1. Capacity becomes smaller, 2. Capacity is completely lost, 3. Leakage, 4. Short circuit. Electricity...

Common brand inverter modification power method - Senlan inverter Common brand inverter modification power method - Senlan inverter

What are the advantages of inverter power correction? Many brands of inverter power boards, driver boards, and motherboards can be universal, as long as the type, volume, and hardware are the same, and the desired power and voltage value can be obtained by correcting the manufacturer's parameters. ...

Inverter with no-load operation and commissioning - Senlan Inverter with no-load operation and commissioning - Senlan

(1) Set the power of the motor, the number of pole pairs, and check the operating current of the inverter. (2) Set the maximum output frequency and base frequency of the inverter and set the torque characteristics of the motor. Pressure/Frequency (V/F) Operators ...

How to choose an inverter - Hope Sunland How to choose an inverter - Hope Sunland

The selection of the inverter should be considered according to the type of controlled object, speed regulation scale, static speed accuracy, starting torque, etc., so that it can be easy to use and economical together with meeting the process and production requirements. According to the different forms of devices, it can be divided into four types, which can be divided into four types according to the controlled motor power and field device ...

Senlan low-voltage inverter has four series of applications Senlan low-voltage inverter has four series of applications

1.SB200 fan pump special inverter, widely used in textile, printing and dyeing, washing, cable, packaging, machinery, ceramics, constant pressure water supply, constant temperature control or various OEM. 2.HG1000 high-performance light-load intelligent inverter ...

Failure of robot contactor and inverter - Senland Failure of robot contactor and inverter - Senland

Robot contactors are noisy? Cause: It is likely that the joint contact surface of the contactor is uneven, and the surface is sand or rust. The result will constitute a phase loss, which will lead to the burnout of contactors, switch frequency conversion and other components. Solution: will control the ...

Causes and treatment methods of inverter inverter module damage - Senlan Causes and treatment methods of inverter inverter module damage - Senlan

Most of the damage of the inverter module is due to the damage of the driving electric, which causes the two switching devices on one bridge arm to be turned on at the same time. Inverter inverter power module damage is a common problem in other inverter equipment such as vector inverter or energy-saving inverter.

Can the lower end of the leakage switch be connected to the inverter - Senlan Can the lower end of the leakage switch be connected to the inverter - Senlan

To be able to connect, you must use larger special specifications, the inverter outputs higher harmonics, and the leakage current is larger than that of conventional leakage switches, which simply trip, and requires the use of large-scale or special types of leakage switches. Many VFD manuals have instructions on the installation and selection of leakage switches.

What is the fault of the hope Sunland inverter Er0UE? What is the fault of the hope Sunland inverter Er0UE?

ER. The meaning of the OUE fault code is: overvoltage during standby. The possible reasons are: 1. DC bus voltage detection circuit failure; 2. The input voltage is abnormal or the power is lost during operation. It can detect whether the power supply voltage used by the inverter is normal, and in addition, it is necessary to check whether the power supply line of the inverter is ...

Sunland inverter braking resistor connection Sunland inverter braking resistor connection

Assuming that the inverter has a built-in braking unit and additional braking resistors, it is important to pay attention to the correct wiring of the braking resistors. The braking resistor should be connected between the P terminal and the DB terminal, but not between the P terminal and the N terminal, otherwise the three-phase rectifier bridge will operate at full load when it is not working, resulting in the equipment being unable to ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top