The method of selecting the appropriate peripheral equipment for the inverter - Senland

Create Date: 2024-8-30 12:03:23|Source: Hope Sunland

When we have selected a suitable Variable-frequency Drive (VFD), we also need to consider whether we need to equip other peripheral equipment according to the actual situation of the site. The peripheral equipment selected by VFD mainly includes circuit breakers, reactors, contactors, braking resistors, etc.

                              The method of selecting the appropriate peripheral equipment for the inverter - Senland

1. Circuit breaker

This circuit breaker can conveniently control the power off and closing of the circuit. It is mainly used to automatically block the power supply when the frequency conversion system presents reverse current, overcurrent, short circuit, and undervoltage, so as to play a blocking role and maintain the power supply.

2. Electrical interference equipment

Reactor is a common peripheral device in frequency conversion selection. When the VFD is too far away from the motor or the VFD is too close to the power supply, in order to improve the power factor and minimize the inrush current at the input terminal, a DC reactor or AC reactor must be added when selecting the VFD.

3. Current contactor

Contactors are divided into input contactors and output contactors. When a certain part of the frequency conversion system is faulty, the power supply will be automatically blocked to avoid the equipment burning out from a distance.

4. Braking resistance

When VFD is applied to inertial loads such as CNC machine tools and elevators, the selection of VFD requires the use of braking resistors to consume the excess energy generated in the frequency conversion system.

More on that
Practical installation precautions for frequency converters Practical installation precautions for frequency converters

When the line power supply exceeds the driver's kV-A rating by 10 times, add a line reactor. A 3% impedance line reactor should be used to reduce power line transient voltages caused by capacitor switching, line notching, DC bus overvoltage tripping, and inverter overcurrent and overvoltage conditions. Line...

Misunderstandings and countermeasures of industrial control inverter - Senlan Misunderstandings and countermeasures of industrial control inverter - Senlan

Today, with the rapid development of science and technology, with the continuous improvement of industrial automation, inverters have also been widely used. Choosing a suitable inverter is very important to ensure the normal and efficient work of the inverter, but in practice, it is necessary to pay attention to some ...

Inverter overcurrent protection solution - Senlan Inverter overcurrent protection solution - Senlan

1. Causes of overcurrent There are many reasons for the occurrence of overcurrent, including soft and hard problems. 1. Causes of soft failures When the acceleration or deceleration time in the inverter parameters is set too short, and the motor power is heavy, it means that in the acceleration, the inverter's ...

Get to know the capacitor of the inverter - Sunland inverter Get to know the capacitor of the inverter - Sunland inverter

1. The capacitance is generally indicated by "C" plus a number in the circuit (e.g., C25 indicates the capacitance numbered 25). A capacitor is a component composed of two metal films close to each other and separated by an insulating material in the center. The characteristic of the capacitor is first and foremost the communication through the DC block. The size of the capacitance is ...

Inverter water inlet maintenance method - Sunland inverter Inverter water inlet maintenance method - Sunland inverter

The first step is not to turn on electricity! First open the inverter panel, wipe the inverter dry, and then use a hair dryer to dry the display, PC board, push board, power components, fans, etc., with 95% alcohol, scrub the components with 95% alcohol, and dry the hair dryer with cold air. Step 2: After an hour, use alcohol ...

Hope Senlan inverter control panel button function diagram Hope Senlan inverter control panel button function diagram

Hope Senlan inverter control panel button function diagram 1. The "FUNC/DATA" button is a programming key, press this button once to convert the operation mode, and press it again to read and write the utility code. 2."S ...

Limit switch wiring method - hope Senlan Limit switch wiring method - hope Senlan

Limit switch is an electromechanical control element used to detect the direction of the movement of the machine or equipment, and send a signal when the specific position is in a specific direction to control the operation or stop of the equipment. It is often used in industrial production processes, such as CNC machine tools, conveyors, loading and unloading robots, etc. ...

Learn the way of inverter - Senlan inverter Learn the way of inverter - Senlan inverter

The inverter is an essential accessory in industrial use, and its main function is to regulate the speed of the motor. It is widely used in various equipment such as production F-line and machine tools. Many engineering people have touches. The functions of the inverter are many, the parameters are complex, and it is difficult to play without professionals. ...

Inverter super password summary Inverter super password summary

1. Delta's super password-B series: 57522; - H-series: 33582; S1 series inverter universal password: 575222. Second, Huifeng inverter (that is, now Ou Rui inverter), the general super password of its products is: 18881500-G 1500-P 1000- ...

Effect of inrush current on inverter - Senlan Effect of inrush current on inverter - Senlan

In the process of repairing the inverter, we can find that because of the back electromotive force in the stator winding, the electromotive force in the synchronous generator state and the self-induced electromotive force in the self-loop rotor, the current impact will inevitably have a negative impact on the motor, the inverter (Variable-frequency ...

The eight forbidden areas of inverter control loop wiring - Senlan The eight forbidden areas of inverter control loop wiring - Senlan

1. The wires of the inverter control circuit should be strictly distinguished from the main circuit cable (power line) and placed separately. This will help prevent the inverter's control circuit from being disturbed by harmonics in the inverter's main circuit. 2. To separate the connection of the inverter from the terminals or contacts of other control circuits, ...

A contactor is used between the inverter and the motor - Senlan inverter A contactor is used between the inverter and the motor - Senlan inverter

Whether a contactor is used between the inverter (VFD) and the motor depends on the specific situation. When the contactor is on and off when the motor is running, the operating overvoltage is easy to cause VFD damage. Therefore, whether to use the contactor, it must be based on the actual situation to make the correct ...

Motor inspection and maintenance, motor problems - Senlan Motor inspection and maintenance, motor problems - Senlan

1: In the operation of the motor, if dust, water stains and other debris enter its interior, it will constitute a short-circuit medium, which can damage the wire insulation layer, form an inter-turn short circuit, increase the current, increase the temperature and incinerate the motor. Therefore, dust, water stains and other debris should be prevented from entering the motor.

The inverter is regularly replaced with the device - Sunland inverter The inverter is regularly replaced with the device - Sunland inverter

1. Cooling fan As a prerequisite for ensuring the normal operation of the inverter, efficient and fast in-line cooling fans have become an indispensable conversion configuration of the inverter. Because of the wear of the internal bearings of the cooling fan and the reduction of the grease function in the process of application, the cooling of the fan.

Ensure the normal operation of the inverter in a humid environment Ensure the normal operation of the inverter in a humid environment

Due to the heavy rain and humidity in some areas recently, in order to avoid long-term power failure and the impact of wetting on the inverter, the following points can be used as various precautions before customers resume production: 1. Look inside the electrical cabinet, e.g. ...

I/O (Input/Output) Selection – Senland I/O (Input/Output) Selection – Senland

In the 90s of the 20th century, PLC has formed a variety of PLCs: micro, small, medium, large and giant. According to the number of I/O points, it can be divided into five types: micro PLC (32 I/O), small PLC (256 I/O), medium PLC (1024 I/O), large PLC (4.69 I/O), and giant PLC (8195 I/O). ...

Inverter device inspection and maintenance work steps Inverter device inspection and maintenance work steps

1. Preparation process: Abort the device and admit that the motor is completely aborted. Press the stop button on the operator panel to stop the operation. Disconnect the external mains power supply (low-voltage cabinet drawer). Adequate security treatment should be carried out to ensure that it is indeed disconnected and that it does not ...

How far apart is the motor from the inverter - Senlan inverter How far apart is the motor from the inverter - Senlan inverter

The supplier of the supporting equipment of the inverter reminds you that the voltage waveform output by the inverter is similar to a sine wave, but not a real sine wave. Its waveform contains a large number of harmonic components, especially the higher harmonics will increase the output current of the inverter, causing the motor winding to heat up, and produce oscillation.

Sunland attended the 2015 Industrial Automation Exhibition in Nuremberg, Germany Sunland attended the 2015 Industrial Automation Exhibition in Nuremberg, Germany

November 24, 2015 - November 26, 2015, "Germany Nuremberg Industrial Automation Exhibition" was successfully carried out at the Nuremberg International Exhibition Center in Germany, and it is expected that Sunland as a domestic professional inverter manufacturer also participated in the exhibition, in this exhibition, in addition to the usual SB70, ...

Sunland inverter does not show fault repair Sunland inverter does not show fault repair

After inspection, the circuit board of the machine is composed of a fan switching power supply board, a control board with a switching power supply and a driving board, etc., the fan power supply and the control board operation power supply are independent of each other, the fan power supply output is normal, and the control board operation power supply is not output due to the problem. ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top