Ensure the normal operation of the inverter in a humid environment

Create Date: 2024-8-30 12:03:23|Source: Hope Sunland

Due to the heavy rain and humidity in some areas recently, in order to avoid long-term power failure and the impact of wetting on the inverter, the following points can be used as various precautions before customers resume production:

                               Ensure the normal operation of the inverter in a humid environment

1. Look inside the electrical cabinet, for example, to see if there are small animals and their droppings, and whether there are condensation or water marks. If the dust in the cabinet is large, please clear the external radiator of the inverter.

2. If the humidity is relatively large, there are condensation or water marks, please open the cabinet door first, ventilate and dehumidify, and use tools such as electric fans.

3. Start the electric fan of the electrical cabinet to exhaust. If the electrical cabinet is air-conditioned or heated, dehumidify it first.

4. Check the upstream and downstream equipment, including the incoming switch, contactor, outgoing cable, motor phase and phase to ground insulation, braking resistor and each DC terminal of the braking unit and the insulation between it and the ground. Ensure that the power terminal is free of looseness and corrosion.

5. Check the weak current lines, such as communication cables, I/O cables, etc., to ensure that they are firmly connected and free of looseness and rust.

More on that
Methods to reduce the maintenance cost of inverter - Senlan inverter Methods to reduce the maintenance cost of inverter - Senlan inverter

Frequency converter is a widely used equipment in modern factories. This is a very expensive new type of equipment, and the maintenance price of the inverter is also very expensive, so in the process of using the inverter, we should pay attention to the use of the inverter. Thing...

Motor inspection and maintenance, motor problems - Senlan Motor inspection and maintenance, motor problems - Senlan

1: In the operation of the motor, if dust, water stains and other debris enter its interior, it will constitute a short-circuit medium, which can damage the wire insulation layer, form an inter-turn short circuit, increase the current, increase the temperature and incinerate the motor. Therefore, dust, water stains and other debris should be prevented from entering the motor.

Sunland inverter does not show fault repair Sunland inverter does not show fault repair

After inspection, the circuit board of the machine is composed of a fan switching power supply board, a control board with a switching power supply and a driving board, etc., the fan power supply and the control board operation power supply are independent of each other, the fan power supply output is normal, and the control board operation power supply is not output due to the problem. ...

Analysis of soft start technology of asynchronous motor - Senland Analysis of soft start technology of asynchronous motor - Senland

The thyristor communicates the voltage regulation and soft starts The communication and voltage regulation soft engine of the thyristor is mainly to change the connection method of the thyristor, and the traditional connection method is changed to connect to the three windings, so that the power supply of the thyristor is completed by the method of parallel connection. Thyristor soft starters have a strong ...

The main circuit of the inverter application - Hope Sunland The main circuit of the inverter application - Hope Sunland

There is a circuit breaker QF and a communication contactor KM between the power supply and the inverter, when the inverter does not need to be used for a long time. or when the equipment is overhauled, the circuit breaker is used as an isolation switch, which can block the power supply and ensure the safety of maintenance. It has maintenance functions such as overcurrent and undervoltage. The main power of the inverter ...

What are the protection functions of the inverter - Sunland inverter What are the protection functions of the inverter - Sunland inverter

1. Incoming line maintenance Incoming maintenance is the maintenance of the user's inlet end and inverter, including lightning protection maintenance, grounding maintenance, phase loss maintenance, inverted phase maintenance, unbalance maintenance, overvoltage maintenance, transformer maintenance and so on. These maintenance devices are generally installed at the input of the inverter ...

PLC control belt conveyor soft start method PLC control belt conveyor soft start method

Belt conveyor is a kind of continuous conveyor, which is one of the main types of fixed or escorted cranes. Belt conveyor is the use of friction to convey the dynamic, with belts, steel belts, steel fiber belts and chemical fiber belts as a kind of compliance with the transmission of materials and traction operations.

Introduction to the classification method of inverter maintenance faults Introduction to the classification method of inverter maintenance faults

1. How to distinguish between heavy faults and light faults According to the occurrence time of inverter faults, we can divide the types of faults into two categories: sudden faults and intermittent faults: (1) The sudden fault of inverter repair refers to the failure of the equipment when it is running, without warning.

Effect of inrush current on inverter - Senlan Effect of inrush current on inverter - Senlan

In the process of repairing the inverter, we can find that because of the back electromotive force in the stator winding, the electromotive force in the synchronous generator state and the self-induced electromotive force in the self-loop rotor, the current impact will inevitably have a negative impact on the motor, the inverter (Variable-frequency ...

I/O (Input/Output) Selection – Senland I/O (Input/Output) Selection – Senland

In the 90s of the 20th century, PLC has formed a variety of PLCs: micro, small, medium, large and giant. According to the number of I/O points, it can be divided into five types: micro PLC (32 I/O), small PLC (256 I/O), medium PLC (1024 I/O), large PLC (4.69 I/O), and giant PLC (8195 I/O). ...

Inverter parameter setting - Sunland inverter Inverter parameter setting - Sunland inverter

There are many setting parameters of the inverter, each parameter has a certain selection scale, and the inverter can not work normally due to the improper setting of individual parameters in use, so it is necessary to set the relevant parameters correctly. ...

The basic requirements of VFD installation design - Sunland inverter The basic requirements of VFD installation design - Sunland inverter

(1) The VFD should be installed in the control cabinet. (2) The VFD is best installed in the center of the control cabinet; The VFD It should be vertically installed with the top and bottom protected from large parts that may obstruct the exhaust and intake. (3) VFD control cabinet or partition, or the upper and lower parts of the necessary device ...

The harm of low temperature to the inverter - Senlan The harm of low temperature to the inverter - Senlan

Most VFDs are suitable for -10°C-50°C, and if the temperature is too low, the VFD will be affected. Precautions for low-temperature operation of VFD: 1. VFD should be operated in an environment above minus 10°C as much as possible, preferably indoors.

Overload trip analysis of an inverter Overload trip analysis of an inverter

The motor is able to rotate, but the operating current exceeds the rated value, which is called an overload. The fundamental reflection of overload is that although the current exceeds the rated value, the fluctuation of the excess is not large, and it generally does not constitute a large inrush current. 1. The main reason for overload (1) Excessive mechanical load ...

Senlan wiring knowledge Senlan wiring knowledge

1. Wiring of fire emergency lighting Generally, the flame retardant wire is used to wear the metal pipe and the thickness of the protective layer is ≥ 30mm, in the decoration project, when the emergency lighting circuit can only be applied to the ceiling, the heat-resistant or fire-resistant wire should be selected and the fire-resistant and heat-resistant matching should be considered.

Sunland low-voltage inverter division series Sunland low-voltage inverter division series

1.HG1000 high-performance light-load intelligent inverter, the most cost-effective, the new series is widely used in medicine, food, packaging, cable, printing and dyeing, washing, centrifuge, dehydrator, sewage treatment, HVAC, constant pressure water supply, constant temperature control, flow control and other industries, such as fans and pumps, ...

Common problems in the use of inverter - Sunland inverter Common problems in the use of inverter - Sunland inverter

1. Please explain the maintenance function of the inverter? (1) After detecting the abnormal situation, the correction action will be carried out automatically, such as overcurrent loss rate prevention, regeneration overvoltage stall prevention. (2) After detecting the abnormality, the PWM control signal of the power semiconductor device is closed, so that the motor can park automatically. As...

Common problems in the use of inverters - Hope Sunland Common problems in the use of inverters - Hope Sunland

1. Please clarify the maintenance function of the inverter? (1) After detecting the abnormal situation, take the initiative to correct the action, such as overcurrent loss speed prevention, regeneration overvoltage stall prevention. (2) Block the power semiconductors after detecting the abnormality...

Hope Senlan inverter selection Hope Senlan inverter selection

Hope Sunland inverter is a high-performance inverter product, which has high operational reliability, high energy efficiency, strong control performance and long service life. Hope Sunland inverter has been widely used in industrial process production control, machinery control, water treatment, construction and transportation and other fields. This article will start with ...

Inverter super password summary Inverter super password summary

1. Delta's super password-B series: 57522; - H-series: 33582; S1 series inverter universal password: 575222. Second, Huifeng inverter (that is, now Ou Rui inverter), the general super password of its products is: 18881500-G 1500-P 1000- ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top