1. Problems of the inverter and the motor itself;
After the motor has been used for a long time, it cannot be ruled out that the insulation function is not good, or the bearing is stuck, and it may show a large current and heat. The coupling between the motor and the load may also be worn, or the three-phase imbalance of the motor, the fixture of the motor is loose, etc., which will cause abnormal movement and heating.
Some components of the inverter are aging, or there may be deviations between the vector parameters and the motor matching, or the parameters such as torque increase are set too large, or the acceleration and deceleration time is too short, or the carrier frequency of the inverter is too small, which may cause the motor and the inverter to heat up together.
The connection line between the motor and the inverter should not be too long, otherwise attenuation and waveform distortion will occur.
In some occasions where fast braking is required, it is necessary to purchase appropriate accessories such as braking resistors and braking units according to the braking power.
2. Long-term operation of low-frequency conditions;
Generally, it is not suitable to plan the motor operation below 8HZ, even if it is a vector control inverter, it is necessary to try to prevent this use, mainly in the case of low frequency, the waveform is severely distorted, and the distance between the sine wave is too far, the motor operation function is poor, and the torque is severe attenuation and heating. The target can be achieved by increasing the gear ratio and then increasing the output frequency of the inverter.
If you must work in a low-frequency condition for a long time, you can use a special inverter motor, or maybe the motor is forced to be air-cooled or even water-cooled to cool down.
Optimize the operating environment:
In the past, the economic conditions were not good, many small factories did not plan an independent control room, even if there was a control room, there was no air conditioning for the control room, now the conditions are good, it is completely possible to use the inverter and other equipment in the controller with air conditioning, so that the temperature of the inverter is in a better condition, not easy to heat, and also due to the reduction of dust and so on to extend the service life, in detail, it is actually a better investment.
3. Pay attention to the correctness of selection;
The motor is the heart of the equipment and the power source for almost all loads. When planning the selection of equipment, the demand takes into account the torque and power of the load demand, so as to select the appropriate motor power and torque, if the capacity of the motor is small, it is equivalent to a small horse-drawn heavy car, of course, the motor itself is in an overload operation situation, and it will be severely heated.
In the same way, if the specifications of the inverter are also small, the inverter has been higher than the rated current for a long time, the same will be severely heated, and it will soon present a problem to burn off, the selection is small, and it can only be replaced with a larger type to deal with, this is a rigid requirement of things, and there is no shortcut, it must be dealt with in time, even if you dismantle the existing one as a second-hand sale is better than continue to use, after all, the problem delays production, Maybe some explosions due to fever and other problems, or maybe fire accidents, that's a big deal.
Although some loads do not seem to be heavy, they involve frequent start-ups and aborts, which also require amplified power to be used, otherwise they will face the same problems mentioned above.
4. Problems with equipment and load;
Mechanical equipment may be loaded, if there is any abnormality, such as the gear of the transmission mechanism or the bearing is broken, then the resistance becomes larger, the output of the motor will also become larger, some conditions are severe, or the motor stall phenomenon may be presented, the current will be very large, although most of the inverter will cause overload and overcurrent to cause alarm shutdown, but there are also some in a critical situation, perhaps the protection parameters of the inverter are not set, and the same will form abnormal phenomena such as heating. In this situation, of course, it is necessary to start from the mechanical equipment and load to solve the problem.
For example, the inverter controls some liquid transfer pumps or air supply fans, etc., due to problems such as dirty pipelines and bending, the current of the motor and inverter is too large due to the formation of resistance, which should be cleaned in time.
|
More on that
|
Control method of Reynolds inverter
The fulfillment device commonly used in the industrial field of Reynolds inverter has good speed regulation performance and simple and convenient operation method. Therefore, it is widely used in the automation system.
Typical wiring method for the main circuit of a Reynolds frequency converter
...
|
|
The external configuration of the inverter is solved - Reynolds
With the improvement of the degree of automation of packaging machinery, packaging machine inverter (hereinafter referred to as VFD) plays an increasingly important role in packaging machinery. Capsule filling machine, high-speed tablet press, bottling production line, aluminum-plastic packaging machine, cartoning machine, each equipment will use VFD, mainly ...
|
|
Reynolds inverter FAQ - parameter class
1. What are the factory parameters of inverter rehabilitation?
N600 = 100 (often press the WR button for 3-5 seconds), it is necessary to be in the shutdown state to be effective.
2. In the parameters of the N308 motor of the inverter, [motor leakage inductance reactance] is the specified sub...
|
|
Features of the unit tandem inverter - Reynolds
(1) The multi-pronged PWM control method is selected, and the output voltage waveform is close to the sine wave.
(2) The rectifier circuit is multiplied, the number of pulses is as high as 36, the power factor is high, and the input harmonic is small.
(3) Modular design, compact structure ...
|
|
Motor overload fault solution - Reynolds
Causes of inverter failure:
1. The grid voltage is too low
2. The rated current of the motor is set incorrectly
3. The motor stall or load abrupt change is too large
4. Large horse-drawn trolley
Inverter solutions:
1 ...
|
|
Reynolds inverter power selection
The system power is equal to the product of the power of a general-purpose inverter and the power of the motor. As long as both work efficiently, the system power will be higher. From the perspective of power, when choosing VFD power, you should pay attention to the following points:
VFD ...
|
|
Centrifugal fan inverter selection method - Renol
1. See if it is energy-saving.
When selecting equipment products, many business managers will take into account the energy-saving embodiment, which is due to the excellent energy-saving embodiment of the product, which can save a lot of money and resources.
|
|
Reynolds soft starter troubleshooting methods
Common troubleshooting methods for Reynolds soft starters.
During the debugging process of the soft starter, the fault light is on, the motor is unresponsive, and the cause of the fault is analyzed:
When the starting mode adopts the live mode, the operation sequence is wrong (the correct operation sequence must first deliver the main power supply, and then the control ...
|
|
The breaking capacity of the industrial control appliance switch
Assuming Icu=60KA, then when a faulty current of 60KA is generated in the line, the circuit breaker can safely cut off the circuit without abnormal conditions such as contact welding and blasting. Pay attention to the extreme breaking ...
|
|
The relationship between Reynolds motion control and frequency converters
Motion control has obvious period characteristics, it is a variety of high-tech generalization, used to push industrial automation, office automation and home automation to a higher stage. Nowadays, motion control is mainly composed of variable frequency drive (VFD), electric motor, control ...
|
|
Precautions for the use of frequency converters - Reynolds
In order to ensure the safe, efficient and reliable operation of the inverter, the following keys should be grasped when using the inverter:
1) It is necessary for the grounding terminal of the inverter to be firmly grounded, so as to effectively press the radio frequency disturbance and enhance the reliability of the system: the frequency conversion speed regulation system is best to use independent grounding, grounding resistance...
|
|
Inverter frequency regulation fault solution - Reynolds
Most of the applications of frequency converters (hereinafter referred to as -VFDs) are primarily due to the fact that VFDs can change the output frequency and thus change the speed of the motor. If the frequency of the VFD cannot be adjusted and no damage is found on the hardware, it can be considered that the maximum output torque of the VFD is less than the load progress torque ...
|
|
The item that needs to be maintained after the inverter is shut down – Reynolds
1. Use a vacuum cleaner with a plastic nozzle to thoroughly clean the inside and outside of the inverter cabinet to ensure that there is no excessive dust around the equipment.
2. Check the ventilation and lighting of the frequency conversion room, and the ventilation equipment can operate normally.
3. Check the inverter ...
|
|
The difference between the voltage type and the current type of inverter - Reynolds
Energy storage elements are different, the voltage type energy storage element is a capacitor, and the current type is an inductor. In fact, the general inverter uses power electronic circuits, which is a process of communication to DC - DC energy storage - DC to communication. It is also often said that the rectifier link --〉 energy storage link --〉 inverter ring ...
|
|
Dust design considerations for frequency converters - Reynolds frequency converters
1) The air duct of the inverter cabinet should be planned reasonably, and the exhaust should be clear and smooth, so as to avoid the formation of vortex in the cabinet and the accumulation of dust in a fixed direction.
2) The top air outlet of the inverter cabinet should be equipped with a protective top cover to avoid debris from falling directly.
|
|
Introduction to soft starters and their relationship with frequency converters - Reynolds
When the high-power motor starts, the current is large, which will cause the grid voltage to be seriously shaken, in order to deal with this problem, the general requirements for speed regulation are not high, and the soft engine can be used to reduce the voltage and start. However, the drop in the starting current when the step-down is started will also make the starting torque drop significantly.
|
|
Elimination of inverter harmonics method – Reynolds
a. Add the internal impedance of the power supply of the inverterIn general, the internal impedance of the power supply equipment can play a role in buffering the reactive power of the DC filter capacitor of the inverter. This internal impedance is the short-circuit impedance of the transformer. When the power supply capacity is smaller than the inverter capacity, the internal impedance value is relatively large.
|
|
The inverter protects the motor - Reynolds inverter
1. The output of the inverter for overvoltage maintenance has the function of voltage detection, and the inverter can actively adjust the output voltage, so that the motor does not bear the overvoltage, and the motor runs within the set voltage range.
2. Undervoltage maintenanceWhen the voltage of the motor is lower than 90% of the normal voltage (some are set to 85% ...
|
|
Reynolds soft starter problem solving
1. The soft starter does not start and the fault-free code appears, perhaps because the control power supply is not connected, the solution is to check the power supply of the control power supply to see if the circuit connection is correct.
2. The motor starts when the motor announces a hum/no start signal, perhaps because of the thyristor/module ...
|
|
Inverter leakage solution - Reynolds
1. The cause of the leakage problem
Some sites use frequency converters to control the motor, which will present the problem of leakage, and the leakage voltage ranges from tens of volts to 200 volts. In view of this problem, the reasons for this shortcoming are theoretically expounded and stated as follows.
Depend on...
|
|