1) Ramp boost soft start. This starting method is simple, does not have current closed-loop control, and only adjusts the conduction angle of the thyristor to make it add a certain function with time. The disadvantage is that because the current is not limited, in the process of motor starting, sometimes a large impulse current is generated to damage the thyristor, which has a greater impact on the power grid, and is rarely used in practice.
(2) Slope constant current soft start. This starting method is to gradually increase the starting current during the initial phase of motor starting, and when the current reaches a pre-set value, it remains constant (T1 to T2 stages) until the end of starting. During starting, the rate at which the current rises can be adjusted according to the motor load. If the current rise rate is large, the starting torque is large and the starting time is short. This starting method uses the most advanced starting methods, especially suitable for the starting of fans and pumps.
(3) Step start. Boot up, that is, in a short time, so that the starting current quickly reaches the set value, that is, step start. After adjusting the starting current set value, it can achieve a fast starting effect.
(4) Pulse impact start. At the beginning of the start-up stage, the thyristor is allowed to conduct at a large current for a period of time in a short period of time, then fall back, and then rise linearly according to the original set value, and connect to the constant current to start. This starting method is rarely used in general loads, and is suitable for starting occasions with heavy loads and large static friction.
|
More on that
|
Reynolds JJR5000 Series Soft Starter Manual
Reynolds JJR5000 series all-digital intelligent communication motor soft engine adopts power electronics skills, microprocessor skills and modern control theory skills, and is a new type of engine equipment at the current level. The product can limit the starting current of the asynchronous motor when it starts, and is widely used in electric fans, ...
|
|
The soft starter output is out of phase fault
Soft Starter Repair Problem: F 04 (Input Phase Loss):
There are several factors that cause this problem, some of which are listed below:
(1) Check whether the wiring between the incoming power supply and the motor is loose;
(2) Whether the output is connected to the load, and whether the load is matched with the motor;
(3) ...
|
|
Frequency characteristics of Reynolds frequency converters
a. Output frequency scale. The output frequency scale that can be controlled by the general inverter, the lowest starting frequency is generally 0.1Hz, and the highest frequency is different according to the functional indicators of the inverter, generally 400Hz, and some models are 650Hz. No matter how high the output frequency is, it depends on the scale of the high-frequency inverter.
...
|
|
General Purpose Inverter Repair Inspection – Reynolds
The first step is to check whether the appearance of the inverter is defective, including whether the indicator light is in normal operation, whether the mission control function of the operation panel is complete, and carefully observe the appearance of the inverter under the operating condition, and do the corresponding recording operation; When repairing the inverter, check whether the voltage value and current value exceed the ...
|
|
Applicable mode of inverter maintenance - Reynolds inverter
CNC cutting machine
1. Gradual reduction method
The so-called gradual reduction method is to narrow the scope of shortcomings step by step by elaborating the shortcomings and judging the measurement parameters.
|
|
Parameter setting of acceleration and deceleration time of Reynolds universal inverter
The acceleration time of the Reynolds inverter is the time required for the output frequency to rise from 0 to the high frequency, and the deceleration time is the time required to drop from the high frequency to 0. Usually, the inverter uses the frequency setting signal to rise and fall to confirm the acceleration and deceleration time. When the motor accelerates, the rise of the frequency setting must be constrained ...
|
|
PLC and inverter communication mode
1. The switching signal of PLC controls the inverter
The PLC can control the start, stop and reset of the inverter through the program; It can also control different combinations of high-speed, medium-speed and low-speed terminals of the inverter to achieve multi-stage speed operation. However, because it is controlled by switching ...
|
|
The difference between frequency converter and power saver - Reynolds
Many people don't have a clear idea of the detailed differences and uses of AC converters and power savers. Power savers are generally divided into lighting appliances and power savers. Using high-voltage filtering and energy absorption skills, it automatically absorbs the energy of the reverse potential of high-voltage power equipment, and continuously feeds back ...
|
|
Introducing the Reynolds JJR8000 series of intelligent soft starters
JJR8000 series of intelligent motor soft starter is the use of power electronics skills, microprocessor skills and modern control theory skills to produce today's international first-class starting equipment, the product can constrain the starting voltage of the asynchronous motor when starting, can be used in fans, water...
|
|
Application misunderstandings and drawbacks of inverter and countermeasures - Reynolds
Misunderstanding: connect electromagnetic switches and electromagnetic contactors in the output circuit of the inverter
In actual use, some occasions require the use of contactors for frequency converter switching: such as when the frequency conversion is faulty, switch to the power frequency operation, or when the one-to-two method is adopted, a motor is faulty, and the variable frequency is used.
|
|
AC servo motor with inverter control method - Reynolds
Because the inverter and servo are different in performance and function, and the use is not very different, it is not possible:
1) In the case of speed control and torque control, the general frequency converter is not very high, and there are also frequency converters that are used to react signals in the upper position to form a closed loop.
|
|
Inverter maintenance and undervoltage fault handling - Reynolds
In the repair of the inverter, we often hear about overpressure problems, but underpressure problems are also common problems encountered in the use of inverters. The reason is that the main circuit voltage is lower than the lower limit caused by the maintenance action or the damage of a rectifier bridge or the instantaneous power failure of the power grid, and the input is flat. Inverter after-sales ...
|
|
Wiring of Reynolds frequency converters
1 Main circuit wiring
(1) Reynolds inverter three-phase AC input terminal (R, S, T)
The power input terminal is connected to the three-phase AC power supply through the circuit breaker of the circuit breaker for line protection, regardless of the connection phase sequence. It should be noted here that the three-phase AC power supply is not ...
|
|
Fault signal of the frequency converter - Reynolds frequency converter
There are three types of fault signals for the inverter:
(1) Excessive mechanical load: The primary feature of excessive load is that the motor heats up, and the operating current can be read from the display screen to find. The primary reason is that the load of the inverter is too large, and the acceleration and deceleration time and operation cycle time are too short; V/F ...
|
|
Reynolds JJR5000 introduction to soft starters
The cost performance of Reynolds JJR5000 soft starter is relatively high, which is mainly reflected in the following aspects:
1. The price is more reasonable: compared with other similar products, the price of Reynolds JJR5000 soft starter is more affordable, and the price is in a more advantageous position among the products of the same level.
|
|
Reynolds inverter power selection
The system power is equal to the product of the power of a general-purpose inverter and the power of the motor. As long as both work efficiently, the system power will be higher. From the perspective of power, when choosing VFD power, you should pay attention to the following points:
VFD ...
|
|
Parameter setting of acceleration and deceleration time of Reynolds universal inverter
The acceleration time of the Reynolds inverter is the time required for the output frequency to rise from 0 to the high frequency, and the deceleration time is the time required to decrease from the high frequency to 0. Generally, the frequency converter uses the frequency setting signal to rise and fall to confirm the acceleration and deceleration time. The rise of the frequency setting must be limited when the motor accelerates.
|
|
Inverter power modification method - Reynolds
1. Yaskawa inverter G5-G7 power correction: enter the menu and then return to 02-04 after A01=4 is the power data, and the factory voltage of rehabilitation has also changed after the change.
2. Sanken inverter IHF-IPF-SHF series: enter the CD900 parameter and enter 365 to confirm (change 2 times...
|
|
Reynolds assisted Sinopec Weirong shale gas project
With the rapid development of China's national economy, the supply and demand situation of oil and gas resources is becoming increasingly severe, and the import of oil and gas is increasing year by year, so it is urgent to expand the field of domestic oil and gas exploration and development. Strengthening the exploration and development of shale gas resources can make up for the lack of conventional oil and gas resources and promote the sustainability of the oil and gas industry.
|
|
The structure of the low-voltage circuit breaker - Reynolds
Low-voltage air circuit breaker, also known as active air switch or air switch, belongs to the switch electrical appliance, is used when the circuit is overloaded, short circuit and undervoltage can actively break the circuit of the electrical appliances, can also be used as infrequent start of the motor or opening and closing circuit, low-voltage air circuit breaker has an all-round circuit breaker ...
|
|