Delta MS300 Inverter Series: Delta's compact standard vector-operated inverter MS300 combines the advantages of miniaturization, high functionality, high trust, and simple installation, transforming every investment in industrial resources into abundant results. Optimized structure and lock-free screw terminals plan the maintenance process for the supply of convenient goods.
Delta inverter VFD-L series: Specially designed for small horsepower motors, it has a built-in EMI filter to effectively suppress electromagnetic interference.
Delta Inverter VFD-C2000 Series: High-end magnetic beam vector control inverter, this series has high-efficiency inverter drive skills with FOC control as the core, and its diversified drive control, modular planning, rich industrial use functions, and market price competition.
Delta inverter VFD-M series: a high-functional, low-noise miniature inverter, this series provides medium and high horsepower power, with the characteristics of light size and quiet operation; In addition, the product selects a variety of protection skills, which significantly improves the anti-interference ability of the whole machine.
Delta Inverter VFD-B Series: Delta's inverter VFD-B is a new generation of high-functional, non-inductive vector-controlled inverter, which not only provides diversified I/O functions, but also can supply appropriate current and voltage vector values according to the external load torque, satisfying the most practical needs of the industry.
Delta Inverter VFD-CH2000 Series: Delta's CH2000 series high-performance vector inverter integrates IM/PM motor control to meet the special needs of impactful instantaneous loads, high overloads, and heavy loads in the fields of lifting, transportation, and CNC machine tools.
|
More on that
|
Misunderstandings in the application of Delta inverters
The capacity selection of the inverter is based on the rated power of the motor
Myth: The capacity selection of the inverter is based on the rated power of the motor
Compared with the electric motor, the price of the inverter governor is more expensive, so it is important to ensure that the ...
|
|
Introduction to Constant Power and Constant Torque in Frequency Conversion Speed Regulation - Delta
In general, factory motors are based on the additional speed values obtained at a given power frequency voltage (380 V, 50 Hz). If 380V is not reached under actual operating conditions, e.g. as long as 300V, 50 Hz, the voltage is significantly undervoltaged. Fundamentally, it cannot reach the extra rev value, due to the ...
|
|
The frequency of the inverter is given in a given way - Delta
The main way to use the inverter is to change the output frequency to achieve the controllability of the motor speed, so do you know what steps are required to complete the output frequency controllability? One of the main points is how to complete the change of the frequency signal supplied by the inverter equipment.
|
|
Precautions for inverter selection - Delta
The selection of the inverter is mainly determined by the load characteristics of the drive and the actual working current of the motor, in addition to the following precautions:
1. The environment is suitable for some high temperature (higher than 50 degrees) and high altitude (higher than 1000 meters).
|
|
Delta's servo protection parameters are written
A3, B3 servo
P5-97 Motion Control Mobilization Commands
0x0003 Maintenance Activation (Successful Return 0x1003)
0x0004 Maintenance Waiver (Successful Return 0x1004)
If the wrong cipher code is entered, the error code Ennn will be sent back to exempt the loss, during which nnn indicates that there is a ...
|
|
Delta's inverter process setting
1. Restore the inverter to factory settings, press the "ENTER" button to enter the parameter setting interface, and press it continuously until it is 00-00 and then stop. Press the number up button to change to 00-02. Press the "ENTER" key again, the panel value will show 0, press the number up key to change it to 9. Press the "ENTER" key, break ...
|
|
Delta's PLC-Based motion controller AX3 series
With the development of electronic semiconductor information technology, technologies such as the Internet of Things, big data, and cloud channels are showing a trend of hundreds of schools of thought, which also drives the rapid development of intelligent production. Intelligent production also puts forward new requirements for controllers: high speed, large capacity, miniaturization, networking...... In order to ...
|
|
Delta's A2 server maintenance location controller is faulty
Delta's A2 series servo system is one of the more common and used servers on the market today, and the following describes the fault details of the azimuth controller in the repair of Delta's A2 servo drive and the corresponding repair methods
Delta ...
|
|
Voltage regulator selection method - Delta inverter
1. Capacity safety factor
The AC regulated power supply is based on the output apparent power (kVA) as the nominal rated capacity, and the load is not purely resistive under normal circumstances, that is, the power factor COS¢≠1, and the active power that the regulator can output in practice kW = capacity (kVA) × COS¢. So in the real ...
|
|
Delta's servo motor maintenance and safety measures
Delta's servo motor system is planned for industrial use, and it is necessary to have a sufficient understanding of the motor standards and operation manuals before operating the motor. For the safety of the operator and equipment, and to ensure that the motor can be used correctly, please read this safety precaution carefully before installing the machine.
...
|
|
Delta servo system composition
The servo system is mainly composed of a servo controller, a drive circuit, a servo motor and the corresponding reaction testing equipment.
(1) Servo motor
Servo motor refers to the motor that controls the mechanical components in the servo system, and the servo motor has an encoder inside, which can respond to the movement in real time.
|
|
Tips and methods for using PLC - Delta PLC
First, the selection of output module
The output modules are divided into transistors, triacs, and contact types:
(1) The switching speed of the transistor type is fast (generally 0.2ms), but the load can be small, about 0.2-0.3A, 24VDC, suitable for fast switching, signal contact...
|
|
Problems with Delta's compact pressure transmitters
1. The transmitter does not return to zero under no pressure?
Answer: The cleaning method is to remove the transmitter from the device position, investigate whether the zero position is normal, and replace the pipeline sealing ring if it is normal. Check together whether the transmitter is perpendicular to the piping assembly, and if not, adjust the transmitter zero.
...
|
|
EMC Filter Installation Considerations – Delta
All electronic equipment (including frequency converters) will generate some high-frequency or low-frequency noise during normal operation, and disturb the peripheral equipment through conduction or radiation. If the right EMC filter can be configured and the correct device method can be used, the disturbance can be reduced to a minimum. ...
|
|
Delta's inverter is powered on and commissioned
After the installation of the Delta inverter is completed, disconnect the output of the inverter, use the diode file of the digital meter to measure the input and output of the inverter before the power is not turned on to ensure that there is no short circuit, and then turn on the operating power supply of the inverter.
|
|
Principles of daily protection and maintenance of Delta inverters
1. Record the operation data and shortcomings of the Delta: The operation data of the Delta inverter and the motor should be recorded every day, including the output frequency, output current, output voltage, DC voltage inside the inverter, radiator temperature and other parameters, and compare them with reasonable data, so as to facilitate early detection of defects.
|
|
Delta's inverter power-on debugging method
After the inverter is installed, disconnect the output of the inverter, use the diode file of the digital meter to measure the input and output of the inverter before the power is not turned on, ensure that there is no short circuit, and then turn on the working power supply of the inverter.
|
|
Productivity maintenance tips for Delta drives
1. When the Delta inverter breaks down in the future, it is best not to hand it over to someone who has no experience in repairing the inverter to repair the inverter, otherwise it may get worse and worse. Sometimes it's about to fuse, be sure to check whether there is a problem with the module, some electricians have not experienced it, and immediately install a good fast melt (definitely not ...
|
|
Delta's inverter power-on debugging method
After the inverter is installed, disconnect the output of the inverter, use the diode file of the digital meter to measure the input and output of the inverter before the power is not turned on, ensure that there is no short circuit, and then turn on the working power supply of the inverter.
|
|
Excessive inverter capacity poses a hazard to electrical equipment – Delta
(1) The harmonic current will directly cause the additional heating of the motor, so that the stator of the motor will exceed the rated temperature rise of the motor itself, so that the rated output capacity of the motor will be greatly reduced.
(2) The current wave output of the inverter ...
|
|