The selection of the inverter is mainly determined by the load characteristics of the drive and the actual working current of the motor, in addition to the following precautions:

                                  Precautions for inverter selection - Delta

1. EnvironmentFor some high temperature (higher than 50 degrees) and high altitude (higher than 1000 meters) application occasions, the inverter selection should appropriately leave a certain margin to ensure the service life of the inverter and motor.

2. Distance

The distance between the inverter installation address and the drive motor is more than 50 meters, and the inverter should be selected with a reactor to reduce the carrier frequency.

3. One tow more

When a frequency converter drags multiple motors, if the cable connected in the middle is too long, the general frequency converter should be enlarged by one gear when selecting the model, and a fuse should be installed behind each motor.

4. High-speed motor

During the operation of the high-speed motor, a large number of harmonics will occur, which will enhance the output current of the inverter and generate a large amount of heat. Therefore, the inverter should also be one gear larger than the ordinary motor when selecting the model.

5. Explosion-proof motor

In some mines and oil exploitation environments, when the frequency conversion system is an explosion-proof motor, the frequency converter should be selected with explosion-proof function, and the frequency converter should be placed in a safer place.

6. Protection level

For dusty and wet applications, pay attention to the protection level of the inverter when selecting it. Maybe choose the AMB inverter, the fan can run even in water.

7. Single-phase motor

When a single-phase motor is used in the field, the inverter is useless.

8. Pole-changing motor

When the pole changing motor is used in the field, the inverter should be selected to ensure that the large working current does not exceed the rated current of the inverter, and the number of poles of the motor should be converted to avoid idling and damaging the inverter.

More on that
How Delta's touch screen works How Delta's touch screen works

Delta's touch screen consists of a contact detection component and a touch screen controller. The contact detection component is installed in front of the display screen to detect the user's contact orientation and is sent back to the touch screen controller; And Delta's touch screen controller's ...

Principles of daily protection and maintenance of Delta inverters Principles of daily protection and maintenance of Delta inverters

1. Record the operation data and shortcomings of the Delta: The operation data of the Delta inverter and the motor should be recorded every day, including the output frequency, output current, output voltage, DC voltage inside the inverter, radiator temperature and other parameters, and compare them with reasonable data, so as to facilitate early detection of defects.

Delta servo system composition Delta servo system composition

The servo system is mainly composed of a servo controller, a drive circuit, a servo motor and the corresponding reaction testing equipment. (1) Servo motor Servo motor refers to the motor that controls the mechanical components in the servo system, and the servo motor has an encoder inside, which can respond to the movement in real time.

Delta UPS uninterruptible power supply R-2K series Delta UPS uninterruptible power supply R-2K series

With the increasing demand for system switching power supply by computer technology, Delta UPS uninterruptible power supply R-2K series products have been paid more and more attention, and gradually developed into a kind of electrical engineering with the effects of voltage stabilizer tube, frequency stabilization, filtration, anti-electromagnetic and frequency emission influence, anti-operation voltage swimming, etc.

Inverter environmental installation requirements and methods - Delta inverter Inverter environmental installation requirements and methods - Delta inverter

1. The environmental requirements of the inverter Ambient temperature - 10 °C - 40 °C; Ambient humidity: The relative humidity does not exceed 90% (no condensation); Other occasions that require no direct sunlight, no corrosive gas and flammable gas, and less dust, with an altitude of less than 1000m. ...

Analysis of common faults of Delta servo motors Analysis of common faults of Delta servo motors

1. The shaft current of the motor is generated The current in the shaft-housing-base circuit of the motor is called the shaft current. Causes of shaft current: 1) Magnetic field asymmetry; 2) There is a wave in the supply current; 3 ...

Problems in the inverter application – Delta inverters Problems in the inverter application – Delta inverters

1. Harmonic problems The equipment that plays the role of switching in the main circuit of the inverter must generate harmonics in the process of turning on and off the circuit. The lower harmonics generally have a greater impact on the motor load and cause torque ripple; The higher harmonics increase the leakage current of the inverter's output cable, making ...

Delta's M300 series inverters are used in primary and auxiliary frequency applications Delta's M300 series inverters are used in primary and auxiliary frequency applications

I. Introduction Some devices will have many transmission organizations, and it is impossible for the transmission organization to achieve 100% speed synchronization, so it is necessary to introduce ------ The final motor speed of the pendulum roller is *** := main speed + (+-auxiliary correction change) Use the site ...

Introduction to Delta's PLC maintenance knowledge Introduction to Delta's PLC maintenance knowledge

1. Delta's PLC power on running light does not light up, and the ERROR flashes, the reason may be: no program 2. Delta's PLC cannot communicate with the computer, which may be: RS23 port is broken 3. Delta's PLC power light does not light up: The power supply is bad ...

Precautions for cleaning dust in the inverter - Delta Precautions for cleaning dust in the inverter - Delta

1. Each VFD should be cleaned and protected once a quarter. Protecting and cleaning equipment must have specific records and the signature of the person in charge. As long as the management is in place, the task can be completed with quality and quantity; 2. Before cleaning, the power supply must be blocked, and the voltage must be reduced to a safe voltage before starting to work. ...

Inverter maintenance is easy to ignore the problem - Delta Inverter maintenance is easy to ignore the problem - Delta

1. After the inverter is repaired, the power number needs to be corrected, don't forget it Generally, an inverter corresponds to a power number (also known as the number of horsepower), for example, a 75 kilowatt inverter is set under heavy load, and 100 kilowatts is set under light load. In this way, the customer will not use it to present ...

Delta's high-performance servo ASDA-A3 series is a new product Delta's high-performance servo ASDA-A3 series is a new product

With the rapid development of automation technology and shopping malls, customers have higher and higher requirements for the speed, accuracy and function diversification of servo products. In order to get used to the needs of shopping malls, recently, Delta launched the high-performance motion control high-end AC servo system ASDA-A3 series ...

Intelligent thermostat adjustment method - Delta Intelligent thermostat adjustment method - Delta

1. Set temperature: Press the SET button to set or view the temperature set point. Press the SET key digital tube character beginning flash, indicating that the appearance has entered the setting state, press the △ key to increase the set value, press the ▽ key to decrease the set value, press and hold the △ key or ▽ key The data will change rapidly, press the SET key again The appearance back ...

The reason why the circuit breakers of multiple stages trip together is Delta The reason why the circuit breakers of multiple stages trip together is Delta

Short-circuit maintenance (overload maintenance) is an important function of circuit breakers, and the reason why this function is achieved is that the circuit breaker senses the temperature in the circuit through a thermal iron plate. Once the temperature in the circuit is too high, it is transmitted to the mechanical mechanism in the circuit breaker for trip maintenance. ...

Delta's MH300 series technical specifications Delta's MH300 series technical specifications

Outstanding drive characteristics The overload capacity is up to 150% / 60 seconds, 200% / 3 seconds, suitable for constant torque, variable torque, constant power and other loads Support induction motor, permanent magnet synchronous motor, optional PG card for high ...

Common problems with compact pressure transmitters – Delta Common problems with compact pressure transmitters – Delta

1. The transmitter does not return to zero under no pressure? Answer: The cleaning method is to remove the transmitter from the device position, investigate whether the zero position is normal, and replace the pipeline sealing ring if it is normal. Check together whether the transmitter is perpendicular to the piping assembly, and if not, adjust the transmitter zero. ...

Precautions for the use of Delta inverter MS300 series Precautions for the use of Delta inverter MS300 series

Before operating the MS300 series products, please read and pay attention to the relevant safety information to ensure your own safety and product safety. When operating the wiring and installing the inverter, it is necessary to confirm that the power supply is closed. After blocking the communication power supply, the inverter POWER indicator (located in ...

Replaced by discontinued models of Delta inverters Replaced by discontinued models of Delta inverters

Delta's new generation of compact and efficient vector-controlled inverter MH300, adhering to the good driving function of Delta's inverter, has six advantages: compact size, flexible application, stable system, reliable quality, and easy installation.

What are the series of Delta inverters? What are the series of Delta inverters?

1:VFD-EL,VFD-S,VFD-L,VFD-C200 Voltage 220V, 380V, power scale 100W-7.5kw The above series are Delta's simple inverters, commonly known as economical inverters, which are used for small fans and pumps, conveyor belts on food and pharmaceutical machinery, etc., and are used for abbreviated ...

Delta's MZM position drive system is used for precise application of large inertia Delta's MZM position drive system is used for precise application of large inertia

Driven by consumption promotion and product diversification, the manufacturing industry's demand for automation and intelligent promotion in production and processing is also increasing. In the production process, the processing of "large and heavy" items is often difficult to control accurately, and the error of orientation is not as easy as that of "small" items. To this end ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top