Soft starters and frequency converters are two completely different products. The inverter is used in the local area where speed regulation is required, and its output not only changes the voltage but also changes the frequency at the same time; A soft starter is actually a voltage regulator, which is used when starting a motor, and the output only changes the voltage and does not change the frequency. Change...
|
|
How long is the cable between the inverter and the motor allowed - Reynolds
The voltage waveform output by the inverter is only similar to a sine wave, but not a real sine wave, and its waveform contains a large number of harmonic components.
As we all know, the higher harmonics will increase the output current of the inverter, causing the motor winding to heat up.
|
|
"RNB6000 frequency conversion governor" was included in the National Torch Program
Recently, in the "2012 National Torch Program Project" issued by the Ministry of Science and Technology of the People's Republic of China, the "RNB6000 Frequency Conversion Governor" independently developed by Reynolds was included in the "2012 National Torch Program Project" with its domestic leading skills and efficient energy-saving conversion power.
|
|
Inverter maintenance power-on test instructions - Reynolds
First, the inverter is not repaired and the power test is tested
(1) Inverter repair test rectifier circuit
At the two ends of the inverter to detect the internal DC power supply, P and N ends, adjust the multimeter to the resistance RX10 gear, the red watch pen is connected to the P end, and the black watch pen is connected to R, S, T, and there are tens of ohms under normal conditions.
|
|
The item that needs to be maintained after the inverter is shut down – Reynolds
1. Use a vacuum cleaner with a plastic nozzle to thoroughly clean the inside and outside of the inverter cabinet to ensure that there is no excessive dust around the equipment.
2. Check the ventilation and lighting of the frequency conversion room, and the ventilation equipment can operate normally.
3. Check the inverter ...
|
|
Overheating failure light on start-up analysis - Reynolds
(1) Frequent starting, resulting in excessive temperature, causing overheating maintenance of soft starter. (The number of starts of the soft starter should be controlled to no more than 6 times per hour, especially for heavy loads)
(2) During starting, ...
|
|
Common faults and solutions of vector inverter - Reynolds
The following faults may be encountered during the use of the inverter, please refer to the following methods for simple fault analysis:
1. No manifestation at power-on:
1) Use a multimeter to check whether the input power supply of the inverter is consistent with the rated voltage of the inverter, and check the cleaning problem.
2) ...
|
|
Inverter acceleration and deceleration mode selection
The selection of the acceleration form and deceleration form of the inverter is also called the selection of acceleration and deceleration curves. Generally, there are several forms of inverter, such as linear, S-shaped, semi-S-shaped, etc., and the characteristics and uses of each form are as follows.
1. Linear form
The form makes the inverter ...
|
|
Reynolds inverter E.oC3 constant speed operation overcurrent fault solution
Reynolds inverter RNB1000 series E.oC3 constant speed operation overcurrent fault solution
Reynolds inverter fault codes:
E.oC3
Reynolds inverter fault phenomenon/type:
Constant speed operation overcurrent
Possible causes of Reynolds inverter failure:
...
|
|
Inverter power modification method - Reynolds
1. Yaskawa inverter G5-G7 power correction: enter the menu and then return to 02-04 after A01=4 is the power data, and the factory voltage of rehabilitation has also changed after the change.
2. Sanken inverter IHF-IPF-SHF series: enter the CD900 parameter and enter 365 to confirm (change 2 times...
|
|
Inverter installation and heat dissipation treatment - Reynolds
The inverter has power loss during operation and converts it into heat energy, which increases its own temperature. Roughly speaking, the power loss of every 1kVA inverter capacity is about 40W-50W. Therefore, when installing the inverter, it is necessary to consider the heat dissipation of the inverter, and how to run the inverter.
|
|
Frequency converter overcurrent problem treatment - Reynolds
General treatment methods for inverter overcurrent problems:
The output side of the inverter is a PWM voltage waveform, and after passing through the motor winding, the output current is approximately a sine wave, and lags behind the voltage by a phase viewpoint, which is determined by the power factor of the motor. The output current of the inverter passes through ...
|
|
Soft-start starting method – Reynolds
1) Ramp boost soft start. This starting method is simple, does not have current closed-loop control, and only adjusts the conduction angle of the thyristor to make it add a certain function with time. The disadvantage is that because there is no current limit, in the process of motor starting, sometimes a large impulse current is generated.
|
|
Frequency converters need to be replaced regularly – Reynolds
The inverter is composed of many electronic parts, such as semiconductor components, etc., in the application and protection involves the replacement of a related component, because of the composition or physical characteristics of the inverter, it will deteriorate in a certain period of time, which will reduce the characteristics of the inverter, and even ...
|
|
Reynolds frequency converters are remotely controlled for wiring
1. Connect X (switching input) drive terminal to control the inverter start-stop/positive rotation;
2. Connect to the AI (analog input) terminal to control the frequency of the inverter (perhaps made into PID closed-loop control automatic adjustment frequency)
3. ...
|
|
Reynolds soft starter fault code and fault handling
Reynolds soft starter fault code
Instantaneous stop -F 01 Instantaneous stop terminal 7 to terminal 10 open
TOO LONG STARTING TIME -F 02 STARTING TIME IS TOO LOW AND THE STARTING TIME IS TOO LONG (GREATER THAN 60S)
Overheating -F 03 Start too often, reduce the number of starts
Input out of phase -F 04 ...
|
|
What inverter to choose what occasion - Reynolds
We need to ensure that the capacity of the inverter is matched. First of all, according to the nature of the load, the correct selection of the type of inverter.
When selecting the inverter, the current value of the actual motor should be used as the basis for the selection of the inverter, and the rated power of the motor can only be used as a ...
|
|
Classification and working principle of Reynolds inverter
Classification of Reynolds frequency converters:
There are many classification methods for Reynolds inverters, which can be divided into voltage-type inverters and current-type inverters according to the classification of the main circuit operation method; According to the classification of switching methods, it can be divided into PAM operation.
|
|
Operating procedures for Reynolds frequency converters
Bypass cabinet: The cabinet is equipped with high-voltage inlet and outlet isolation switches QS1 and QS2. Among them, QS1 is a single-pole single-throw variable frequency incoming knife switch, and QS2 is a single-pole double-throw power frequency and variable frequency outgoing knife switch. The bypass cabinet is a high-voltage environment, please investigate the status of the live display and electromagnetic lock to ensure safety before ...
|
|
Use the right power for the inverter – Reynolds
Low pressure issues
The VFD reports a low voltage glitch when the drive's DC link voltage drops below 62% of the nominal level at the high setting (480 Vac) and 50% of the nominal value at the low setting (400 Vac).
The +10% and -15% voltage tolerances in most manuals are the ones that claim to be ...
|