Introduction to Xinjie touch screen TP

Create Date: 2024-8-30 12:03:23|Source: XINJE

1. Introduction

                               Introduction to Xinjie touch screen TP

TP Contact Industrial Graphic Displayer (referred to as contact screen) is a human-machine interface (known as HMI or MMI in foreign countries) that connects humans and machines (mainly PLC), which is known as the face of PLC. It is an intelligent operation display that replaces the traditional control panel and keyboard. It can be used for parameter setting, data display, depicting the automatic control process in the form of curves, animations, etc., and can simplify the control program of the PLC. Compared with the advantages of imitating instruments and console control:

1) The volume becomes smaller, and it does not take up space;

2) Simplified connection.
  ​
2. The main role of TP contact screen

Supervision: Reflect the internal status of the PLC in various forms such as data, curves, graphics, animations, etc., store the values, and then intuitively reflect the process and direction of the industrial control system.

Operation: The internal bit status of the PLC can be changed through contact operation, the memory value, and then participate in the process control.

3. The main functions of TP contact screen

1) Perform the control process in the form of animation, complete the working condition diagram and flow chart, and the equipment will be displayed from static to operational, and the picture will imitate the animation;

2) ON/OFF indication of discrete points; It can complete the color change of pipes, valves, and indicator lights, the opening and closing of electrical switch switches, the opening and closing of baffle switches, and the completion of multiple switches.

3) Parameter setting, data display; Data tables can be designed, and simulation images of manufacturing operation panels can be manufactured;

4) bar chart, (semi) pie chart, container chart, trend chart and various instrument displays; It can manufacture the simulation image of the operation panel, and complete the change of signal value and liquid depth; mimic the movement of the header pointer or cursor, etc.;

5) Various alarm actions: if there is an abnormal situation in the production process, take the initiative to alarm and display the type of fault with text, and the screen will actively switch to the process screen of the fault location at the same time;

6) can be used for report printing (non-screen hard copy), alarm information printing, printing timing can be confirmed by the user; It can be connected to CCTV supervision head (NTSC standard) to display real-time information on site.

7) Move the original switch and indicator light to the contact screen, which can save the input and output points corresponding to the switch and indicator light on the PLC, and then reduce the planning of the PLC system.

8) Authority: The operator can only enter the operation status after entering the correct login password when turning on the machine

4. Characteristics of TP contact screen under harsh conditions:

1) Dustproof and earthquake-resistant

2) Waterproof and anti-electromagnetic
More on that
XLH Series 32-Axis EtherCAT Bus Controller - Xinjie XLH Series 32-Axis EtherCAT Bus Controller - Xinjie

Following the launch of XDH, XLH series 16-axis and other models, Xinjie has achieved good market feedback, and the XLH-30A32 low-profile controller to be launched today can be expanded by 32 bus nodes, and has better performance in basic performance and bus control ability. ...

How to choose an industrial display touch screen - Xinjie How to choose an industrial display touch screen - Xinjie

  1. Four-wire resistive touch screen: It is not afraid of dust, oil and photoelectric disturbance, and is afraid of scratches is its main defect. It is suitable for public places with fixed users, such as industrial control sites, offices, homes, etc.; 2. Five-wire resistor ...

How to properly ground the PLC - Xinjie PLC How to properly ground the PLC - Xinjie PLC

The grounding policy is nothing more than to avoid disturbance for safety, and the policy of grounding to PLC must not be attached to the disturbance at the power supply and input and output terminals, so the accurate grounding system is one of the primary methods for the PLC control system to resist electromagnetic disturbance. There are floating and direct grounding formations.

The solution to the overcurrent of the inverter - Xinjie The solution to the overcurrent of the inverter - Xinjie

1. On the premise of satisfying the production equipment and process requirements, the acceleration or deceleration time should be increased as much as possible, and then the overcurrent generation in the process of acceleration or deceleration can be avoided. 2. Check whether the inverter, motor, and production equipment are well matched, whether the transmission part is sensitive, and whether the material is ...

Xinjie fast positioning switching power supply method Xinjie fast positioning switching power supply method

Switch Mode Power Supply (SMPS) will cause the base of the switch tube to fail to get the switching pulse and intermittent operation due to the short circuit of the load, the failure of the vibration circuit itself and the loss of control of the protection circuit, which makes it difficult to locate the shortcomings of SMPS. Difficult to repair ...

Xinjie touch screen features and advantages Xinjie touch screen features and advantages

Xinjie touch screen is an extraordinary technology product developed by Xinjie Technology Company. It not only uses touchscreen skills, but also integrates cutting-edge skills in many fields such as human-computer interaction, visual arts, and information processing, bringing skills to users. ...

Application characteristics of PLC in the control of mixing plant Application characteristics of PLC in the control of mixing plant

1. High reliability The PLC adopts a series of anti-interference methods in hardware and software, so that it can be directly installed in the industrial site and operate safely and reliably, anti-magnetic, anti-seismic and dust-proof. 2. Programming is simple and easy to grasp ...

Can the Xinjie touch screen software be installed or used normally? Can the Xinjie touch screen software be installed or used normally?

Why can't the touch screen software be installed or used properly? 1. Before the device, please close the antivirus software and system optimization things; 2. After the device is successful, double-click the software convenience icon on the desktop, "Please set the display to be true color" prompt ...

Fault distribution of PLC control system - Xinjie Fault distribution of PLC control system - Xinjie

In order to shorten the early problem period, further extend the random problem period, and postpone the arrival of the wear and tear problem period, we will generally choose the method to take a certain approach at the beginning of the system planning.

The allowable length of the cable between the inverter and the motor - Xinjie The allowable length of the cable between the inverter and the motor - Xinjie

The voltage waveform output by the inverter is similar to a sine wave, but not a real sine wave. Its waveform contains a large number of harmonic components, especially the higher harmonics will increase the output current of the inverter, form the motor winding heating, produce vibration and noise, accelerate the aging of insulation, and even ...

The cause of the overcurrent of the Xinjie inverter The cause of the overcurrent of the Xinjie inverter

1. Non-short-circuit overcurrent, which is mainly due to: (1) The motor is severely overloaded. (2) The motor accelerates too fast. (3) Due to the U/f ratio (torque compensation) setting is too high, the motor is in a light load condition. 2. Short circuit ...

Xinjie launched the wireless transparent transmission module S-BOX-T Xinjie launched the wireless transparent transmission module S-BOX-T

   Wireless module introduction: W-BOX-T: Wireless WIFI module, XC, XD series can be used, occupying RS232 port; S-BOX-T S-BOX: 433MHZ MODULE, XC AND XD SERIES CAN BE USED, OCCUPYING RS232 PORT; XD-E1WT-A ...

The inverter controls the leakage of the motor The inverter controls the leakage of the motor

Because the current at the input and output ends of the inverter contains high-frequency components, the leakage current formed by the high-frequency components when the inverter is driven is greater than that when the grid power supply is supplied. Because there are many varieties of circuit breakers, in some cases, even the inverter wires and motors ...

Xinjie launched a professional solution for tapping machines Xinjie launched a professional solution for tapping machines

Tapping machine is a kind of machine tool that uses taps to process internal threads, and it is the most widely used internal thread processing machine tool. The tapping machine avoids the limitations of lathes, drilling machines or manual tapping, and saves time, labor, is not easy to rot teeth, and taps are not easy to break.

PLC input and output circuit debugging - Xinjie PLC input and output circuit debugging - Xinjie

1. Analog input (AI) loop debugging. Carefully check the address assignment of the I0 module; Check whether the loop power supply method (internal or external) is consistent with the field instrument; Use a signal generator to check the participating signals of each channel at the field end, generally taking three points of 0, 50% or 100%. ...

The main role and function of TP touch screen The main role and function of TP touch screen

The primary role of the TP contact screen Supervision: Reflect the internal bit status of the PLC in various ways such as data, curves, graphics, animations, etc., store the numerical value, and then intuitively reflect the process and direction of the industrial control system. Exercise...

Small PLC manufacturers introduce the classification of PLC - Xinjie Small PLC manufacturers introduce the classification of PLC - Xinjie

Small PLC manufacturers introduce that PLC products have a wide variety of products, and the specifications and performance are also different. The classification of PLCs is usually based on their structure, function and number of I/O points. 1. Classified by input/output points (1) ...

New models such as IoT industrial controllers and smart cameras have been launched New models such as IoT industrial controllers and smart cameras have been launched

From 14:00 to 15:20 on May 14 last year, the X-SIGHT visual brand conference with the theme of "Vision, Light Up Intelligent Manufacturing" was held online, officially announcing that Wuxi Xinjie and Intel will join hands to create a new era of intelligent manufacturing. X-SIGHT unveiled a new Intel chip-based ...

The difference between PLC and PAC - Xinjie The difference between PLC and PAC - Xinjie

PLC is the abbreviation of programmable logic manipulator, which is a digital operation manipulator with a microprocessor for automatic control, which can load control instructions into memory at any time for storage and fulfillment. PAC is an abbreviation for Programmable Automation Manipulator. PAC in industrial control ...

A brief description of the new model of Xinjie PLC A brief description of the new model of Xinjie PLC

1.XG1 series is the latest modular medium-sized PLC of Xinjie, aiming at the domestic high-end market. peculiarity Medium-sized series PLCs with powerful functions and larger storage capacity Support 4 channels of 200K high-speed pulse transmission ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top