How to choose an industrial display touch screen - Xinjie

Create Date: 2024-8-30 12:03:23|Source: XINJE

1. Four-wire resistive touch screen:

                            How to choose an industrial display touch screen - Xinjie

It is not afraid of dust, oil and photoelectric disturbance, and is afraid of scratches is its main defect. It is suitable for public places with fixed users, such as industrial control sites, offices, homes, etc.;

2. Five-wire resistive touch screen:

Excellent sensitivity and light transmittance, long service life, not afraid of dust, oil pollution and photoelectric disturbance, suitable for all kinds of public places, especially suitable for industrial control sites that require fine precision;

3. Infrared-sensing touch screen:

Low resolution, but not disturbed by current, voltage and static electricity, suitable for some harsh environmental conditions; It is suitable for all kinds of public places, offices and industrial control sites where the requirements are not very delicate without infrared rays and strong light disturbance;

4. Surface acoustic touch screen:

Pure glass material, the best light transmittance, long service life, good scratch resistance, suitable for all kinds of public places. However, it is afraid of long-term dust accumulation and oil staining, so it has high requirements for the environment.

5. Capacitive sensing touch screen:

Since the capacitance varies with temperature, humidity or grounding conditions, it is not stable and tends to drift. It is afraid of electromagnetic field disturbance and drift, and is not easy to be used in industrial control places and local areas with disturbance. It can be used for public information queries that require less granularity; It needs to be calibrated and positioned frequently;
More on that
The main functions of the Xinjie touch screen and PLC control system The main functions of the Xinjie touch screen and PLC control system

(1) The entire control process works under the Chinese system, and the handling is completely Chinese (2) Realize the active control of batching, blanking, mixing and concrete displacement (3) The mixing time and blanking sequence can be adjusted immediately (4) Batching, blanking, mixing ...

Xinjie MS6 series high-performance servo motor is pleased to mention the 2020 "Automation Innovation Award - Motion Control Category" Xinjie MS6 series high-performance servo motor is pleased to mention the 2020 "Automation Innovation Award - Motion Control Category"

On March 19, 2021, the "Made in China Digital Service Summit 2021 CAIMRS and Annual Selection and Award Ceremony" held by China's industrial control network was broadcast live on the cloud of the "Industrial Control Network Digital Conference Hall". At the meeting, Pan Yingzhang, President of Gongkong®, officially released China's automation and digital ...

Inverter interference mode and treatment method - Xinjie Inverter interference mode and treatment method - Xinjie

Communication: (1) Radiation disturbance; (2) Conduction disturbance Anti-disturbing method: Regarding the disturbance signal transmitted by the radiation method, it is mainly weakened by wiring and shielding the radioactive source and the disturbed line. With regard to the disturbance signal transmitted through the line, ...

A brief description of the new model of Xinjie PLC A brief description of the new model of Xinjie PLC

1.XG1 series is the latest modular medium-sized PLC of Xinjie, aiming at the domestic high-end market. peculiarity Medium-sized series PLCs with powerful functions and larger storage capacity Support 4 channels of 200K high-speed pulse transmission ...

Introduction to Xinjie touch screen TP Introduction to Xinjie touch screen TP

1. Introduction TP Contact Industrial Graphic Displayer (referred to as contact screen) is a human-machine interface (known as HMI or MMI in foreign countries) that connects humans and machines (mainly PLC), which is known as the face of PLC. It is a generation ...

The reason why the inverter damages the motor bearing - Xinjie The reason why the inverter damages the motor bearing - Xinjie

The damage of the inverter to the motor contains two aspects, the damage of the stator winding and the damage of the bearing, this damage usually occurs in a few weeks to more than ten months, the detailed moment and the inverter brand, the motor brand, the motor power, the inverter carrier frequency, the cable length between the inverter and the motor, the ring ...

Attention to the solution of heat dissipation in the application of inverter - Xinjie Attention to the solution of heat dissipation in the application of inverter - Xinjie

Assuming that the inverter has a long service life, heat dissipation must be carefully considered. Because the equipment failure rate of the inverter increases exponentially with the increase of temperature, the service life decreases. If the operating temperature rises by 10 degrees, the service life of the inverter will decrease. ...

The allowable length of the cable between the inverter and the motor - Xinjie The allowable length of the cable between the inverter and the motor - Xinjie

The voltage waveform output by the inverter is similar to a sine wave, but not a real sine wave. Its waveform contains a large number of harmonic components, especially the higher harmonics will increase the output current of the inverter, form the motor winding heating, produce vibration and noise, accelerate the aging of insulation, and even ...

The characteristics of the inverter in the process of development - Xinjie The characteristics of the inverter in the process of development - Xinjie

The frequency converter is a power converter in the motion control system. Today's motion control system includes many technical fields, and the general development trend is: communication drive, high-frequency power changer, digital, intelligent, and networked control. VFDs are power converters in motion control systems. ...

The difference between PLC and PAC - Xinjie The difference between PLC and PAC - Xinjie

PLC is the abbreviation of programmable logic manipulator, which is a digital operation manipulator with a microprocessor for automatic control, which can load control instructions into memory at any time for storage and fulfillment. PAC is an abbreviation for Programmable Automation Manipulator. PAC in industrial control ...

The main role and function of TP touch screen The main role and function of TP touch screen

The primary role of the TP contact screen Supervision: Reflect the internal bit status of the PLC in various ways such as data, curves, graphics, animations, etc., store the numerical value, and then intuitively reflect the process and direction of the industrial control system. Exercise...

Advantages and opportunities of domestic PLC - Xinjie Advantages and opportunities of domestic PLC - Xinjie

At present, in the domestic PLC market, there are many kinds, but there are not many domestic PLC manufacturers with real strength, most of the domestic PLC is not an individual who does not have the qualification of a legal person, or a single-chip microcomputer enthusiast, from the domestic PLC factory to buy the underlying programming code or buy a domestic PLC chip (the domestic P that burns the underlying code...

Introduction to the configuration method of inverter - Xinjie inverter Introduction to the configuration method of inverter - Xinjie inverter

1. Acknowledging the characteristics of the load such as load type, speed, and nature; 2. Acknowledging whether it is continuous work, long-term work, short-term work and other work characteristics; 3. Acknowledging the maximum consumption output value and the extra output value; 4. Acknowledging ...

The risk cost of using the inverter - Xinjie The risk cost of using the inverter - Xinjie

When we select the right inverter brand, we need to recognize whether it can help enterprises better manage the risks and costs caused by potential safety, security and downtime accidents. Safety: Reverse arc drives assist users in meeting stringent reverse arc specifications. These inverters (Variabl ...

Learn PLC programming skills - Xinjie PLC Learn PLC programming skills - Xinjie PLC

1. When the PLC and the host computer (or touch screen) form a monitoring system, there are many times on the screen that there are "manual", "active" and other control modes (generally more than one). In the program, you can use the "MOV" command. For example, when selecting "manual", the constant 1MOV will be ...

Xinjie's new products won the "Innovative Product Award"! Xinjie's new products won the "Innovative Product Award"!

It is reported that after a comprehensive evaluation by the user expert jury, network users and gongkong, Xinjie's XDM-60T10-E motion control PLC won the "Innovative Product Award" in the 13th annual automation selection activity of gongkong. ...

Characteristics and composition of Xinjie tile programming system Characteristics and composition of Xinjie tile programming system

Tile programming features The editing and display mode in all Chinese greatly improves the readability of the program; Customizable programming instructions. Not only can the name of the instruction be modified according to the characteristics of the industry, but also the instruction can be added or deleted according to the needs of the equipment; Adopt a procedural editing mode. ...

Introduction of Xinjie PLC inverter visual system Introduction of Xinjie PLC inverter visual system

XC can be divided into multiple sub-series according to the incompatibility of functions, including XC1 (economy), XC2 (foundation), XC3 (standard), XC5 (enhanced) and their corresponding expansion modules, as well as special imitation ontology, activity control models, etc. Powerful function, complete variety, can be full ...

Precautions for PLC circuit debugging - Xinjie Precautions for PLC circuit debugging - Xinjie

1. For the switching input and output circuits, pay attention to the consistency criterion of maintaining the situation; The positive logic criterion is usually used, that is, when the input and output are live, it is the "ON" state and the data value is "1"; On the other hand, when the input and output are powered off, it is in the "OFF" state and the data value is "0". Such...

PLC input and output circuit debugging - Xinjie PLC input and output circuit debugging - Xinjie

1. Analog input (AI) loop debugging. Carefully check the address assignment of the I0 module; Check whether the loop power supply method (internal or external) is consistent with the field instrument; Use a signal generator to check the participating signals of each channel at the field end, generally taking three points of 0, 50% or 100%. ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top