1. On the premise of satisfying the production equipment and process requirements, the acceleration or deceleration time should be increased as much as possible, and then the overcurrent generation in the process of acceleration or deceleration can be avoided.
2. Check whether the inverter, motor, and production equipment are well matched, whether the transmission part is sensitive, and whether the material is stuck.
3. Whether the inverter itself is defective. Whether the three-phase voltage balance meets the requirements, if not, check whether the driving waveform of the inverter is normal. In other inverters, such as Danfoss products, the current detection link is faulty, and overcurrent will also appear. However, some brands of inverters, even if there is a problem with the current detection link, do not show overcurrent, which should be paid attention to in use. If there is a problem with the inverter main circuit device of the inverter, it will also present an overcurrent phenomenon.
4. When the output cable of the inverter is lengthened, the high-frequency loss is increased, so that the output of the inverter is not good, and the following two methods should be used to deal with this problem.
(1) Make some modifications to the parameters of the inverter. In the case of agreeing conditions, the output carrier frequency of the inverter can be modified, the output frequency can be reduced, and the high-frequency loss can be reduced. In addition, the output torque can be increased to reduce the effect of high-frequency losses.
(2) An AC reactor can be added at the output end of the inverter to suppress the sudden change of current and prevent overcurrent. For the selection of reactors, you can contact the inverter manufacturer to select the reactor with the power. Others can also be consulted for the relevant materials to design by themselves.
In short, there are many reasons for the overcurrent of the inverter, which should be analyzed and dealt with according to the specific situation. If the inverter often generates overcurrent, and it is confirmed that it is caused by overload, a higher-grade inverter can be used to overcome the overcurrent caused by overload.
|
More on that
|
Xinjie launched the wireless transparent transmission module S-BOX-T
Wireless module introduction:
W-BOX-T: Wireless WIFI module, XC, XD series can be used, occupying RS232 port;
S-BOX-T S-BOX: 433MHZ MODULE, XC AND XD SERIES CAN BE USED, OCCUPYING RS232 PORT;
XD-E1WT-A ...
|
|
Fault distribution of PLC control system - Xinjie
In order to shorten the early problem period, further extend the random problem period, and postpone the arrival of the wear and tear problem period, we will generally choose the method to take a certain approach at the beginning of the system planning.
|
|
PLC and inverter shielded wire connection method - Xinjie
In order to prevent the control signal line between the PLC and the inverter from being disturbed by the space electromagnetic field, the outer layer of these control signal lines can be connected with shielded wires to improve the anti-interference ability of the system. This kind of wiring must be noted, and only one point can be selected for the shielded connection address. Whether it's on the PLC side, or ...
|
|
Internal causes and preventive measures of inverter failure
The problem of the inverter is not only affected by external factors, but also by internal factors.
1. The inverter parameter setting is unreasonable and countermeasures to make the inverter work normally, in addition to the normal equipment, the parameter setting is also very important, if the parameter is not set properly, it will not be able to ...
|
|
Advantages of using motor soft starter - Xinjie
The motor soft starter is a new type of starting equipment designed and produced by using power electronics skills, microprocessing skills and modern control theory.
The motor soft starter can effectively limit the starting current of the AC asynchronous motor when starting, and can be widely used in wind ...
|
|
How to properly ground the PLC - Xinjie PLC
The grounding policy is nothing more than to avoid disturbance for safety, and the policy of grounding to PLC must not be attached to the disturbance at the power supply and input and output terminals, so the accurate grounding system is one of the primary methods for the PLC control system to resist electromagnetic disturbance. There are floating and direct grounding formations.
|
|
Small PLC manufacturers introduce the classification of PLC - Xinjie
Small PLC manufacturers introduce that PLC products have a wide variety of products, and the specifications and performance are also different. The classification of PLCs is usually based on their structure, function and number of I/O points.
1. Classified by input/output points
(1) ...
|
|
The development status of human-computer interface shopping malls in China
The development status of human-computer interface shopping malls in China
China is the shopping mall with the largest demand for human-computer interface in the world, but it is not the shopping mall with the highest sales of human-computer interface products in the world.
|
|
The allowable length of the cable between the inverter and the motor - Xinjie
The voltage waveform output by the inverter is similar to a sine wave, but not a real sine wave. Its waveform contains a large number of harmonic components, especially the higher harmonics will increase the output current of the inverter, form the motor winding heating, produce vibration and noise, accelerate the aging of insulation, and even ...
|
|
Superheat treatment method of Xinjie inverter drive motor
Why does the motor driven by the inverter overheat? This is due to the fact that the voltage of the inverter drive motor contains a rich high-frequency component.
The voltage waveform of the inverter-driven motor is not a sine wave voltage, but a pulse-width modulation (PWM) voltage. According to Fu Liye's analysis, this waveform ...
|
|
The difference between the models of Xinjie TG series touch screen
The suffix is XT and only supports RS232 communication, 4 inches out.
The suffix MT supports RS 232/485/422 communication.
The suffix is UT on the basis of MT, and a U disk port is added, which can be used to import and export engineering and CSV data from U disk.
The suffix is named ET and is added to the UT ...
|
|
Xinjie inverter maintenance method
In the instruction manual of the inverter, there is a column that discusses in detail the fault code display of the inverter.
1. Short-circuit maintenanceIf there is short-circuit maintenance on the side of the inverter's operation, "0" means that the inverter has short-circuit elements inside or outside. There are several reasons for this ...
|
|
The cause of abnormal noise of PLC input and output module - Xinjie
Input and output module, if it is the kind of relay output, it is normal to have a little movement, because the relay is a mechanical equipment, there will be a little noise during the action, but the average person can not hear it, if it is obvious, it is estimated that the relay is broken, such as a short circuit between the turns of the coil, please pay attention to: Rongji point ...
|
|
Xinjie developed professional solutions for sealing lines
Introduction to the glass sealing industry
As a relatively old industry, the vitality of the glass industry has further burst out in the modern society, due to the social development and the improvement of people's aesthetics, the demand for glass in all walks of life is also increasing, which is also more abundant.
|
|
The safety standard of the inverter - Xinjie
World electrical safety standards: The requirements are in line with the world's electrical safety standards, such as the CE standard in Europe and the UL standard in the United States. These specifications specify the requirements for electrical safety functions, mechanical safety functions, EMC functions, etc.
Machine...
|
|
Xinjie in a nutshell!
As the only domestic brand among the top 10 small PLC shopping malls in China, Xinjie has broken through the core shopping malls dominated by international brands for more than ten years, and the unswerving commitment of the leader Li Xin to independent development can be seen.
...
|
|
The application of Xinjie PLC in central air conditioning
One. How the system works
The fresh air blown in by the fresh fan enters the room through the heating exchanger, refrigeration exchanger, and humidifier. In the room, the signals measured by the temperature, humidity, and differential pressure detectors are reflected to the controller. The heating and refrigeration exchanger is controlled by a digital manipulator by a reaction signal ...
|
|
Leakage analysis of inverter-controlled motor - Xinjie
Because the current at the input and output ends of the inverter contains high-frequency components, the leakage current formed by the high-frequency components when the inverter is driven is greater than that when the grid power supply is supplied. Because there are many varieties of circuit breakers, in some cases, even the inverter wires and motors ...
|
|
Differential amplifier overhaul method of Xinjie inverter
Problem example 1
On the telegram OC problem, measure the 5, 6, and 7 pins of N1 to be 2V. Pin 7 is not 0V for the alarm reason.
1. The "imaginary short" rule of the amplifier is still established, and the N1 chip is good to judge, but the fault is in the bias circuit.
2. Further analysis, at this moment the differential amplifier has ...
|
|
Xinjie touch screen features and advantages
Xinjie touch screen is an extraordinary technology product developed by Xinjie Technology Company. It not only uses touchscreen skills, but also integrates cutting-edge skills in many fields such as human-computer interaction, visual arts, and information processing, bringing skills to users.
...
|
|