1.XG1 series is the latest modular medium-sized PLC of Xinjie, aiming at the domestic high-end market.
peculiarity
Medium-sized series PLCs with powerful functions and larger storage capacity
It supports 4 channels of 200K high-speed pulse output, 4 channels of AB phase 50KHz, and single-phase 80KHz high-speed counting
It supports two-axis linkage (linear and arc) interpolation, 3-way follow-up, 20-axis X-NET motion bus and fieldbus functions
XG1-16T4-C host 8 input/8 output, transistor output, DC24V power supply
Support USB port high-speed download, speed up to 12M
Up to 16 expansion modules can be connected
The CPU processing speed has been improved to about 30 times that of the XC series and twice that of the XD
Supports PID, external interrupts, C-function function blocks, basic logic control, and data operations
It supports Ethernet (RJ45) communication, X-NET fieldbus, MODBUS communication and other functions
With clock and power-down hold for data
2. XL3 series is a new type of ultra-thin PLC launched by Xinjie.
peculiarity
Slim PLC, small and practical, saving installation space
It supports 2 channels of high-speed pulse output (T-type support) and 3 channels of AB phase high-speed counting
8/16 inputs, 8/16 outputs, transistor/relay outputs, DC24V power supply
Up to 10 expansion modules and 1 ED module can be connected
Support USB port high-speed download
It has a higher processing speed, about 12 times that of the XC series
With clock and power-down hold for data
Supports basic logic control and data operations
It supports X-NET fieldbus, PID, external interrupt, C-function function block, MODBUS communication and other functions
3. Xinjie plc currently has XC series, XD series, XE series, XL3 series, XG1 series, etc.
|
More on that
|
Internal interference in PLC remote module system - Xinjie
The internal disturbances of the PLC system are mainly caused by the mutual electromagnetic radiation between the internal components and circuits of the system, such as the mutual radiation of logic circuits and their influence on the imitation circuit, the interaction between imitation and logic, and the mutual mismatch between components. How to deal with PLC long distances ...
|
|
Introduction to PLC components - Xinjie
1、CPU。 The CPU of the plc is actually the central processing unit, which can carry out the operation and processing of various data, convert various input signals into input registers, and then carry out logical operations, timing, counting, arithmetic operations, data processing and transmission, communication networking and various operations, ...
|
|
Xinjie PLC problems and solutions
Xinjie PLC 丨Communication failure is generally summarized as the following problems:
(1) Communication parameters: The communication parameters of Xinjie PLC communication port and peripheral equipment may be inconsistent.
(2) Communication line: The connection may be incorrect, or the contact is poor, the user can replace the communication line and try again.
|
|
Interference within the PLC remote module system - Xinjie PLC
The internal disturbance of the PLC system is mainly caused by the mutual electromagnetic radiation between the components and circuits inside the system, such as the mutual radiation of logic circuits and their influence on the imitation circuit, the interaction between the imitation ground and the logical ground and the mutual mismatch between components. How to deal with PLC long distances effectively ...
|
|
The characteristics of the inverter in the process of development - Xinjie
The frequency converter is a power converter in the motion control system. Today's motion control system includes many technical fields, and the general development trend is: communication drive, high-frequency power changer, digital, intelligent, and networked control.
VFDs are power converters in motion control systems. ...
|
|
Attention to the solution of heat dissipation in the application of inverter - Xinjie
Assuming that the inverter has a long service life, heat dissipation must be carefully considered. Because the equipment failure rate of the inverter increases exponentially with the increase of temperature, the service life decreases. If the operating temperature rises by 10 degrees, the service life of the inverter will decrease.
...
|
|
Xinjie inverter maintenance method
In the instruction manual of the inverter, there is a column that discusses in detail the fault code display of the inverter.
1. Short-circuit maintenanceIf there is short-circuit maintenance on the side of the inverter's operation, "0" means that the inverter has short-circuit elements inside or outside. There are several reasons for this ...
|
|
Normal selection and matching of inverter - Xinjie
We want to make sure that the capacity of the inverter is matched. First of all, according to the nature of the load, the correct type of inverter is selected. The general criterion is what is the nature of the load characteristics with what characteristics of the inverter, the following is mainly for pumps and other equipment to clarify.
...
|
|
The constituent department of PLC control cabinet - Xinjie PLc
1. Air opening: a total air switch, which is the power control of the entire cabinet. I believe that every cabinet must have one thing.
2. PLC: This should be selected according to the needs of the project. For example, if the project is small, it can be an integrated PLC, but if the project is more ...
|
|
The risk cost of using the inverter - Xinjie
When we select the right inverter brand, we need to recognize whether it can help enterprises better manage the risks and costs caused by potential safety, security and downtime accidents.
Safety: Reverse arc drives assist users in meeting stringent reverse arc specifications. These inverters (Variabl ...
|
|
The role of motion control for inverters - Xinjie
Motion control has a significant period characteristic, it is a variety of high-tech generalization, used to bring industrial automation, office automation and home automation to a higher stage. Nowadays, motion control is mainly composed of variable frequency drive (VFD), electric motor, control ...
|
|
Xinjie launched the wireless transparent transmission module S-BOX-T
Wireless module introduction:
W-BOX-T: Wireless WIFI module, XC, XD series can be used, occupying RS232 port;
S-BOX-T S-BOX: 433MHZ MODULE, XC AND XD SERIES CAN BE USED, OCCUPYING RS232 PORT;
XD-E1WT-A ...
|
|
Xinjie touch screen features and advantages
Xinjie touch screen is an extraordinary technology product developed by Xinjie Technology Company. It not only uses touchscreen skills, but also integrates cutting-edge skills in many fields such as human-computer interaction, visual arts, and information processing, bringing skills to users.
...
|
|
Xinjie WIFI wireless communication module W-BOX
W-BOX is a 2.4GHzWifi-based wireless communication module independently developed and recently launched by Xinjie in line with the trend of wireless communication. W-BOX can be connected with wireless AP (hotspot) in various occasions to complete long-distance monitoring of PLC and overall control of PLC wireless networking in various environments.
|
|
PLC communication interface failure and solution——Xinjie
1. Common problem phenomena
When the RS-485 port of the PLC is connected to the computer through the non-blocking PC/PPI cable, the connection between the PLC and the PLC, or the communication between the PLC and the inverter, touch screen, etc., the communication port is damaged, and the more common damage conditions are as follows:
(1) R1 or R2 is burned ...
|
|
XDH | XLH series of 16-axis high-performance EtherCAT controllers
The XDHI XLH series of 16-axis high-performance EtherCAT controllers is the perfect choice for small motion control.
Product model
XDH-30A16-E/XDH-30A16L-E Small/16-axis type
Frequency: 600MHz
Program Capacity: ...
|
|
Small PLC manufacturers introduce the classification of PLC - Xinjie
Small PLC manufacturers introduce that PLC products have a wide variety of products, and the specifications and performance are also different. The classification of PLCs is usually based on their structure, function and number of I/O points.
1. Classified by input/output points
(1) ...
|
|
Precautions for installation of Xinjie servo motor
The MS series of servo motors can be installed in either the horizontal or vertical direction. However, if it is installed incorrectly, or in an unsuitable place, it can shorten the life of the motor or cause unexpected accidents.
Storage temperature
In the unpowered state ...
|
|
The inverter controls the leakage of the motor
Because the current at the input and output ends of the inverter contains high-frequency components, the leakage current formed by the high-frequency components when the inverter is driven is greater than that when the grid power supply is supplied. Because there are many varieties of circuit breakers, in some cases, even the inverter wires and motors ...
|
|
PLC input and output circuit debugging - Xinjie
1. Analog input (AI) loop debugging. Carefully check the address assignment of the I0 module; Check whether the loop power supply method (internal or external) is consistent with the field instrument; Use a signal generator to check the participating signals of each channel at the field end, generally taking three points of 0, 50% or 100%. ...
|
|