A brief description of the new model of Xinjie PLC

Create Date: 2024-8-30 12:03:23|Source: XINJE

1.XG1 series is the latest modular medium-sized PLC of Xinjie, aiming at the domestic high-end market.

                               A brief description of the new model of Xinjie PLC

peculiarity

Medium-sized series PLCs with powerful functions and larger storage capacity

It supports 4 channels of 200K high-speed pulse output, 4 channels of AB phase 50KHz, and single-phase 80KHz high-speed counting

It supports two-axis linkage (linear and arc) interpolation, 3-way follow-up, 20-axis X-NET motion bus and fieldbus functions

XG1-16T4-C host 8 input/8 output, transistor output, DC24V power supply

Support USB port high-speed download, speed up to 12M

Up to 16 expansion modules can be connected

The CPU processing speed has been improved to about 30 times that of the XC series and twice that of the XD

Supports PID, external interrupts, C-function function blocks, basic logic control, and data operations

It supports Ethernet (RJ45) communication, X-NET fieldbus, MODBUS communication and other functions

With clock and power-down hold for data

2. XL3 series is a new type of ultra-thin PLC launched by Xinjie.

peculiarity

Slim PLC, small and practical, saving installation space

It supports 2 channels of high-speed pulse output (T-type support) and 3 channels of AB phase high-speed counting

8/16 inputs, 8/16 outputs, transistor/relay outputs, DC24V power supply

Up to 10 expansion modules and 1 ED module can be connected

Support USB port high-speed download

It has a higher processing speed, about 12 times that of the XC series

With clock and power-down hold for data

Supports basic logic control and data operations

It supports X-NET fieldbus, PID, external interrupt, C-function function block, MODBUS communication and other functions

3. Xinjie plc currently has XC series, XD series, XE series, XL3 series, XG1 series, etc.
More on that
Internal interference in PLC remote module system - Xinjie Internal interference in PLC remote module system - Xinjie

The internal disturbances of the PLC system are mainly caused by the mutual electromagnetic radiation between the internal components and circuits of the system, such as the mutual radiation of logic circuits and their influence on the imitation circuit, the interaction between imitation and logic, and the mutual mismatch between components. How to deal with PLC long distances ...

Introduction to PLC components - Xinjie Introduction to PLC components - Xinjie

1、CPU。 The CPU of the plc is actually the central processing unit, which can carry out the operation and processing of various data, convert various input signals into input registers, and then carry out logical operations, timing, counting, arithmetic operations, data processing and transmission, communication networking and various operations, ...

Xinjie PLC problems and solutions Xinjie PLC problems and solutions

Xinjie PLC 丨Communication failure is generally summarized as the following problems: (1) Communication parameters: The communication parameters of Xinjie PLC communication port and peripheral equipment may be inconsistent. (2) Communication line: The connection may be incorrect, or the contact is poor, the user can replace the communication line and try again.

Interference within the PLC remote module system - Xinjie PLC Interference within the PLC remote module system - Xinjie PLC

The internal disturbance of the PLC system is mainly caused by the mutual electromagnetic radiation between the components and circuits inside the system, such as the mutual radiation of logic circuits and their influence on the imitation circuit, the interaction between the imitation ground and the logical ground and the mutual mismatch between components. How to deal with PLC long distances effectively ...

The characteristics of the inverter in the process of development - Xinjie The characteristics of the inverter in the process of development - Xinjie

The frequency converter is a power converter in the motion control system. Today's motion control system includes many technical fields, and the general development trend is: communication drive, high-frequency power changer, digital, intelligent, and networked control. VFDs are power converters in motion control systems. ...

Attention to the solution of heat dissipation in the application of inverter - Xinjie Attention to the solution of heat dissipation in the application of inverter - Xinjie

Assuming that the inverter has a long service life, heat dissipation must be carefully considered. Because the equipment failure rate of the inverter increases exponentially with the increase of temperature, the service life decreases. If the operating temperature rises by 10 degrees, the service life of the inverter will decrease. ...

Xinjie inverter maintenance method Xinjie inverter maintenance method

In the instruction manual of the inverter, there is a column that discusses in detail the fault code display of the inverter.   1. Short-circuit maintenanceIf there is short-circuit maintenance on the side of the inverter's operation, "0" means that the inverter has short-circuit elements inside or outside. There are several reasons for this ...

Normal selection and matching of inverter - Xinjie Normal selection and matching of inverter - Xinjie

We want to make sure that the capacity of the inverter is matched. First of all, according to the nature of the load, the correct type of inverter is selected. The general criterion is what is the nature of the load characteristics with what characteristics of the inverter, the following is mainly for pumps and other equipment to clarify. ...

The constituent department of PLC control cabinet - Xinjie PLc The constituent department of PLC control cabinet - Xinjie PLc

1. Air opening: a total air switch, which is the power control of the entire cabinet. I believe that every cabinet must have one thing. 2. PLC: This should be selected according to the needs of the project. For example, if the project is small, it can be an integrated PLC, but if the project is more ...

The risk cost of using the inverter - Xinjie The risk cost of using the inverter - Xinjie

When we select the right inverter brand, we need to recognize whether it can help enterprises better manage the risks and costs caused by potential safety, security and downtime accidents. Safety: Reverse arc drives assist users in meeting stringent reverse arc specifications. These inverters (Variabl ...

The role of motion control for inverters - Xinjie The role of motion control for inverters - Xinjie

Motion control has a significant period characteristic, it is a variety of high-tech generalization, used to bring industrial automation, office automation and home automation to a higher stage. Nowadays, motion control is mainly composed of variable frequency drive (VFD), electric motor, control ...

Xinjie launched the wireless transparent transmission module S-BOX-T Xinjie launched the wireless transparent transmission module S-BOX-T

   Wireless module introduction: W-BOX-T: Wireless WIFI module, XC, XD series can be used, occupying RS232 port; S-BOX-T S-BOX: 433MHZ MODULE, XC AND XD SERIES CAN BE USED, OCCUPYING RS232 PORT; XD-E1WT-A ...

Xinjie touch screen features and advantages Xinjie touch screen features and advantages

Xinjie touch screen is an extraordinary technology product developed by Xinjie Technology Company. It not only uses touchscreen skills, but also integrates cutting-edge skills in many fields such as human-computer interaction, visual arts, and information processing, bringing skills to users. ...

Xinjie WIFI wireless communication module W-BOX Xinjie WIFI wireless communication module W-BOX

W-BOX is a 2.4GHzWifi-based wireless communication module independently developed and recently launched by Xinjie in line with the trend of wireless communication. W-BOX can be connected with wireless AP (hotspot) in various occasions to complete long-distance monitoring of PLC and overall control of PLC wireless networking in various environments.

PLC communication interface failure and solution——Xinjie PLC communication interface failure and solution——Xinjie

1. Common problem phenomena When the RS-485 port of the PLC is connected to the computer through the non-blocking PC/PPI cable, the connection between the PLC and the PLC, or the communication between the PLC and the inverter, touch screen, etc., the communication port is damaged, and the more common damage conditions are as follows: (1) R1 or R2 is burned ...

XDH | XLH series of 16-axis high-performance EtherCAT controllers XDH | XLH series of 16-axis high-performance EtherCAT controllers

The XDHI XLH series of 16-axis high-performance EtherCAT controllers is the perfect choice for small motion control. Product model XDH-30A16-E/XDH-30A16L-E Small/16-axis type Frequency: 600MHz Program Capacity: ...

Small PLC manufacturers introduce the classification of PLC - Xinjie Small PLC manufacturers introduce the classification of PLC - Xinjie

Small PLC manufacturers introduce that PLC products have a wide variety of products, and the specifications and performance are also different. The classification of PLCs is usually based on their structure, function and number of I/O points. 1. Classified by input/output points (1) ...

Precautions for installation of Xinjie servo motor Precautions for installation of Xinjie servo motor

The MS series of servo motors can be installed in either the horizontal or vertical direction. However, if it is installed incorrectly, or in an unsuitable place, it can shorten the life of the motor or cause unexpected accidents.   Storage temperature In the unpowered state ...

The inverter controls the leakage of the motor The inverter controls the leakage of the motor

Because the current at the input and output ends of the inverter contains high-frequency components, the leakage current formed by the high-frequency components when the inverter is driven is greater than that when the grid power supply is supplied. Because there are many varieties of circuit breakers, in some cases, even the inverter wires and motors ...

PLC input and output circuit debugging - Xinjie PLC input and output circuit debugging - Xinjie

1. Analog input (AI) loop debugging. Carefully check the address assignment of the I0 module; Check whether the loop power supply method (internal or external) is consistent with the field instrument; Use a signal generator to check the participating signals of each channel at the field end, generally taking three points of 0, 50% or 100%. ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top