In order to shorten the early problem period, further extend the random problem period, and delay the arrival of the wear and tear problem period, we will generally choose the method to take a certain approach at the beginning of the system planning, and replace the components that enter the wear and tear problem problem before the arrival of the wear and tear problem period. Of course, in order to better find the location of the problem and do the above work well, it is important to have a considerable understanding of the parts where the problem is scattered. The spread of the questions is generally as follows:
(1) External faults
The external problems of the control system refer in detail to the various switches, actuators, sensors and loads and other equipment that are directly connected in the actual working process. When this part of the equipment has problems, it will generally directly affect the relevant control functions of the system, and the cause of the problem is generally the quality problem of the equipment itself or the reason for the life of the device.
(2) System failure
The problem of the system is the overall problem of the operation of the system. System problems are divided into fixed problems and contingent problems. Accidental problems refer to the fact that after the problem occurs, it can be restarted to restore the system to normal; Qualitative problems refer to the fact that after the problem is generated, the reboot cannot be repaired and the hardware or software needs to be replaced before the system can be restored normally. Fixity problems are generally caused by improper system planning or the long number of years of operation of the system.
(3) Hardware failure
In the control system, the hardware problem mainly refers to the problem caused by the damage of the template of the system, which is generally significant, and the impact is also local, and the reason for this problem is that the equipment is used for a long time in the process of use, and the elements of the template are aged.
(4) Software failures
Software problems are caused by the faults of the software itself, mainly due to poor planning of the software, which can be caused by the satisfaction of the conditions in the hospitality. In the total system problems, only 5% of the problems occur in the PLC, which shows that the reliability of the PLC itself is much higher than the reliability of external equipment. Among the 5% problems of the PLC, 90% of the problems are generated in the FO template, and only 10% of the problems are generated in the controller, that is to say, the problems generated in the CPU, memory, system bus and power supply of the PLC account for only 5% of the total problems of the system, and the problems generated in the FO template only account for 5% of the total problems of the system.
|
More on that
|
The allowable length of the cable between the inverter and the motor - Xinjie
The voltage waveform output by the inverter is similar to a sine wave, but not a real sine wave. Its waveform contains a large number of harmonic components, especially the higher harmonics will increase the output current of the inverter, form the motor winding heating, produce vibration and noise, accelerate the aging of insulation, and even ...
|
|
PLC and inverter shielded wire connection method - Xinjie
In order to prevent the control signal line between the PLC and the inverter from being disturbed by the space electromagnetic field, the outer layer of these control signal lines can be connected with shielded wires to improve the anti-interference ability of the system. This kind of wiring must be noted, and only one point can be selected for the shielded connection address. Whether it's on the PLC side, or ...
|
|
Advantages of Xinjie XDM series motion control PLC
Xinjie XDM series PLC, XDM is the sports control PLC in the XD series, now has the following types: XDM-24T4-E/C, XDM-32T4-E/C, XDM-60T4-E/C, XDM-60T10-E/C.
The XDM series has the following ...
|
|
Xinjie inverter control mode
The output voltage of low-voltage general frequency conversion is 380-650V, the output power is 0.75-400kW, and the working frequency is 0-400Hz. Its control methods have gone through the following four generations.
1U/f=C Sine Pulse Width Modulation (SPWM) Control Method ...
|
|
Introduction of Xinjie PLC inverter visual system
XC can be divided into multiple sub-series according to the incompatibility of functions, including XC1 (economy), XC2 (foundation), XC3 (standard), XC5 (enhanced) and their corresponding expansion modules, as well as special imitation ontology, activity control models, etc. Powerful function, complete variety, can be full ...
|
|
The Xinjie touch screen screen production system includes the project
The creation of the touch screen screen is done by TouchWin editing tool software. Each screen includes each control menu and video window, and the home page can be written by the relevant units to write the advertising screen welcome speech or system model description. The system mainly includes the following items:
...
|
|
Common problems and solutions of Xinjie PLC
1. Why can't the PLC communicate with the peripherals?
Communication failures are generally summarized as the following problems:
1. Communication cable: The connection may be incorrect, or the contact is poor, the user can change the communication cable and try again.
2. Communication parameters: PLC communication port and peripheral equipment ...
|
|
The principle of PLC control servo motor - Xinjie
Control principle: PLC controls the operation of the servo motor by controlling the servo motor.
1. The PLC sends a pulse signal to the servo motor driver, pay attention to the driver.
2. The servo motor drive according to the ...
|
|
Characteristics and composition of Xinjie tile programming system
Tile programming features
The editing and display mode in all Chinese greatly improves the readability of the program;
Customizable programming instructions. Not only can the name of the instruction be modified according to the characteristics of the industry, but also the instruction can be added or deleted according to the needs of the equipment;
Adopt a procedural editing mode. ...
|
|
Xinjie PLC cable design selection and construction anti-interference measures
(1) The analog signal is a small signal, which is very susceptible to external interference, and a double-layer shielded cable should be selected;
(2) High-speed pulse signals (such as pulse sensors, digital disks, etc.) should be shielded cables, not only to prevent external interference, but also to prevent high-speed pulse signals from low-power.
|
|
Xinjie inverter maintenance method
In the instruction manual of the inverter, there is a column that discusses in detail the fault code display of the inverter.
1. Short-circuit maintenanceIf there is short-circuit maintenance on the side of the inverter's operation, "0" means that the inverter has short-circuit elements inside or outside. There are several reasons for this ...
|
|
Normal selection and matching of inverter - Xinjie
We want to make sure that the capacity of the inverter is matched. First of all, according to the nature of the load, the correct type of inverter is selected. The general criterion is what is the nature of the load characteristics with what characteristics of the inverter, the following is mainly for pumps and other equipment to clarify.
...
|
|
PLc installation and wiring requirements - Xinjie
(1) The PLC shall be installed in an environment that meets the requirements of the rules.
(2) In order to facilitate ventilation and disassembly, a space of more than 80mm should be left around the PLC.
(3) PLC should be a vertical device and not a horizontal device, that is, the device universal is the direction in which the words on the unit panel can be read normally, otherwise the PLC ...
|
|
Inverter technology strategy in electromechanical control
In the process of century industry, the more top-level software and hardware planning for the suspension of frequency conversion skills, first according to the characteristics of traditional air compressor motors, comprehensively analyze the causes of energy consumption and operation characteristics, so as to plan the control of frequency conversion skills speed regulation, air skill tightening, pressure sensing skills improvement, etc.
|
|
Diagram of the wiring of the servo motor of Xinjie
|
|
The role of motion control for inverters - Xinjie
Motion control has a significant period characteristic, it is a variety of high-tech generalization, used to bring industrial automation, office automation and home automation to a higher stage. Nowadays, motion control is mainly composed of variable frequency drive (VFD), electric motor, control ...
|
|
The 3rd National Industrial Robot Technology Application Skills Competition - Xinjie
On October 18, the final of the "2019 China Technology Competition - The 3rd National Industrial Robot Technology Use Technology Competition" sponsored by the Ministry of Industry and Information Technology, the Ministry of Human Resources and Social Security, the Ministry of Education, the All-China Federation of Trade Unions and the Central Committee of the Communist Youth League was officially opened in Jinan, Shandong Province.
|
|
Xinjie PLC inverter visual system
XC can be divided into multiple sub-series according to the incompatibility of functions, including XC1 (economy), XC2 (foundation), XC3 (standard), XC5 (enhanced) and their corresponding expansion modules, as well as special imitation ontology, activity control models, etc. Powerful function, complete variety, can be full ...
|
|
Introduction to the configuration method of inverter - Xinjie inverter
1. Acknowledging the characteristics of the load such as load type, speed, and nature;
2. Acknowledging whether it is continuous work, long-term work, short-term work and other work characteristics;
3. Acknowledging the maximum consumption output value and the extra output value;
4. Acknowledging ...
|
|
Xinjie PLC failure and solution
Xinjie PLC conditions are established, why is the corresponding coil not in place? There are two possible reasons for this:
(1) The same coil may be used in multiple places to perform the double coil output, and when the double coil is output, the coil on the rear side will operate first.
(2) ...
|
|