1. The temperature setting is set by the knob, which is convenient and intuitive 2. It can be directly installed on the standard junction box on the wall.
3. Beautiful appearance and reliable performance.
4. The switch adopts toggle type, which feels comfortable and has a long life.
5. It can control two-wire or three-wire electric (ball) valve.
6. It can be used to control fan coil unit and electric (ball) valve or damper and other equipment.
7. The temperature sensing element of the bimetal large diaphragm box can ensure accurate temperature control as required.
8. The automatic hot and cold conversion can be controlled by the pipeline thermostat (referring to some models of thermostats).
9. Special functions:1. Overrun Stop 2. Safety Cover 3. Wall mounting for special installation needs.
10. All models of constant temperature have a heat premonitor, which can further improve the hot and cold temperature control.
|
More on that
|
RKC Level Gauge – How to properly use a plug-in float level gauge for level measurement
1. Select the appropriate level gauge
First of all, it is necessary to choose the appropriate level gauge. The following factors should be taken into account in the selection of a level gauge:
Measure the properties of the medium: e.g., temperature, pressure, viscosity, corrosiveness, etc.
Measuring range: i.e. the height range of the liquid ...
|
|
RKC converter - an introduction to the classification of converters
Analog-to-digital converters
The analog-to-digital converter comprises a first transmission circuit, which receives an input voltage and an output clock signal, which is phase-shifted, depending on the input voltage, and a second transmission circuit receives a reference voltage and an input clock signal, and outputs a reference clock signal, which ...
|
|
Causes and treatment methods of inverter overvoltage
1. According to the theory of cutting off the overvoltage, when the transformer is cut off, the current in the transformer inductance cannot be abruptly changed, and the stored magnetic field energy forms a vibration between the excitation inductance of the transformer and the ground capacitor, and the overvoltage occurs.
2. Transformer ...
|
|
RLC thermostat – the wiring method of the thermostat
1. Prepare the thermostat, wires, and thermal resistance, and print out the wiring diagram of the thermostat
2. Use wire strippers to strip off the wire skin, use crimping pliers, and press the wire end to the cold-pressed terminal.
3. Connect the 220V power supply to the inlet terminal of the thermostat, and connect the thermal resistance to the thermostat ...
|
|
Wiring method of the RKG thermostat
Take CD901 as an example,
L(1) pin to 220 volt live wire,
N(2) pin 220 volt neutral wire,
3,4 pins for the first output,
5,6 pins for the second output,
7, 8, 9 pins are alarm output,
Finally, the three pins are connected to thermocouples or PT100 ...
|
|
RRKC Thermostats – Considerations for Instrumentation Maintenance and Maintenance
There are many types of instrumentation and have a wide range of applications in many fields. Because of this, there are many problems with the failure of instruments in the process of use, so it is necessary to pay more attention to the repair and maintenance of instruments and meters, which can effectively improve the performance of instruments and meters, and can extend the performance of instruments and meters.
|
|
RKC Thermostats – How to Choose a Thermocouple?
The selection of thermocouples should be based on comprehensive considerations such as the operating temperature range, the required accuracy, the operating atmosphere, the performance of the measured object, the response time and the economic benefits.
1. Selection of measurement accuracy and temperature measurement range
1) The operating temperature is 1300-1800°C, and the accuracy is required to be more accurate than ...
|
|
RLC thermostats – the classification of thermostats and their detailed introduction
1. Sudden jump thermostat
The type of various sudden thermostats is collectively called KSD, such as KSD301, KSD302, etc., the thermostat is a new type of bimetal thermostat, mainly as a variety of electric heating products with overheat protection, generally connected with the thermal fuse in series, sudden temperature ...
|
|
RKC Thermostat How to properly select and use a pressure sensor
High-temperature melt pressure sensors, transmitters, and high-temperature melt pressure gauges are special equipment in extrusion processing.
On the production line, melt pressure sensors play an important role in improving melt quality, increasing production safety and protecting production equipment.
Use...
|
|
RK thermostat - classification and precautions for use of central air conditioning thermostat
1. The principle of central air conditioning thermostat
Mechanical thermostats can be divided into vapor pressure thermostats, liquid expansion thermostats, gas adsorption thermostats and metal expansion thermostats. Among them, the vapor pressure thermostat is divided into inflatable type, liquid-gas mixed type and liquid-filled type. Domestic...
|
|
RKC Thermostat Usage Warning
· Wiring warning:
- If the instrument fails or an error occurs, which can cause a system failure, install external protection circuits to prevent such accidents;
- To prevent damage or failure of the instrument, use appropriate fuses to protect the power cord and input/output cord from strong power shocks.
...
|
|
RRC thermostat - how to adjust the smart thermostat
1. Set temperature: Press the SET button to set or view the temperature set point. Press the SET button digital tube characters to start flashing, indicating that the instrument has entered the setting state, press the △ key to increase the set value, press the ▽ key to decrease the set value, long press the △ key or ▽ key The data will change rapidly, press the SET key again ...
|
|
Parameter setting operation of RLC temperature control table CH402
Model: CH402FS01-8*HN (for PECVD temperature control)
1) Single press SET: SV can be set (set temperature manually)
2) Press and hold the SET button for 2 seconds, ALI=1000 (absolute alarm temperature setting) and then press the SET button, ATU=1 (self-defining, self-interpreting a set of PID parameters) to exit ...
|
|
RHK thermostat - the thermostat shows the reasons for the deviation between the temperature and the actual temperature and the solution
The thermostat shows a nonlinear relationship between the temperature and the actual temperature deviation:
(1) The input type of the thermostat is selected incorrectly;
(2) There is no calibration or calibration error in the analog input;
(3) There is interference in the thermostat;
(4) There is interference with thermocouples;
(5) The use of quality is not ...
|
|
RHK thermostat – a rapid detection method for common air conditioner thermostats
1
Bellows or diaphragm air conditioner thermostat
Fault Symptom:
Poor contact or burning, resulting in the circuit cannot be connected; The frequent action of the contact arc and sticking causes the circuit to be unbreakable; Leakage of thermostat in the temperature sensing chamber, causing the contacts to fail to operate and lose control ...
|
|
How to set the parameters of the RKG thermostat - intelligent digital display controller?
1. First of all, the digital display should be installed on the cabinet, so the overall coordination should be considered, too large may not fit, too small to see the display numbers.
2. In addition, the large size of the instrument is generally more expandable, the same function price may be expensive, the small size of the instrument may be ...
|
|
RKC thermostat - introduction of three wiring methods of thermal resistance
1. The three wiring methods of Pt100 RTD are different in principle:
The two-wire system and the three-wire system are measured by the bridge method, and the relationship between the temperature value and the analog output value is given after ***. There is no bridge on the four wires, it is completely just sent with a constant current source, measured by a voltmeter, and the test is given after *** ...
|
|
RKC thermostat - common faults and solutions of temperature control instruments
1. Heating for a period of time, the temperature does not change. The ambient temperature of the site (e.g. room temperature 25°C) is displayed at all times.
In case of such failures, first check whether the SV value setting value is set, whether the 0UT indicator light of the meter is lit, and whether the No. 3 and No. 4 terminals of the meter with the "multimeter" are 12VD ...
|
|
What are the rich functions of RRKC thermostats – wall mounted thermostats?
The wall-mounted thermostat is an ultra-thin intelligent thermostat that integrates measurement, display, control, alarm, recording and other functions, which can realize accurate measurement and control of temperature, pressure, flow and other parameters. Available in three sizes of 5 inches, 7 inches and 9 inches, a total of 12 models are available ...
|
|
Technical characteristics of the RKC thermostat
The core control algorithm of the thermostat is PID control, P (Proportional) + I (Integral) integral + D (Differential) differential control. In addition to the traditional PID control algorithm, RKC also has ON-OFF control, self-tuning parameter control, adaptive parameter control and other algorithms, temperature control ...
|
|