RHK thermostat – a rapid detection method for common air conditioner thermostats

Create Date: 2024-8-30 12:03:23|Source: RKC

1

Bellows or diaphragm air conditioner thermostat

Fault Symptom:

Poor contact or burning, resulting in the circuit cannot be connected; The frequent action of the contact arc and sticking causes the circuit to be unbreakable; The thermostat in the temperature sensing chamber leaks, causing the contact to fail to operate and lose control.

Maintenance method:

After turning the knob of the air conditioner thermostat in the forward and opposite directions several times, use the multimeter R×l gear to measure the two terminals of the temperature controller in the on-on state, if the resistance value is very small, it indicates that the contact is normal; If the resistance is very large, it means that the contact contact is poor; If it doesn't, it may be a leak of the thermostat. Whether there is leakage can be first visually inspected, observe whether the sealing welding head of the temperature sensing head is broken, whether the temperature sensing package is damaged and cracked, whether there are bending marks of the temperature sensing tube, etc., and then put the temperature sensing package in warm water of 30-40-C to test whether the contact is closed, if the contact is still not closed. indicates that the thermostat in the temperature sensor package has been leaked; If the contact can be closed, then take out the temperature sensing bag from the water, and the contact is disconnected after being placed in a low temperature environment for a period of time, indicating that the temperature adjustment range of the thermostat is improper, and it can be corrected by the adjusting screw that adjusts the temperature range, turn L in the counterclockwise direction, and try again after 2 hidden I.

Fault Symptom:

After the air conditioner thermostat contacts are sticking due to ignition. The contacts cannot jump open automatically, and the compressor cannot be stopped.

Maintenance method:

Put the temperature sensor bag in the refrigerator (5-lO°C) of the double-door refrigerator, and measure whether the two-wire terminals of the temperature controller are disconnected. If you don't keep opening. Indicates that the contact is adhesive, and the contact can be mechanically forced to break with a flat screwdriver; If the contact can be jumped open, the temperature control range of the thermostat drifts and is low, and the temperature control range adjustment screw can be adjusted clockwise.

Fault Symptom:

Leakage of thermostat.

Maintenance method:

Use a hot towel to heat the thermostat and set the knob to the lowest temperature, and use a multimeter to measure whether the switch of the thermostat is turned on. If the switch doesn't work. This indicates that the thermostat has leaked, and the thermostat should be replaced with a new one.

  2

Thermostat for hot and cold air conditioners

The thermostat used in electric air conditioners has two sets of contact mechanisms (cold contacts and hot contacts) in the contact control box, and the same temperature sensing bellows is used to control the heat and cold. Its fault phenomenon and inspection method are basically the same as those of ordinary thermostats, but it should be noted that it should also be checked whether the cold and hot switching actions are sensitive, that is, the compressor circuit should be connected when the refrigeration position is connected, and the electric heater circuit should be connected when the heating position is made.

  3

Defrost air conditioner thermostat

The defrost temperature controller is an element installed in the control circuit of a thermal air conditioner specifically for switching the solenoid reversing valve. Its thermostat is placed on the coil of the heat exchanger on the outdoor side. When heating in winter, the frost layer of the outdoor side heat exchanger thickens so that the temperature is lower than a certain set value. Contact action of the defrost controller. Disconnect the solenoid directional valve. The original heating cycle is changed to a cooling cycle. There are two commonly used structural forms: one is the thermal bimetal sheet type: the other is the ordinary thermostat. The method of detection is to place the temperature sensing part in water or air at the corresponding temperature. Use a multimeter to measure whether the two terminals are disconnected or on. You can know the good and the bad. Thermal bimetal thermostats are also used for indoor side cold air control.

  4

Temperature sensing resistance

Electronic air-conditioning thermostats or microcomputer-controlled air-conditioners use thermistors as the temperature sensing element. A thermistor is a component whose resistance changes significantly with temperature. Thermistor for ten vertical measurement of return air temperature of air conditioner. It generally has a negative temperature coefficient characteristic: the resistance value decreases with increasing temperature. Specific to the thermistor used in a certain brand of abyss device, its resistance value changes with temperature is generally drawn into a chart in the random manual for testing, and the detection can be in a certain environment. Measurements are made with semiconductor thermometers and multimeters. When the thermistor is aging and the performance drifts, that is, the correspondence between temperature and resistance value changes, a new thermistor sensor should be replaced.
RHK thermostat – a rapid detection method for common air conditioner thermostats

More on that
Common faults in the use of RKC thermostat Pt100 RTD Common faults in the use of RKC thermostat Pt100 RTD

  PT100 RTD is a platinum RTD, which can be regarded as a more commonly used thermometer in the range of medium and low temperatures, and it has a wide range of uses, including medical, electric, industrial production, thermometers and other high-precision thermometers. But due to the range of use ...

Common faults and solutions of RKC temperature controllers Common faults and solutions of RKC temperature controllers

1. The power indication is normal, but the temperature controller has no screen display. Most of this fault is caused by the heating of the voltage regulator element (7805 or 7812) on the thermostat during long-term use, which leads to the breakpoint of the solder joint, and sometimes it is caused by the phenomenon of virtual soldering at the factory, and the main re-soldering can be done. 2. Temperature controller ...

The main technical indicators of RKC thermostat The main technical indicators of RKC thermostat

The main technical indicators of RKC thermostat · Input: various thermocouple (TC), RTD standard current and voltage signals (see input type table); · basic error: 0.5% of the input full-scale ±±1 word; · Resolution: 1°C, 0.1°C; ...

Features and technical specifications of RKG thermostats Features and technical specifications of RKG thermostats

peculiarity 1. Thermocouple, RTD, analog and other signals are freely input, and the range can be set freely. 2. The software adjusts the full degree, the cold end measures the temperature separately, the amplifier is self-stabilizing, and the display accuracy is better than 0.5%FS. 3. Fuzzy theory combined with traditional PID method, fast control ...

RLC thermostats – the classification of thermostats and their detailed introduction RLC thermostats – the classification of thermostats and their detailed introduction

1. Sudden jump thermostat The type of various sudden thermostats is collectively called KSD, such as KSD301, KSD302, etc., the thermostat is a new type of bimetal thermostat, mainly as a variety of electric heating products with overheat protection, generally connected with the thermal fuse in series, sudden temperature ...

Analysis of common fault causes of RKC temperature controller Analysis of common fault causes of RKC temperature controller

1. The power indication is normal, but the temperature controller has no screen display. Most of this fault is caused by the heating of the voltage regulator element (7805 or 7812) on the thermostat during long-term use, which causes the solder joint to show a breakpoint, and sometimes it is caused by the phenomenon of virtual soldering at the factory. 2. Temperature controller ...

The debugging method of the temperature controller The debugging method of the temperature controller

Generally, there are three buttons to provide the need for setting, one is the Set button, press it once to enter the setting state. The other two offer upward and downward temperature adjustments, which can be adjusted to any temperature point. After adjusting to the desired temperature point, press the Set button again to confirm. 1. Turn on the smart thermostat ...

RLC thermostat – what you should pay attention to when maintaining your temperature controller RLC thermostat – what you should pay attention to when maintaining your temperature controller

1. Do not wipe with acidic, alkaline and other corrosive liquids and water-containing rags when cleaning, so as not to damage the temperature controller and affect its normal use. 2. Do not decorate and cover the temperature controller. The thermostat has a built-in temperature sensor to sense the outside temperature. Therefore, Wen ...

RLC thermostat – the wiring method of the thermostat RLC thermostat – the wiring method of the thermostat

Many household appliances and large-scale equipment products will be installed in the use of thermostats, thermostats will be combined with the change of ambient temperature in the switch when working physical deformation, which will produce some special effects, resulting in conduction or disconnection action, in order to achieve automatic ...

What should I pay attention to when wiring the RKG thermostat? What should I pay attention to when wiring the RKG thermostat?

1. For thermocouple input, the corresponding compensation wire should be used. 2. For RTD input, 3 wires with low resistance and no difference should be used 3. The input signal line should be far away from the power line of the instrument. Power supply and load lines to avoid noise interference 4. The instrument power cord is usually ...

RRKC Thermostat – Questions and Precautions About Thermostat Expansion Modules RRKC Thermostat – Questions and Precautions About Thermostat Expansion Modules

1. Under what circumstances should I use a thermostat to expand the module? The gradual development of the heating field is now very well recognized, and more and more users have begun to install electric heating, of course, when installing electric heating for users, they have also encountered some headaches. For example, a large area ...

RKC Level Gauge – Installation of a pontoon level gauge RKC Level Gauge – Installation of a pontoon level gauge

When transporting and unpacking, it is necessary to avoid excessive shock and vibration; The installation should be firm and reliable, and the pontoon should be installed vertically to prevent the pontoon from colliding with the interior wall of the pontoon; When the pontoon is hooked, it should not swing or pull and compress sharply, so as not to damage the sensor and reduce the accuracy of the instrument; ...

What are the characteristics of RLC thermostats – mechanical thermostats? What are the characteristics of RLC thermostats – mechanical thermostats?

1. Used to control fan coil unit, electric valve, damper and other equipment; 2. The switch adopts toggle type, which feels comfortable and has a long life; 3. Set the temperature by twisting (the temperature range can be limited); 4. The thermostat can be installed directly on the wall or on the standard junction box; ...

RK Thermostat - The working principle and device precautions of liquid expansion thermostat RK Thermostat - The working principle and device precautions of liquid expansion thermostat

How liquid expansion thermostats work Liquid expansion thermostat is a physical phenomenon (volume change) that causes the material (generally liquid) in the temperature sensing part of the thermostat to undergo corresponding thermal expansion and cold contraction when the temperature of the controlled object changes, and the diaphragm box connected with the temperature sensing part expands or ...

RKC Thermostats – How to Choose a Thermocouple? RKC Thermostats – How to Choose a Thermocouple?

The selection of thermocouples should be based on comprehensive considerations such as the operating temperature range, the required accuracy, the operating atmosphere, the performance of the measured object, the response time and the economic benefits. 1. Selection of measurement accuracy and temperature measurement range 1) The operating temperature is 1300-1800°C, and the accuracy is required to be more accurate than ...

RHK thermostat – a rapid detection method for common air conditioner thermostats RHK thermostat – a rapid detection method for common air conditioner thermostats

1. Bellows or diaphragm air conditioner thermostat 1. Fault phenomenon: poor contact or burning, resulting in the circuit can not be connected; The frequent action of the contact arc and sticking causes the circuit to be unbreakable; The thermostat in the temperature sensing chamber leaks, causing the contact to fail to operate and lose control. ...

RRKC thermostat wiring installation and some precautions RRKC thermostat wiring installation and some precautions

The rkc controller was developed by Japan and is mainly used in plastics and stoves. Of course, it is also widely used in China's industry, there are many people who do not know much about the rkc controller, and some even feel unfamiliar.

RK Thermostat - 5 Common Faults of Thermostat and Solutions RK Thermostat - 5 Common Faults of Thermostat and Solutions

1. After heating for a period of time, it is found that the temperature has not changed, and the temperature has been displayed at the time of the ambient temperature. In this case, you need to check that the SV value setting value is set, whether the OUT value indicator of the meter is not lit, and whether the No. 3 and 4 segments of the universal meter are 12VD ...

Wiring method of the RKG thermostat Wiring method of the RKG thermostat

Take CD901 as an example, L(1) pin to 220 volt live wire, N(2) pin 220 volt neutral wire, 3,4 pins for the first output, 5,6 pins for the second output, 7, 8, 9 pins are alarm output, Finally, the three pins are connected to thermocouples or PT100 ...

RKC converter - an introduction to the classification of converters RKC converter - an introduction to the classification of converters

  Analog-to-digital converters The analog-to-digital converter comprises a first transmission circuit, which receives an input voltage and an output clock signal, which is phase-shifted, depending on the input voltage, and a second transmission circuit receives a reference voltage and an input clock signal, and outputs a reference clock signal, which ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top