1. Engineering planning one by oneWith data at their fingertips and intelligent and sensitive functions, engineers can easily plan and test equipment, improve process availability, and easily complete system integration together – ultimately reducing the planning time by up to 25%. ...

How to choose a Schneider circuit breaker? How to choose a Schneider circuit breaker?

First, calculate the value of the current of each branch (1) Purely resistive loads, such as bulbs, electric heaters, etc., are directly divided by the indicated power by voltage, that is, the formula I = power/220v; For example, a 20w bulb, branch current I=20W/220=0.09A electric air ...

Analysis of the causes of Schneider touch screen touch deviation Analysis of the causes of Schneider touch screen touch deviation

(1) Fault--: Contact error Phenomenon 1: The direction of the finger does not coincide with the mouse arrow. Reason 1: After installing the driver, there is no vertical contact with the bullseye center when correcting the bearing. Solution 1: Re-align the bearing. Phenomenon 2: Some districts ...

Introduction to Schneider inverter fault code and maintenance method Introduction to Schneider inverter fault code and maintenance method

1. If the fault code presented on the Schneider inverter is AnF, it means that the load of the inverter has slipped, that is, the speed of the encoder does not match the initial value. First of all, we need to check whether the parameters of the motor are stable and the size of the load, ...

Schneider appeared at the 5th China Power Distribution Technology Summit Forum Schneider appeared at the 5th China Power Distribution Technology Summit Forum

Beijing, China, September 14, 2020 – Today, the 5th China Power Distribution Technology Summit Forum 2021, held by China Electric Power Research Institute Co., Ltd. and the Science and Technology Development Service Center of China Electric Power Council, opened in Beijing. The theme of this forum is "Supporting the Strategic Policy of Carbon Peaking and Carbon Neutrality, Building a ...

Troubleshooting methods in electrical circuit control - Schneider Troubleshooting methods in electrical circuit control - Schneider

The troubleshooting method of the electrical control line is not the same as a thousand people, and various methods can be used cooperatively, but do not copy the rigid set. In general, investigative research can help us to find out the problem. The experimental method can not only find out the fault phenomenon, but also find the fault location or fault circuit; Logic...

Circuit breaker mechanical characteristics tester operation steps - Schneider circuit breaker Circuit breaker mechanical characteristics tester operation steps - Schneider circuit breaker

Circuit breaker action time test. The closing and opening control lines of the circuit breaker mechanical characteristics tester are respectively connected to the secondary control line of the circuit breaker, and the lead wires of each break of the circuit breaker are connected to the mechanical characteristics of the circuit breaker with the test wiring.

Analysis of the causes of frequent overcurrent alarms of inverters - Schneider Analysis of the causes of frequent overcurrent alarms of inverters - Schneider

(1) Caused by incorrect parameter setting. If the acceleration time of the inverter is set too short, the change of the output frequency of the inverter far exceeds the change of the motor frequency, and when the inverter is started, it will trip due to overcurrent. Adjusting the acceleration time accordingly to different load conditions can eliminate this problem.

Fault check steps for frequency converters - Schneider frequency converters Fault check steps for frequency converters - Schneider frequency converters

1. Check whether the appearance of the inverter is in good condition, including whether the indicator light is running normally, whether the task control function of the operation panel is complete, and carefully observe the appearance of the inverter in the operating state, and do the corresponding recording work; When repairing the inverter, check whether the voltage value and current value exceed the allowable ...

Schneider inverter ATV32 book type performance and advantages Schneider inverter ATV32 book type performance and advantages

Schneider ATV32 book inverter has built-in programmable controller function, flexible and intelligent; Integrated safety functions, 30% cost savings compared with external security modules; First-class Schneider patented synchronous motor open-loop control technology; Book-type design, support side-by-side installation, space-saving; Many...

Precautions for setting parameters of Schneider inverter Precautions for setting parameters of Schneider inverter

 Debugging parameters: ​ 1. Acceleration and deceleration time Speed up the time setting requirements: the acceleration current is constrained below the overcurrent capacity of the inverter, so that the overflow will not cause the inverter to trip; Deceleration time setting key ...

The difference between circuit breaker and air opening - Schneider The difference between circuit breaker and air opening - Schneider

An air switch, also known as an air circuit breaker, is a type of circuit breaker. It is a switch that only needs the current in the circuit to exceed the rated current will be actively disconnected, and is generally used to avoid circuit overload and short-circuit maintenance (some also have low voltage maintenance functions) can not maintain electric shock, to put it bluntly, it is ...

How can industry be high-quality and sustainable? - Schneider How can industry be high-quality and sustainable? - Schneider

Sanya, China, October 21, 2021 – In the context of the ever-changing global development situation and the increasingly urgent response to carbon neutrality, Ruan is moving towards carbon neutrality together with cost reduction and efficiency increase, which has become the focus of attention of many industrial enterprises. As a global digital transformation specialist in power management and automation...

Schneider Thermal Relay Model Meaning Schneider Thermal Relay Model Meaning

The function of the thermal relay is mainly used to carry out overload maintenance on the asynchronous motor, and his operating principle is that after the overload current passes through the thermal element, the bimetal sheet is heated and twisted to advance the action organization to drive the contact action, so as to disconnect the motor control circuit to realize the motor power-off thermal relay ...

Schneider Lexium ILA all-in-one AC servo Schneider Lexium ILA all-in-one AC servo

The Schneider Lexium integrated drive consists of an electric motor and a control circuit that announces the control signal via a fieldbus, pulse/direction interface or I/O interface (for internal motion tasks). High compactness: motor and control circuits ...

Schneider intermediate relays Schneider intermediate relays

  Schneider 24VDC intermediate relays are the most common components in control systems. Generally, 2 normally open and 2 normally closed are the most commonly used, but sometimes 4 normally open and 4 normally closed contacts are not enough. Both have different coil and base models. ...

Schneider's new Modicon programmable controller PLC series Schneider's new Modicon programmable controller PLC series

Schneider Electric, the global energy efficiency management specialist, has launched the new Modicon Programmable Manipulator (PLC) M221 series, M241 series and M251 series under the MachineStruxure machine automation channel. This series of new products is tailored for industrial OEM shopping malls, relying on Schneider Electric global ...

The difference between high voltage and low voltage of Schneider inverter The difference between high voltage and low voltage of Schneider inverter

1. What is the difference between high-voltage inverter and low-voltage inverter? Frequency converters can be broadly divided into two categories: high-voltage frequency converters and low-voltage frequency converters. In terms of use, the applicable objects are different, and the high-voltage motor is the same from the principle of speed regulation. From the topology ...

How to prevent counterfeiting from Schneider switch sockets How to prevent counterfeiting from Schneider switch sockets

1. Logo The logo of the product is a status symbol, so it will be made very exquisitely. Schneider switches are also very careful in the production of logo, each letter is like an independent work of art, and let's see that the letter "A" is flat and wide. But the imitation ...

Schneider DC air open up plus or minus? How to connect the incoming and outgoing lines? Schneider DC air open up plus or minus? How to connect the incoming and outgoing lines?

The air switch is divided into the upper inlet line and the lower inlet line of the power supply, 1 is - 3 is + 2 is + 4 is - when the upper line is inlet, 2 is + 4 is - This is related to the internal trip curve. DC circuit breaker is used for DC system operation method conversion or fault removal ...

Schneider Modicon M100 Programmable Controller Features and Benefits Schneider Modicon M100 Programmable Controller Features and Benefits

The Schneider Electric Modicon M100 programmable controller is part of the Easy Series and is suitable for simple I/O logic control machines. characteristic AC power supply High-speed processor with 0.2μs/boolean amount Built-in a ...

Next Page »
12345678910Next
CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top