Schneider's new Modicon programmable controller PLC series

Create Date: 2024-8-30 12:03:23|Source: Schneider/Schneider

Schneider Electric, the global energy efficiency management specialist, has launched the new Modicon Programmable Manipulator (PLC) M221 series, M241 series and M251 series under the MachineStruxure machine automation channel. This series of new products is tailored for industrial OEM shopping malls, relying on Schneider Electric's global R&D resources, and leading the future development of OEM small and medium-sized shopping malls with innovative concepts. The design of this series of products leads the industry in a number of functions, which can effectively assist industrial OEM customers to maximize the function and performance of their machines, and enhance the core competitiveness of OEMs in the era of the third industrial revolution.

                                 Schneider's new Modicon programmable controller PLC series

Smart and compact, not "think" – the PLCs of the M221 series

This series of programmable manipulators is divided into two types: book type and integrated body. According to the SoMachine Basic software channel, it is designed for simple machines and equipment, with a compact form factor and optimized installation space. The body has built-in high-speed counting, pulse output and analog input methods, and supports Ethernet and Modbus communication. With high cost performance and simple operation methods, it has become an ideal choice for repetitive process equipment such as packaging machinery and textile machinery.

Highly integrated, "tolerant" is large – M241 series PLC

The M241 series programmable manipulators, based on the SoMachine V4 software channel, are suitable for high-performance machine control with motion control functions. The high-speed dual-core CPU processor is powerful, and all CPUs support PTO functions, which helps to complete the correct positioning control; The body has built-in high-speed counting and pulse output. It supports Ethernet, CANOpen, serial communication, and users can also choose TM4 communication expansion module for high communication integration. In addition, the M241 series uses TM3 expansion, which is 10 times faster than TM2 and supports SD cards and TMC4 expansion boards.

Scatter control, communication superman – M251 series PLC

This series of programmable manipulators is a product that provides a modular and distributed architecture, and provides customers with innovative and high-performance solutions based on the SoMachine V4 software channel. It uses a book-type body, which can support TM3 and TM4 expansion modules, and is equipped with very sensitive. The CPU core has excellent processing power, built-in super communication ability, supports CANOpen and up to 2 Ethernet, is open and sensitive, and can easily complete the distributed architecture, especially suitable for scattered control with long distances.

In addition to the superior hardware, Schneider Electric has developed a matching high-performance software that is perfectly combined with it. As the general development software of MachineStruxure machine automation channel upgrade, Schneider Electric has recently launched the easy-to-use SoMachine Basic and comprehensive SoMachine V4 programming software according to the objective needs and usage habits of Chinese customers, so that OEM customers can optimize the automatic control solution plan according to the actual use needs, enhance the applicability of the plan, and complete higher added value in the whole life cycle of the machine.
More on that
Inverter selection principle - Schneider Inverter selection principle - Schneider

1. Select the inverter according to the load characteristics. 2. When selecting the inverter, the actual motor current value should be used as the basis for the selection of the inverter, and the additional power of the motor can only be used as a reference. Secondly, the output content of the inverter should be fully considered.

"Five Ways" to Solve Life Sciences Industry Challenges – Schneider "Five Ways" to Solve Life Sciences Industry Challenges – Schneider

In life sciences careers, equipment performance is critical to ensuring business continuity and useful production time. The main challenges faced by the industry include: maintaining the positive impact of environmental parameters on product quality, managing multiple systems in a "siloed" state, and using existing infrastructure sensitively and efficiently.

Precautions for trial operation of Schneider motors Precautions for trial operation of Schneider motors

1. Check during the test run of the motor 1.1 Before the motor starts It is necessary to carefully check whether the insulation resistance is qualified, check whether the wiring of the secondary circuit is correct, and the inside of the motor should be boring, clean and free of debris. Investigate whether the fastening bolts of the motor are loose and the bearing is ...

Introduction to the transformer connection group - Schneider Introduction to the transformer connection group - Schneider

In the transformer planning process, the choice of wiring method is often not paid attention to. The three-phase transformer has A/B/C three-phase winding on the 1/2 side. The connection between them has a great impact on the operation performance of transformers, especially distribution transformers, and directly affects the quality of power supply. Therefore, the wiring ...

How Schneider contactors work How Schneider contactors work

1. Contactor refers to an electrical appliance that uses a coil to flow through an electric current to generate a magnetic field, so that the contact is closed, and then the load can be controlled. Because it can quickly block the main circuit and frequently connect the equipment with high-current control circuits, it has been widely used in electrical engineering.

The difference between circuit breaker and air opening - Schneider The difference between circuit breaker and air opening - Schneider

An air switch, also known as an air circuit breaker, is a type of circuit breaker. It is a switch that only needs the current in the circuit to exceed the rated current will be actively disconnected, and is generally used to avoid circuit overload and short-circuit maintenance (some also have low voltage maintenance functions) can not maintain electric shock, to put it bluntly, it is ...

Schneider UPS power supply installation steps Schneider UPS power supply installation steps

UPS power supply is widely used in shopping malls, supermarkets, banks and other enterprises and institutions, the primary effect of the power supply is to provide continuous power supply for the unit in the state of power failure, so as to ensure the normal operation of the computer network system and other application systems, and effectively avoid data loss. In the power supply ...

Troubleshooting methods in electrical circuit control - Schneider Troubleshooting methods in electrical circuit control - Schneider

The troubleshooting method of the electrical control line is not the same as a thousand people, and various methods can be used cooperatively, but do not copy the rigid set. In general, investigative research can help us to find out the problem. The experimental method can not only find out the fault phenomenon, but also find the fault location or fault circuit; Logic...

Schneider considers the safety of lithium batteries from four perspectives Schneider considers the safety of lithium batteries from four perspectives

In China, the trend of UPS switching to lithium batteries will become more and more rapid. As a global leader in data center infrastructure solutions and services, Schneider Electric found that in addition to the purchase price factor, Chinese customers are now choosing the weight of UPS lithium batteries after accurate positioning and inquiry of shopping malls.

Schneider ATV630 VFD series advantages Schneider ATV630 VFD series advantages

Depending on the customer's requirements, wall-mounted drives, built-in cabinets and floor-mounted free-standing solutions in protection classes IP 21, IP 23, IP 54 and IP 55 are available. Thanks to the built-in pump monitoring function, the device reacts immediately when pump efficiency drops, resulting in ...

Schneider instrumentation fault diagnosis method Schneider instrumentation fault diagnosis method

1. Percussion hand pressure method When we use the instrument, we often encounter the phenomenon that the instrument is running well and badly, and most of this phenomenon is caused by poor contact or virtual welding. In this case, percussion and hand pressure can be used. The so-called "percussion" is the response to the ...

Instrumentation overhaul points - Schneider Instrumentation overhaul points - Schneider

The test input does not conform to the "short" rule, and the problem is here. 1. Overhaul according to the comparator rules, fit it, the piece is good, and check the periphery; It doesn't fit, the piece is bad. 2. It does not fit the "virtual break" - there are ...

Schneider instrumentation maintenance precautions Schneider instrumentation maintenance precautions

1. Don't blindly knock and bump when overhauling to avoid expansion failures, and the more you repair, the worse it gets. 2. Do not plug and unplug various control boards and plugs with electricity. Due to the strong induced electromotive force generated by plugging and unplugging the control board under the power-on condition, the instantaneous ...

Precautions for external wiring of the inverter Precautions for external wiring of the inverter

In the process of connecting the line of the inverter, it is necessary to pay attention to the following aspects: 1. The power supply must be connected to the main circuit power terminal L1/R, L2/S, L3/T, if the power supply is connected to other terminals by mistake, the inverter will be damaged. 2. It is necessary for the grounding terminal to be well connected.

Schneider inverter motor control mode Schneider inverter motor control mode

Fundamentals of magnetic flux vector manipulation The control of a three-phase asynchronous motor is much more messy than that of a DC motor because the current, voltage, induced potential, magnetic flux, etc., of the stator and rotor are all alternating. However, the stator winding of the three-phase asynchronous motor is a symmetrical three-phase winding, which exerts a ...

The difference between Schneider verification, calibration, and calibration The difference between Schneider verification, calibration, and calibration

What is the difference and contact between the instrument, external work verification, calibration, and calibration? Verification, calibration, and calibration are all static measurement processes that are carried out in cycles. The meanings are: The verification ---- shall be arranged by the legal metrology department or the statutory authorization in accordance with the verification procedures, after ...

The control mode of low-voltage inverter - Schneider The control mode of low-voltage inverter - Schneider

From the perspective of skills alone, the control method of the low-voltage inverter also indicates its skill portal to a certain extent. Here, we've broken down the following manipulation methods: 1. Sinusoidal pulse width modulation Sinusoidal Pulse Width Modulation (SPWM) is characterized by the simple structure of the control circuit, the cost of ...

Schneider selection of different types of circuit breakers Schneider selection of different types of circuit breakers

Schneider miniature circuit breakers are: A9 (iC65, iDPN, etc.), M9 (C65, DPN, C120, NG125, etc.), E9, OSMC32N/OSMC65H, etc Schneider molded case circuit breakers are: NSX, NSE, EZD, NSC, large plastic case NS Schneider structural circuit breakers have ...

Power wiring requirements for Schneider PLC Power wiring requirements for Schneider PLC

The power supply of the DPLC should be taken from the trunk line with a relatively stable voltage or the special line led by the bus of the substation to ensure the voltage quality of the PLC. If the voltage fluctuates too much, consider installing a voltage regulator or uninterruptible power supply (UPS). 2. The power cord is best to use twisted pair, and its cross-sectional area should not be less than 2 square millimeters.

The energy-saving effect of using frequency converter for fan and pump loads The energy-saving effect of using frequency converter for fan and pump loads

Why is the use of inverter for fan and pump loads to save energy? According to the basic laws of fluid mechanics, it can be seen that the fan pump load is a typical square rotation load, and its main characteristics are: speed n and torque T and load ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top