1. Logo
The logo of the product is a status symbol, so it will be made very exquisitely. Schneider switches are also very careful in the production of logo, each letter is like an independent work of art, and let's see that the letter "A" is flat and wide. However, the imitation is not very well handled on the logo, the plane above the letter "A" is relatively narrow, and even the top is directly pointed. Everyone must pay attention to this point.
2. Details
In the process of switch processing, every detail is more important. Don't dare to be careless at this point, the production of the switch inside is also more elegant, everyone looks at the place where I draw the symbols, is it very neat, and the imitation, I don't know what it is, and the black flaws, many people are looking at it, focusing only on the appearance, in fact, the details inside are the key to discernment.
3. The main part
Let's take a look at the main part of it. The thickness of the main body is relatively thin, and there is a reflective effect on it. The main body of the fake Schneider switch is thicker, it may be the connection of the position, everyone does not see it very clearly, in fact, the distance can still be compared. And the main body of the fake is not very reflective, I don't know what raw materials are made of.
4. Packaging
In terms of packaging, the identification is actually relatively simple. The packing tape is more solid to the touch and has a better seal. In general, the packaging bags of imitation products are relatively thin, and the packaging is not very tight, and sometimes there is an opening. In addition, let's look at the product manual and the delivery screws. The paper of the instruction manual is better, and the screws look thicker and stronger. The manual printed on the imitation is relatively vague, and the screws are relatively thin, which looks a little thin.
5. Anti-counterfeiting
Next to the switch, each Schneider switch has an anti-counterfeiting label. If we use a colored pen to paint the area of "fluorescent ink", the "F" type will show the color of the pen; If we uncover the "partial nuclear microporous membrane", we will see the transparent "F" picture inside; If we use ultraviolet light to shine on the anti-counterfeiting label, it will show yellow handwriting; In addition, let's uncover the "aluminized implicit encryption" layer, which will be printed with yellow handwriting illuminated by ultraviolet light.
|
More on that
|
Schneider inverter ATV310 instruction with given
The instructions of the inverter are given with the given
conf→400-
→ 401 (given channel), → 01 (given analog terminal), 163 (given by remote display terminal), 164 (given by mudobus communication), 183 (navigation knob ...
|
|
Features of Schneider explosion-proof inverter boxes
1. Aluminum alloy shell or steel plate welding, plastic spraying on the surface;
2. Built-in inverters, circuit breakers, signal lights and other components produced by domestic or Schneider and other companies;
3. It mainly regulates the general three-phase difference by changing its output frequency.
|
|
Schneider intermediate relays
Schneider 24VDC intermediate relays are the most common components in control systems. Generally, 2 normally open and 2 normally closed are the most commonly used, but sometimes 4 normally open and 4 normally closed contacts are not enough. Both have different coil and base models.
...
|
|
Schneider relay model introduction
RM4 Series Control Relay (Three-phase Power Control)
RM4 series voltage steerable relays
RM4 current operated relay
RM4 level control relay
RM17 three-phase power controller
RM35 3-phase power control relay
RM17 Voltage Steerable Relay ...
|
|
"Five Ways" to Solve Life Sciences Industry Challenges – Schneider
In life sciences careers, equipment performance is critical to ensuring business continuity and useful production time. The main challenges faced by the industry include: maintaining the positive impact of environmental parameters on product quality, managing multiple systems in a "siloed" state, and using existing infrastructure sensitively and efficiently.
|
|
Inverter maintenance inspection steps – Schneider
1. Check whether the appearance of the inverter is in good condition, including whether the indicator light is in normal operation, whether the task control function of the operation panel is complete, and carefully observe the appearance of the inverter in operation conditions, and do the corresponding recording operations; When repairing the inverter, check whether the voltage value and current value exceed the allowable ...
|
|
Schneider Electric executive support merger software Saas company
MergerWare has raised an undisclosed amount of money ahead of its Series A funding round, an executive told TechCircle. The Company provides software solutions to help integrate mergers and acquisitions-related businesses. The funding came from electrical equipment manufacturer Schneider Electric (Schneider ...
|
|
Circuit breaker failure protection - Schneider
Circuit breaker failure maintenance refers to the relay maintenance action of faulty electrical equipment when the trip command is announced and the circuit breaker refuses, the maintenance action information of the faulty equipment and the current information of the rejected circuit breaker constitute the judgment of circuit breaker failure, and other related problems in the same plant and station are cut off in a shorter time limit.
|
|
Classification of Schneider molded case circuit breakers
1. According to the device method, it is divided into: vertical installation and horizontal installation.
2. According to the use of circuit breakers: power distribution maintenance type, motor maintenance type.
3. According to the wiring method: board front wiring, board back wiring, plug-in wiring.
...
|
|
Schneider inverter debugging steps and brief description
Commissioning process of the Schneider 61 series
1. Preparations
1. Measure insulation. Connect the power supply side (R.S.T) and the motor side (U.V.W) of the inverter
Disconnect the cable, insulate the cable with a 500 megaohm or 1000 megaohm shake meter, and if it meets the requirements, restore it.
|
|
The difference between Schneider and Siemens PLC
There are three main differences, namely: different uses, different products, and different characteristics.
1. Different use cases: The programmable manipulator produced by Siemens in Germany is also widely used in China, and has been used in metallurgy, chemical industry, printing production lines and other fields.
|
|
Introduction to Schneider limit switch series
1. XCKN compact limit switch
Light and medium load use;
Waist-shaped device holes for easy adjustment of mechanical errors;
Bipolar isolation definitely disconnects the contacts;
External waterproof sealing joint, the protection level is higher than that of rubber sleeve sealing pipe;
Engineering plastic body, avoid temperature ...
|
|
The inverter has a problem supplying power to the motor – Schneider
A frequency converter is a device that converts power to other frequencies of power supply. The power frequency of our country is 50Hz, in the field of motors, in order to change the speed of the motor, or other performance changes, many motors choose inverter power supply.
The inverter is a supporting operation with the inverter motor.
|
|
Two of Schneider's low-voltage power distribution products won the Germany Red Dot Award
Beijing, China, April 6, 2022 – Recently, the list of "Red Dot Planning Awards", known as one of the world's three cutting-edge industrial planning awards, was grandly announced in Germany.
|
|
Factors influencing the differential thermal analysis of instrumentation - Schneider
The operation of differential thermal analysis is simple, but in practical work, it is often found that the same sample is measured on different instruments, or different measurements are measured on the same instrument, and the results of the differential thermal curve of industrial electrical appliances are different. The high temperature, shape, area, and size of the peaks will all change. ...
|
|
Schneider disconnector operation inspection contents
(1) Whether the closing condition of the isolation switch is not defective, and whether there is any failure or dislocation;
(2) The porcelain insulation of the isolation switch should be free of defects, no cracks, no discharge phenomena and flashover traces;
(3) Contact inspection: a. Check the contact ...
|
|
Schneider turbine flowmeter selection considerations
1. According to the requirements of measurement intention:
It is required to select the unit with instantaneous flow rate or cumulative flow rate (cumulative flow), the unit of flow display, measurement accuracy, repeatability, linearity, flow scale and scale, measurement temperature, pressure loss, temperature and pressure compensation, output signal characteristics and echoes.
|
|
Inverter selection and capacity matching method - Schneider
How to carry out the selection of inverter normally, is the difficulty faced by many enterprise technical personnel and business personnel, in addition, the selection of the inverter body alone, without considering whether the inverter selection and capacity matching is appropriate, is also unscientific.
...
|
|
Schneider ATV312 inverter failure
1. OLF is motor overload.
Possible reasons: 1. Triggered by high motor current. 2. The value of the [cold stator resistance] (rSC) parameter is wrong.
Corrective measures: 1. Check the [Motor Thermal Current] (ItH) setting of the motor thermal maintenance function and check the motor load. Wait...
|
|
Schneider inverter maintenance inspection steps
1. Check whether the appearance of the inverter is in good condition, including whether the indicator light is in normal operation, whether the task control function of the operation panel is complete, and carefully observe the appearance of the inverter in operation, and do the corresponding recording operation; When repairing the inverter, check whether the voltage value and current value exceed the promised ...
|
|