Mitsubishi touch screen common faults and solutions Mitsubishi touch screen common faults and solutions

Fault 1: Mitsubishi touch screen contact deviation Phenomenon: The direction of finger contact does not match the mouse arrow. Analysis: When calibrating the orientation after installing the screwdriver, there is no vertical contact with the bull's-eye. Solution: Recalibrate the bearing. ...

Special function module of the Mitsubishi PLC FX series Special function module of the Mitsubishi PLC FX series

The communication module of PLC is used to complete the communication with other PLCs, other intelligent control equipment or computers. The following is a brief introduction to the FX series communication function shields, adapters and communication modules. (1) Communication expansion ...

Mitsubishi PLC command negation, empty operation and END, etc Mitsubishi PLC command negation, empty operation and END, etc

Introduction to Mitsubishi PLC directives such as negation, air operation and END The INV (Inverse) command is represented by a short 45° slash at the top of the ladder diagram, which negates the result of the operation before the execution of the instruction, and the result of the operation is 0 ...

Mitsubishi PLC advantages Mitsubishi PLC advantages

Discrete control and motion control, Mitsubishi's instructions are abundant, there are dedicated positioning instructions, control servo and stepping are easy to complete, to complete some messy action control is also Mitsubishi's strength, and Siemens is weaker in this area, there is no special instruction, do servo or step positioning control is not ...

Anti-interference performance measures of Mitsubishi PLC system Anti-interference performance measures of Mitsubishi PLC system

1. Choose a power supply with excellent performance and press the disturbance introduced by the power grid In the PLC control system, the power supply occupies a very important position. The power grid disturbance series into the PLC control system is mainly through the power supply of the PLC system (such as CPU power supply, I/O power supply, etc.), the power supply of the transmitter and the power supply with P ...

Mitsubishi participated in the 4th CIIE to introduce the E-JIT green induction solution Mitsubishi participated in the 4th CIIE to introduce the E-JIT green induction solution

On November 5, 2021, the 4th China International Import Expo was grandly held at the National Convention and Exhibition Center in Shanghai. At the 4th CIIE, Mitsubishi Electric's booth was located in Hall 4.1 of the Technical Equipment Zone of the Convention and Exhibition Center, with an exhibition space of 400 square meters. At Mitsubishi Electric's booth, the high-profile event was ...

Mitsubishi inverter FR-E024-0.75K repair Mitsubishi inverter FR-E024-0.75K repair

Type: FR-E024-0.75K Fault: The boot cannot be started Maintenance: This machine does not provide any symptom information, and the display screen shows an "E.THT" error when the motor is to be started after powering on. Check the instructions refer to the ...

Mitsubishi PLC FX series position control unit Mitsubishi PLC FX series position control unit

The FX-20GM is a 2-axis positioning machine that can be operated independently. 1. Pulse output unit 1. Point-controlled pulse output unit F2-30GM 2. Pulse output module FX-1PG (for FX2 and FX2C) ...

Mitsubishi PLC main maintenance and overhaul content points Mitsubishi PLC main maintenance and overhaul content points

The main content of the protection and maintenance of Mitsubishi PLC Although the failure rate of PLC is very low, the control system composed of PLC can operate stably and reliably for a long time, and it is essential to protect and view it alone. Generally, every six months ...

Mitsubishi PLC FX series programmers and other peripherals Mitsubishi PLC FX series programmers and other peripherals

1. FX series programmer The programmer is an important peripheral device of the PLC, which is used to write the user program to the PLC user program memory. On the one hand, it can be programmed by the PLC, and on the other hand, it can monitor the working status of the PLC. With the development of PLC skills, the multi-...

Mitsubishi Step Ladder Instruction [STL], [RET] usage example Mitsubishi Step Ladder Instruction [STL], [RET] usage example

Step Instruction (STL) is an instruction that uses internal software components to control the process step on top of the sequential control program. A step-to-back instruction (RET) is an instruction that is used to return to the main program (bus) after the state (S) process is completed. ...

Mitsubishi Electric develops satellites for greenhouse gas and water cycle observations Mitsubishi Electric develops satellites for greenhouse gas and water cycle observations

TOKYO, March 30, 2020 – Mitsubishi Electric Corporation (Tokyo: 6503) announced today that it has been appointed by the Japan Aerospace Agency (JAXA) as the contractor for the Global Satellite Observing Satellite for the Greenhouse Gas and Water Cycle (GOSAT-GW), the third satellite in the GOSAT series, ...

Mitsubishi Electric Europe Ltd. acquires AQS, a Sweden air conditioning distributor Mitsubishi Electric Europe Ltd. acquires AQS, a Sweden air conditioning distributor

TOKYO, April 2, 2020 - Mitsubishi Electric Corporation (TSE: 6503) announced today that its European subsidiary, Mitsubishi Electric Europe Ltd., acquired all the shares of AQS PRODUKTER AB, a Sweden company in the comfort, craft industry, on April 1.

Mitsubishi Electric develops production line improvement technology Mitsubishi Electric develops production line improvement technology

TOKYO, March 26, 2020 – Mitsubishi Electric Corporation (TSE: 6503) announced today that it has developed a new technology for efficient design and material flow of production floor layouts and accurate estimates ® of productivity using Mitsubishi Electric's Maisart *AI.

Mitsubishi Electric develops technology for high-power-density converters with embedded components Mitsubishi Electric develops technology for high-power-density converters with embedded components

TOKYO, March 25, 2020 – Mitsubishi Electric Corporation (TSE: 6503) today announced that it has developed a new technology that integrates power devices, passives, sensors, and other embedded components on the same substrate and performs the dispensing at 100kW (continuous) power.

Mitsubishi Electric develops MEMS LiDAR solutions for autonomous vehicles Mitsubishi Electric develops MEMS LiDAR solutions for autonomous vehicles

TOKYO, March 12, 2020 - Mitsubishi Electric Corporation (TSE: 6503) today announced that it has developed a compact Light Detection and Ranging (LiDAR) solution that integrates microelectromechanical systems (MEMS) that enable ultra-wide horizontal scanning angles in the self-...

Mitsubishi Electric begins research and development of a Mars satellite probe probe Mitsubishi Electric begins research and development of a Mars satellite probe probe

TOKYO, February 21, 2020 – Mitsubishi Electric Corporation (TOKYO:6503) announced today that it has been appointed by the Japan Aeronautics and Astronautics Agency (JAXA) as the contractor for the Mars Lunar Probe (MMX) space probe. Mitsubishi Electric has launched development activities for the project that will utilize MMX's system ...

Introduction to Mitsubishi tension controllers Introduction to Mitsubishi tension controllers

1. Tension Manipulator Principle - Introduction The tension manipulator can be called the tension manipulator, which is usually used with magnetic particle brake, magnetic particle clutch and tension detector, which is suitable for winding, unwinding, tension control, etc. It also has the so-called manual control function, which generally refers to the fact that human beings can ...

Mitsubishi servo maintenance failure analysis Mitsubishi servo maintenance failure analysis

Major Failures and Analysis: 1. Motor encoder alarm 1. The cause of the failure (1) Wrong wiring; (2) electromagnetic interference; (3) Encoder hardware damage caused by mechanical vibration; (4) Pollution caused by the on-site environment; 2. Troubleshooting ...

Introduction to Mitsubishi PLCFX3U positioning control Introduction to Mitsubishi PLCFX3U positioning control

1. The workbench runs in the direction of the decrease of the value of the current value register (generally M8342=OFF in the opposite direction), and when it encounters the near-point signal, it becomes a creeping speed, and the zero-point signal after leaving the near-point signal arrives with a delay of 1ms, and the pulse output is immediately aborted. ...

PLC Programming Recommendations – Mitsubishi PLC PLC Programming Recommendations – Mitsubishi PLC

1. When the PLC and the host computer (or touch screen) form a monitoring system, there are many hours on the screen that require "manual", "active" and other control forms (generally more than one). In the program, you can use the "MOV" command. For example, when selecting "manual", the constant 1 MOV will be changed to a ...

Next Page »
12345678910Next
CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top