Mitsubishi touch screen common faults and solutions

Create Date: 2024-8-30 12:03:23|Source: Mitsubishi Electric/Mitsubishi Electric

Fault 1: Mitsubishi touch screen contact deviation

Phenomenon: The direction of finger contact does not match the mouse arrow.

Analysis: When calibrating the orientation after installing the screwdriver, there is no vertical contact with the bull's-eye. Solution: Recalibrate the bearing.

                              Mitsubishi touch screen common faults and solutions

Fault 2: Mitsubishi touch screen contact deviation

Phenomenon: Some area contacts are accurate, some area contacts are biased.

Analysis: The sound wave reflection fringes around the sonic touch screen 4 on the exterior accumulate a lot of dust or scale, which affects the transmission of the sound wave signal.

Solution: Clean the touch screen, especially the 4-sided sound reflection stripes of the touch screen, and it is necessary to disconnect the power supply of the touch screen controller card when cleaning.

Fault 3: Mitsubishi touch screen does not respond contactlessly

Phenomenon: The mouse arrow does not do anything when touching the screen, nor does it change orientation.

Analysis: This can happen for a variety of reasons, including:

(1) The dust or dirt accumulated on the sound wave reflection stripes around the sonic touch screen 4 is very serious, and the touch screen cannot operate normally;

(2) Touch screen failure;

(3) Control card failure;

(4) Signal line failure;

(5) Serial port failure on the computer host;

(6) Failure of the computer's operating system;

(7) The driver device is at fault.
More on that
Mitsubishi PLC's communication inspection method Mitsubishi PLC's communication inspection method

When you are ready to communicate through AJ71QE71, perform a ping in MS-DOS format to check if the connection is correct before the Mitsubishi PLC's GPPW starts to communicate. The support communicates with the Weilun touch screen through the serial port. ...

How to create a Mitsubishi CPU module project How to create a Mitsubishi CPU module project

Mitsubishi CPU module engineering creation method Start engineering tools, create projects. [Establishment process] 1. Select the CPU module to be used in the "Model" item. In the "Programming Language" project, select ...

PLC commonly used physical memory - Mitsubishi PLC commonly used physical memory - Mitsubishi

(1) Random Access Memory (RAM) The user can read out the content of the RAM with the programming device, and can also write the user program to the RAM, so the RAM is also called read/write memory. It is volatile memory, and when its power is interrupted, the stored information is lost. The use of the computer's memory module ...

Mitsubishi FX5U series PLC advantages Mitsubishi FX5U series PLC advantages

1. CPU function As a MELSEC IO-F series PLC actuator, it is equipped with executable structured programs and multiple program actuators, and can be written to ST language and FB. 2. Built-in analog input and output (alarm output by the way) Built-in 12-bit 2-channel analog input ...

Mitsubishi inverter basic questions and answers Mitsubishi inverter basic questions and answers

1. Question: What is the type of RS485 to RS232C converter used by Mitsubishi inverter for communication? Solution: FA-T-RS40* Mitsubishi inverter is available. 2. Question: Mitsubishi inverter frequency external potentiometer is given, and the external potential recommended to be used ...

Fault analysis of Mitsubishi inverter OC1 and OC3 Fault analysis of Mitsubishi inverter OC1 and OC3

Mitsubishi inverter OC (overcurrent problem) will be caused by the following reasons, taking A500 series inverter as an example: 1). Caused by improper parameter setting problems, such as time setting is too short. 2). ...

Mitsubishi PLC password protection settings Mitsubishi PLC password protection settings

In GX Works3, there are three types of security settings: block password, security key, and file password. The block password is for the program to prevent others from reading and writing changes, only for the program; The file password is for the PLC to prevent others from reading and writing changes. Security keys are both capable of ...

Mitsubishi FX2N Series Extended PLC Module Selection Chart Mitsubishi FX2N Series Extended PLC Module Selection Chart

The Mitsubishi iQ-F series is compatible with CC-Link IE TSN motion modules The Mitsubishi iQ-F series is compatible with CC-Link IE TSN motion modules

The new iQ-F motion module is a controller that can perform advanced motion control such as positioning, synchronization, cam, speed, torque, etc., with a computing cycle of 500μs, and can be connected to a high-function servo amplifier through CC-Link IE TSN, making a higher contribution to the miniaturization and high functionality of the equipment. ...

What are the main factors of interference in Mitsubishi PLC system? What are the main factors of interference in Mitsubishi PLC system?

(1) Radiative dry disturbance from space The radiated electromagnetic field (EMI) in space is mainly caused by power networks, transient processes of electrical equipment, lightning, radio broadcasting, television, radar, frequency induction heating equipment, etc., generally known as radiation disturbance, and its dispersion is extremely chaotic. ...

The inverter completes the multi-speed function - Mitsubishi The inverter completes the multi-speed function - Mitsubishi

The inverter can be preset with a number of different speed points, and then complete the scheduling of multiple speed stages. The specific completion method is as follows: You can set a number of different speed points in the VFD, and you can generally set the maximum speed, minimum speed, and several center speed points. According to the needs, choose ...

Mitsubishi PLC hardware installation method Mitsubishi PLC hardware installation method

1. Use the special crimping pliers for network cable to crimp one end of the cable and the RJ45 crystal head; The other end is connected to the FX2N-485-BD communication template according to the method shown in Figure 1-Figure 3, and the two unused P5S terminals are not connected. 2. Open the panel cover on the left side of the PLC host, and put the FX2N-485-BD communication module ...

Mitsubishi PLC adjusts the built-in time Mitsubishi PLC adjusts the built-in time

1. TWR (Time Write) command Write the time preset value to the built-in real-time clock: Clock information is written to the TWR (Time Write) command. The sequence number of the action instruction is FNC167, [S ·] T, C and D can be used, and only 16-bit operations can be used, accounting for 5 program steps. The work of the directive ...

Mitsubishi PLC control servo motor method Mitsubishi PLC control servo motor method

1. The transistor output type of the FX series generally sends pulses to the servo through the output point of Y0, Y1 or the positioning module, and the speed and direction of the servo depend on the frequency and direction of the pulse in your program. Mitsubishi FX3U series ...

Features of the MELSEC iQ-R series of programmable controllers Features of the MELSEC iQ-R series of programmable controllers

1. Routine control is consistent with safety control In the MELSEC-QS series, it is necessary to prepare a system for conventional control and a system for safety control. With the MELSEC iQ-R series of safe programmable controllers, it is possible to combine conventional and safe control into a single system. Quiet...

The impact of Mitsubishi inverters on the quality of the power grid The impact of Mitsubishi inverters on the quality of the power grid

In the case of impact loads such as electric welding machines, electric arc furnaces, rolling mills, etc., the voltage often flickers; In a workshop, when there are multiple Mitsubishi inverters and other capacitive rectifier loads working, the harmonics that occur are very serious pollution about the quality of the power grid, and there is also considerable damage to the equipment itself.

PLC Processor Performance Test – Mitsubishi PLC Processor Performance Test – Mitsubishi

The processor performance test should be carried out in accordance with the requirements of the system manual, to ensure that the system has the function described in the manual, and is stable and reliable, including the system communication, backup battery and other special modules to view. Redundancy testing is necessary for systems with redundant equipment. i.e. the redundant design ...

Query Error Code Method – Mitsubishi Query Error Code Method – Mitsubishi

Error Number (D8063): 6314 ERROR MESSAGE: PARALLELLINKERROR (PARALLEL OPERATION COMMUNICATION ABNORMAL) Error content: Parallel operation string abnormal Method: Whether the power supply of the two PLCs is on, and whether the connection wires between the main machine and the parallel operation module are correctly connected ...

Mitsubishi servo motors achieve precise positioning Mitsubishi servo motors achieve precise positioning

The servo control system is a process control system that enables the output of the controlled quantity such as the position, direction, and situation of the block to follow the overall goal (or given value) of the input at will. So how does the Mitsubishi servo motor maintain precise positioning, how to look at its closed-loop control characteristics, today ...

Mitsubishi PLC FAQs Mitsubishi PLC FAQs

1. How to connect a PNP three-wire proximity switch to the input port of FX3U PLC. Answer: The signal output termination of the PNP three-wire system close to the switch is connected to the input port of the PLC, such as X0, and the 0V end of the PNP type close switch to the 0V terminal on the PLC, and the S/S terminal and the 0V terminal ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top