Explanation of Mitsubishi pIc source type and drain type Explanation of Mitsubishi pIc source type and drain type

The source type is the power supply of the device, which has an input drive source and an output point with a power supply; Drain type means that the device does not have its own power supply, and the drive of the input point requires an external power supply, and the output is only a passive contact signal. The general input points are ...

How to adjust the jitter phenomenon of Mitsubishi servo motor How to adjust the jitter phenomenon of Mitsubishi servo motor

(1) Prerequisites Mitsubishi servo motors are able to improve the inertia of the motor by adjusting the gain, so as to adapt to the load, but the Mitsubishi servo motor is able to improve endlessly. Under normal circumstances, it is considered that it can withstand within 10-15 times of the additional inertia of the motor, and Mitsubishi reducer is required to be added in addition. We know ...

Mitsubishi servo motors achieve precise positioning Mitsubishi servo motors achieve precise positioning

The servo control system is a process control system that enables the output of the controlled quantity such as the position, direction, and situation of the block to follow the overall goal (or given value) of the input at will. So how does the Mitsubishi servo motor maintain precise positioning, how to look at its closed-loop control characteristics, today ...

Mitsubishi PLC floating-point number comparison and arithmetic instruction usage Mitsubishi PLC floating-point number comparison and arithmetic instruction usage

The floating-point arithmetic instruction (FNC110-FNC1320) is used to process floating-point numbers, which are 32 digits and contain 13 instructions such as floating-point number comparison, transformation, four-rule operation, open-squared operation and trigonometric function. All floating-point processing instructions are 32-bit instructions, and when used ...

Motor speed control through PLC control inverter - Mitsubishi Motor speed control through PLC control inverter - Mitsubishi

1. Press the motor start button, and the motor will start and run at the corresponding speed of 5Hz; After the delay of 10s, the motor will run at the speed corresponding to 10Hz, and after the delay of 10s, the motor will continue to speed up and run at the speed corresponding to 20Hz; In the future, every 10s, the speed law changes, a ...

Mitsubishi inverter encountered problems and solutions Mitsubishi inverter encountered problems and solutions

1. If you want to use the inverter to drive the motor with a capacitor to improve the power factor, but the motor does not move, please explain the reason. The current flowing into the inverter is used to improve the power factor, but the capacitor cannot be started because its charging current causes the inverter overcurrent (OCT), as a countermeasure, ...

Mitsubishi servo motor method Mitsubishi servo motor method

1. Torque control: Torque control sets the output torque of the motor shaft through external imitation input or direct address assignment. For example, 10V is equivalent to 5Nm. When the external analog is set to 5V, the output of the motor shaft is 2.5 Nm. If the motor shaft load is less than 2.5 Nm, when the external load is 2.5 N...

Manipulator Fault Repair - Mitsubishi Robot Manipulator Fault Repair - Mitsubishi Robot

1. Speak before you start With regard to defective electrical equipment, it is necessary not to rush to start, but to inquire about the passage and defective phenomena that cause defects. For unfamiliar equipment, you should also understand the circuit principle and structural characteristics, and follow the corresponding rules. Before dismantling, it is necessary to fully understand each electrical department ...

Mitsubishi PLC and computer communication setup method Mitsubishi PLC and computer communication setup method

After opening the Mitsubishi PLC programming software, select your connection method from the menu "Online" > "Transfer Settings". 1. Connect the Mitsubishi PLC to the computer first. 2. Right-click on "My Computer" and select "Handle"...

Mitsubishi servo motor one-button adjustment function Mitsubishi servo motor one-button adjustment function

In the MR Configurator2 servo commissioning software, Mitsubishi has developed a "one-button adjustment" function to solve the problem of rigid noise of servo motors, as follows: 1. Set PA08 to 0003 and adjust the gain to ...

Advantages and disadvantages of different output types of PLC – Mitsubishi Advantages and disadvantages of different output types of PLC – Mitsubishi

The three output types of PLC are: transistor output, thyristor output and relay output, what is the difference between these three different output types? (1) Transistor output: The big advantage is that it is accustomed to high-frequency action, and the echo time is short, generally about 0.2ms, but ...

Mitsubishi servo motor jog forward and reverse Mitsubishi servo motor jog forward and reverse

Control requirements: press and hold the forward rotation button, the servo motor rotates forward, release the forward rotation button, and the servo motor aborts the work. Press and hold the rotary button, the servo motor rotates, release the rotary button, and the servo motor aborts the work. When turning forward, pressing the turn button has no effect. When turning, pressing the forward turn button is invalid ...

Debugging method of servo motor - Mitsubishi Debugging method of servo motor - Mitsubishi

1. Initialize parameters Before wiring, initialize the parameters. On the control card: select the control method; Reset the PID parameter to zero; When the control card is powered on, the enable signal is closed by default; Save this state to ensure that this is the status when the control card is powered on again. ...

Self-locking function of servo motor - Mitsubishi Self-locking function of servo motor - Mitsubishi

Press the abort button SB1, the contactor KM coil is de-energized, and the auxiliary normally open contact of the KM connected in parallel with SB2 is disconnected to ensure that the KM coil continues to lose power after the button SB1 is released, and the main contact of the KM connected in series in the motor circuit is continuously disconnected and the motor stops. Auxiliary to the KM in parallel with SB2 ...

Classification of Mitsubishi touch screens Classification of Mitsubishi touch screens

At present, Mitsubishi contact screens are generally divided into four categories: resistive contact screens, capacitive contact screens, infrared contact screens and surface acoustic contact screens Mitsubishi servo motors. 1. Resistive contact screen The screen body of the resistive contact screen ...

Electronic gear ratio calculation for Mitsubishi servo motors Electronic gear ratio calculation for Mitsubishi servo motors

When calculating the electronic gear ratio of the Mitsubishi servo motor, the first thing to pay attention to is to check whether your Mitsubishi servo motor has been directly set to XX pulse one turn, if this parameter is not directly set, we can go through a simple formula to calculate the electronic gear ratio of the Mitsubishi servo motor. ...

Mitsubishi PLC writes the holding circuit Mitsubishi PLC writes the holding circuit

There is a very common kind of circuit in Mitsubishi PLC - the persistence circuit. The insistence circuit means that when the external input switch is a button, it can be pressed through the insistence circuit to press the button to insist on the output, similar to the self-locking in the electrical diagram. Let's take Mitsubishi PLC as an example to write a sticking circuit. ...

The role of PLC power module - Mitsubishi The role of PLC power module - Mitsubishi

Internal memory programs, logic operations, sequential manipulation, punctuality, counting, arithmetic operations, and other programmable memories are used to manipulate a variety of machinery or production processes with digital or analog inputs/outputs. PLC-related peripherals should be easy to operate with industry to form a whole, easy to expand...

Seven-step method for PLC project debugging - Mitsubishi PLC Seven-step method for PLC project debugging - Mitsubishi PLC

Many novices in the electrical industry are not sure how to start debugging after completing the planning links such as electrical control cabinets and PLC programs. Perhaps some people due to inappropriate debugging methods have led to PLC burning and other problems, so how should the planned electrical system be debugged? Follow these seven steps. ...

Anti-interference measures for PLCs and touch screens - Mitsubishi PLC Anti-interference measures for PLCs and touch screens - Mitsubishi PLC

1. Select the power supply with excellent performance and press the disturbance introduced by the power grid The power supply of the PLC controller is powered by a non-power line, and is powered by a special line directly led by the main bus of the low-voltage distribution room. Isolation transformer should be selected, the transformer capacity should be 1.2-1.5 times larger than the actual need, and can be used in isolation...

Confirmation and clearing of Mitsubishi inverter alarm history Confirmation and clearing of Mitsubishi inverter alarm history

When the FR-CS80 inverter detects an abnormality, it will display an error message or alarm in the operation panel according to the abnormal content, or maintain the function action and block the output of the inverter. When maintaining a function operation, please deal with the cause of its operation before resetting the inverter, and then start working. ...

Next Page »
CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top